43 research outputs found

    Ferumoxytol-enhanced magnetic resonance angiography for the assessment of potential kidney transplant recipients

    Get PDF
    Objectives: Traditional contrast-enhanced methods for scanning blood vessels using magnetic resonance imaging (MRI) or CT carry potential risks for patients with advanced kidney disease. Ferumoxytol is a superparamagnetic iron oxide nanoparticle preparation that has potential as an MRI contrast agent in assessing the vasculature. Methods: Twenty patients with advanced kidney disease requiring aorto-iliac vascular imaging as part of pre-operative kidney transplant candidacy assessment underwent ferumoxytol-enhanced magnetic resonance angiography (FeMRA) between December 2015 and August 2016. All scans were performed for clinical indications where standard imaging techniques were deemed potentially harmful or inconclusive. Image quality was evaluated for both arterial and venous compartments. Results: First-pass and steady-state FeMRA using incremental doses of up to 4 mg/kg body weight of ferumoxytol as intravenous contrast agent for vascular enhancement was performed. Good arterial and venous enhancements were achieved, and FeMRA was not limited by calcification in assessing the arterial lumen. The scans were diagnostic and all patients completed their studies without adverse events. Conclusions: Our preliminary experience supports the feasibility and utility of FeMRA for vascular imaging in patients with advanced kidney disease due for transplant listing, which has the advantages of obtaining both arteriography and venography using a single test without nephrotoxicity

    Ferumoxytol magnetic resonance angiography: a dose-finding study in patients with chronic kidney disease

    Get PDF
    Objectives: Ferumoxytol is an alternative to gadolinium-based compounds as a vascular contrast agent for magnetic resonance angiography (MRA), particularly for patients with chronic kidney disease (CKD). However, dose-related efficacy data are lacking. We aimed to determine the optimal (minimum effective) dose of ferumoxytol for MRA in patients with CKD. Methods: Ferumoxytol-enhanced MRA (FeMRA) was performed at 3.0 T in patients with CKD after dose increments up to a total of 4 mg/kg. Image quality was assessed by contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) in the abdominal aorta and inferior vena cava. Quadratic regression analyses were performed to estimate the effects of dose increments on CNR and SNR. Results: Twenty-three patients underwent FeMRA (mean age 60 [SD 13] years, 87% men, 48% had diabetic nephropathy) with cumulative doses of 0, 1, 2, 3 and 4 mg/kg of ferumoxytol. On regression analyses, a parabolic relationship was observed between ferumoxytol dose and signal with progressive signal loss using doses exceeding 4 mg/kg. A dose of 3 mg/kg achieved ≥ 75% of predicted peak CNR and SNR and images were deemed of excellent diagnostic quality. Conclusions: In patients with CKD undergoing FeMRA, a dose of 3 mg/kg provides excellent arterial and venous enhancement. The benefits of increasing the dose to a theoretically optimal value of 4 mg/kg appear to be negligible and likely of minimal, if any, diagnostic value

    A national study of autogenous arteriovenous access use and patency in a contemporary hemodialysis population

    Get PDF
    Objective: The predicted outcomes of autogenous arteriovenous (AV) hemodialysis access creation are predominantly based on historical data; however, both the hemodialysis population and clinical practices have changed significantly during the last decade. This study examined contemporary AV access clinical use and patencies. Methods: A multicenter observational cohort study was performed of all new AV accesses created in Scotland in 2015. The primary end point was efficacy assessed by successful AV access use for a minimum of 30 days and primary, primary assisted, and secondary patency at 1 year. Data obtained included all interventions to maintain or to restore patency. Predictors of patency loss including demographics, comorbid conditions, dialysis status, AV access location, duplex ultrasound surveillance, procedures, prior access, and antiplatelets were assessed. Kaplan-Meier and competing risks analyses were performed to estimate the probability of AV access failure. All patients were followed up for at least 1 year or had a censoring event. Results: A total of 582 AV accesses were created in 537 patients (mean age, 60 [standard deviation, 14] years; 60% men; 42% with diabetes) in nine adult renal centers. Mean follow-up was 11.8 (standard deviation, 7.6) months. By the end of the follow-up, 322 (55.3%) AV accesses were successfully used for dialysis. At 1 year, 48% (95% confidence interval [CI], 44-52) of AV accesses had primary patency, (95% CI, 63-71) had primary assisted patency, and 69% (95% CI, 65-73) had secondary patency. The leading cause of primary patency loss was primary failure (30%). An average of 0.48 intervention per patient-year was required to maintain patency. On multivariable analysis, patency was better for an upper arm than for a forearm AV access (1-year secondary patency of upper arm vs forearm AV accesses, 74% vs 58%). The cumulative hazard and incident functions for AV access failure were 31% (95% CI, 27-35) and 23% (95% CI, 20-27) at 1 year, respectively. Conclusions: Despite advances in recent years with preoperative vessel assessment and surveillance, patency rates have not improved, with primary failure remaining the major obstacle. Competing events should be taken into consideration; otherwise, biases may occur with overestimation of the probability of AV access failure

    Validation of a vascular access specific quality of life measure (VASQoL)

    Get PDF
    Background: A self-administered 11 item vascular access specific quality of life measure (VASQoL) was previously derived from detailed qualitative interviews with adult patients with kidney failure who have experienced vascular access using the Capabilities Approach as a theoretical base. This study reports the psychometric validation of the VASQoL measure including its reliability, content validity and responsiveness to change. Methods: Cognitive interviews were conducted with 23 adult patients with kidney failure after completion of the VASQoL measure. Focus group discussion with a vascular access professional multidisciplinary team was undertaken (n = 8) and subsequently a further 101 adult kidney failure patients with vascular access (TCVC, AVF or AVG) completed the digital VASQoL measure, EQ-5D and SF-36 questionnaires in a longitudinal study with prospectively recorded vascular access events. Results: Transcript analysis of cognitive interviews after VASQoL completion indicated that the content was comprehensive and well understood by participants. Assessment of Internal reliability for the VASQoL measure was high (Cronbach’s alpha 0.858). Test-retest reliability of the overall VASQoL measure was high (intra class correlation coefficient 0.916). In those patients who experienced a vascular access event, significant differences were observed in paired analysis of the VASQoL physical domain questions and vascular access function domain questions and in the EQ-5D usual activities, pain and anxiety domains. In those with no vascular access event, variation was observed in longitudinal analysis in VASQoL questions relating to worry about VA function and capability domains, whilst no variation was observed in the EQ5D measure. Conclusion: The VASQoL measure has good internal consistency, test-retest reliability, convergent validity and responsiveness to change for clinically relevant vascular access outcomes. This provides a validated, vascular access specific quality of life measure that can be used in future trials of vascular access, evaluation of new technologies and routine use as a patient reported outcome measure (PROM)

    arteriovenous access graft infection standards of reporting and implications for comparative data analysis

    Get PDF
    Abstract There is presently a lack of organization and standardized reporting schema for arteriovenous graft (AVG) infections. The purpose of this paper is to evaluate the various types of treatment modalities for access site infections through an analysis of current publications on AVG. Key proposals are made to support standardization in a data-driven manner to make infection reporting more uniform and thereby facilitate more meaningful comparisons between various dialysis modalities and AVG technologies

    A national appraisal of haemodialysis vascular access provision in Scotland

    Get PDF
    Purpose: Published registry data demonstrate longstanding variation in the utilisation of different vascular access (VA) modalities between Scottish renal units; this may reflect different clinical processes between centres. A comprehensive appraisal was undertaken to understand the processes underpinning VA creation and maintenance across Scotland. Methods: A mixed methods approach was utilised. Fifty-two semi-structured interviews were conducted with patients and clinicians in all ten, adult and paediatric, Scottish renal units. Interview transcripts were subjected to thematic analysis. Clinical activity data were prospectively collected for six weeks, and correlated with registry data. Results: VA accounts for a large clinical workload. There was significant inter-centre variation in the utilisation of different VA modalities, and patients described frustrating, dissatisfying experiences. VA creation and maintenance pathways functioned best when nephrologists, surgeons and radiologists were co-located on the same campus with close multi-disciplinary working, protected clinical time, and proactive VA maintenance. No unit routinely measured or discussed procedure outcomes or strategic aspects of their service. Conclusions: Varied clinical outcomes reflected varied clinical processes. Optimised clinical pathways, staff education and measurement of clinical outcomes may improve VA service quality and facilitate safer, more effective, patient-centred care

    Identification of molecular markers of delayed graft function based on the regulation of biological ageing

    Get PDF
    Introduction: Delayed graft function is a prevalent clinical problem in renal transplantation for which there is no objective system to predict occurrence in advance. It can result in a significant increase in the necessity for hospitalisation post-transplant and is a significant risk factor for other post-transplant complications. Methodology: The importance of microRNAs (miRNAs), a specific subclass of small RNA, have been clearly demonstrated to influence many pathways in health and disease. To investigate the influence of miRNAs on renal allograft performance post-transplant, the expression of a panel of miRNAs in pre-transplant renal biopsies was measured using qPCR. Expression was then related to clinical parameters and outcomes in two independent renal transplant cohorts. Results: Here we demonstrate, in two independent cohorts of pre-implantation human renal allograft biopsies, that a novel pre-transplant renal performance scoring system (GRPSS), can determine the occurrence of DGF with a high sensitivity (>90%) and specificity (>60%) for donor allografts pre-transplant, using just three senescence associated microRNAs combined with donor age and type of organ donation. Conclusion: These results demonstrate a relationship between pre-transplant microRNA expression levels, cellular biological ageing pathways and clinical outcomes for renal transplantation. They provide for a simple, rapid quantitative molecular pre-transplant assay to determine post-transplant allograft function and scope for future intervention. Furthermore, these results demonstrate the involvement of senescence pathways in ischaemic injury during the organ transplantation process and an indication of accelerated bio-ageing as a consequence of both warm and cold ischaemia

    Digital vs paper data collection : benefits for in-hospital haemodialysis patients

    Get PDF
    Patients on haemodialysis (HD) face complex care pathways, high treatment burden and reduced quality-of-life. A reliable method of assessing and collecting patient-related outcome measures (PROMs) has proven difficult. We asked what the benefits and disadvantages of digital data collection over paper with this population are. Working with multidisciplinary domain experts in the NHS Greater Glasgow and Clyde health board (Scotland) over several iterative development cycles we designed, developed, and evaluate a system with HD patients. A case study was conducted with multidisciplinary experts and patients, using interviews (n=20) combined with the System Usability Scale (n=26). Patients' feedback and system use observations were used to further refine the system design requirements and functionalities. A wide preference for tablet-based input vs paper was noted and self-completed digital data collection overcame situational impairment and promoted patient independence and privacy. Perceived value must be maintained to secure engagement and conventional alternatives offered where appropriate

    Validation of a vascular access specific quality of life measure (VASQoL)

    Get PDF
    Background A self-administered 11 item Vascular Access Specific Quality of Life Measure (VASQoL) was previously derived from detailed qualitative interviews with adult patients with kidney failure who have experienced vascular access using the Capabilities Approach as a theoretical base1. This study reports the psychometric validation of the VASQoL measure including its reliability, content validity and responsiveness to change. Methods Cognitive interviews were conducted with 23 adult patients with kidney failure after completion of the VASQoL measure. Focus group discussion with a vascular access professional multidisciplinary team was undertaken (n=8) and subsequently a further 101 adult kidney failure patients with vascular access (TCVC, AVF or AVG) completed the digital VASQoL measure, EQ-5D and SF-36 questionnaires in a longitudinal study with prospectively recorded vascular access events. Results Transcript analysis of cognitive interviews after VASQoL completion indicated that the content was comprehensive and well understood by participants. Assessment of Internal reliability for the VASQoL measure was high (Cronbach’s alpha 0.858). Test-retest reliability of the overall VASQoL measure was high (intra class correlation coefficient 0.916). In those patients who experienced a vascular access event, significant differences were observed in paired analysis of the VASQoL physical domain questions and vascular access function domain questions and in the EQ-5D usual activities, pain and anxiety domains. In those with no vascular access event, variation was observed in longitudinal analysis in VASQoL questions relating to worry about VA function and capability domains, whilst no variation was observed in the EQ5D measure. Conclusion The VASQoL measure has good internal consistency, test-retest reliability, convergent validity and responsiveness to change for clinically relevant vascular access outcomes. This provides a validated, vascular access specific quality of life measure that can be used in future trials of vascular access, evaluation of new technologies and routine use as a patient reported outcome measure (PROM)
    corecore