21,701 research outputs found
Weakening of the stratospheric polar vortex by Arctic sea-ice loss
Successive cold winters of severely low temperatures in recent years have had critical social and economic impacts on the mid-latitude continents in the Northern Hemisphere. Although these cold winters are thought to be partly driven by dramatic losses of Arctic sea-ice, the mechanism that links sea-ice loss to cold winters remains a subject of debate. Here, by conducting observational analyses and model experiments, we show how Arctic sea-ice loss and cold winters in extra-polar regions are dynamically connected through the polar stratosphere. We find that decreased sea-ice cover during early winter months (November-December), especially over the Barents-Kara seas, enhances the upward propagation of planetary-scale waves with wavenumbers of 1 and 2, subsequently weakening the stratospheric polar vortex in mid-winter (January-February). The weakened polar vortex preferentially induces a negative phase of Arctic Oscillation at the surface, resulting in low temperatures in mid-latitudes.open11167174Ysciescopu
Dimerization-Induced Fermi-Surface Reconstruction in IrTe2
We report a de Haas-van Alphen (dHvA) oscillation study on IrTe2 single crystals showing complex dimer formations. By comparing the angle dependence of dHvA oscillations with band structure calculations, we show distinct Fermi surface reconstruction induced by a 1/5-type and a 1/8-type dimerizations. This verifies that an intriguing quasi-two-dimensional conducting plane across the layers is induced by dimerization in both cases. A phase transition to the 1/8 phase with higher dimer density reveals that local instabilities associated with intra-and interdimer couplings are the main driving force for complex dimer formations in IrTe2.X11149sciescopu
Reduction of Motion Artifacts and Improvement of R Peak Detecting Accuracy Using Adjacent Non-Intrusive ECG Sensors
Non-intrusive electrocardiogram (ECG) monitoring has many advantages: easy to measure and apply in daily life. However, motion noise in the measured signal is the major problem of non-intrusive measurement. This paper proposes a method to reduce the noise and to detect the R peaks of ECG in a stable manner in a sitting arrangement using non-intrusive sensors. The method utilizes two capacitive ECG sensors (cECGs) to measure ECG, and another two cECGs located adjacent to the sensors for ECG are added to obtain the information on motion. Then, active noise cancellation technique and the motion information are used to reduce motion noise. To verify the proposed method, ECG was measured indoors and during driving, and the accuracy of the detected R peaks was compared. After applying the method, the sum of sensitivity and positive predictivity increased 8.39% on average and 26.26% maximally in the data. Based on the results, it was confirmed that the motion noise was reduced and that more reliable R peak positions could be obtained by the proposed method. The robustness of the new ECG measurement method will elicit benefits to various health care systems that require noninvasive heart rate or heart rate variability measurements.1145Ysciescopu
Direct observation of the spin polarization in Au atomic wires on Si(553)
The spin-resolved electronic band structure of Au-induced metallic atomic wires on a vicinal silicon surface, Si(553), was investigated using spin-and angle-resolved photoelectron spectroscopy. We directly measured the spin polarization of three partially filled one-dimensional metallic bands, a one-third-filled band, and the doublet of nearly half-filled bands. For the half-filled doublet, the strong apparent spin polarization was observed near the Fermi energy with a minor out-of-plane spin component. This observation is consistent with the Rashba-type spin-orbit splitting and with a recent experiment on a similar doublet of Si(557)-Au. In contrast, the one-third-filled band does not show a substantial spin polarization within the experimental accuracy, indicating a much smaller spin splitting, if any. These results are discussed for the origin of the partially filled bands and for the intriguing broken-symmetry ground state observed at low temperature.X11116sciescopu
KIAA1114, a full-length protein encoded by the trophinin gene, is a novel surface marker for isolating tumor-initiating cells of multiple hepatocellular carcinoma subtypes
Identification of novel biomarkers for tumor-initiating cells (TICs) is of critical importance for developing diagnostic and therapeutic strategies against cancers. Here we identified the role of KIAA1114, a full-length translational product of the trophinin gene, as a distinctive marker for TICs in human liver cancer by developing a DNA vaccine-induced monoclonal antibody targeting the putative extracellular domain of KIAA1114. Compared with other established markers of liver TICs, KIAA1114 was unique in that its expression was detected in both alpha fetoprotein (AFP)-positive and AFP-negative hepatocellular carcinoma (HCC) cell lines with the expression levels of KIAA1114 being positively correlated to their tumorigenic potentials. Notably, KIAA1114 expression was strongly detected in primary hepatic tumor, but neither in the adjacent non-tumorous tissue from the same patient nor normal liver tissue. KIAA1114(high) cells isolated from HCC cell lines displayed TIC-like features with superior functional and phenotypic traits compared to their KIAA1114(low) counterparts, including tumorigenic abilities in xenotransplantation model, in vitro colony- and spheroid-forming capabilities, expression of stemness-associated genes, and migratory capacity. Our findings not only address the value of a novel antigen, KIAA1114, as a potential diagnostic factor of human liver cancer, but also as an independent biomarker for identifying TIC populations that could be broadly applied to the heterogeneous HCC subtypes.X1110Nsciescopu
Multi-point monitoring of nitrous oxide emissions and aeration efficiency in a full-scale conventional activated sludge tank
In this work the biological tank of a WRRF in Italy was monitored placing five floating hoods on a plug-flow-like biological aerated tank surface in order to capture emission dynamics in both time and space domains. The five hoods report which location is more responsible for N2O production at a certain moment of the day. Moreover, with this experimental investigation, a spatial shift in N2O production towards the end of the biological tank could be detected. This provides important insights in the changes in biological dynamics especially with varying incoming load
Metalorganic vapor-phase epitaxial growth of vertically well-aligned ZnO nanorods
We report metalorganic vapor-phase epitaxial growth and structural and photoluminescent characteristics of ZnO nanorods. The nanorods were grown on Al2O3(00.1) substrates at 400 degreesC without employing any metal catalysts usually needed in other methods. Electron microscopy revealed that nanorods with uniform distributions in their diameters, lengths, and densities were grown vertically from the substrates. The mean diameter of the nanorods is as narrow as 25 nm. In addition, x-ray diffraction measurements clearly show that ZnO nanorods were grown epitaxially with homogeneous in-plane alignment as well as a c-axis orientation. More importantly, from photoluminescence spectra of the nanorods strong and narrow excitonic emission and extremely weak deep level emission were observed, indicating that the nanorods are of high optical quality. (C) 2002 American Institute of Physics.open1110681105sciescopu
Robust Diagnosis Method Based on Parameter Estimation for an Interturn Short-Circuit Fault in Multipole PMSM under High-Speed Operation
This paper proposes a diagnosis method for a multipole permanent magnet synchronous motor (PMSM) under an interturn short circuit fault. Previous works in this area have suffered from the uncertainties of the PMSM parameters, which can lead to misdiagnosis. The proposed method estimates the q-axis inductance (L-q) of the faulty PMSM to solve this problem. The proposed method also estimates the faulty phase and the value of G, which serves as an index of the severity of the fault. The q-axis current is used to estimate the faulty phase, the values of G and L-q. For this reason, two open-loop observers and an optimization method based on a particle-swarm are implemented. The q-axis current of a healthy PMSM is estimated by the open-loop observer with the parameters of a healthy PMSM. The L-q estimation significantly compensates for the estimation errors in high-speed operation. The experimental results demonstrate that the proposed method can estimate the faulty phase, G, and L-q besides exhibiting robustness against parameter uncertainties.1165Ysciescopu
Printing three-dimensional tissue analogues with decellularized extracellular matrix bioink
The ability to print and pattern all the components that make up a tissue (cells and matrix materials) in three dimensions to generate structures similar to tissues is an exciting prospect of bioprinting. However, the majority of the matrix materials used so far for bioprinting cannot represent the complexity of natural extracellular matrix (ECM) and thus are unable to reconstitute the intrinsic cellular morphologies and functions. Here, we develop a method for the bioprinting of cell-laden constructs with novel decellularized extracellular matrix (dECM) bioink capable of providing an optimized microenvironment conducive to the growth of three-dimensional structured tissue. We show the versatility and flexibility of the developed bioprinting process using tissue-specific dECM bioinks, including adipose, cartilage and heart tissues, capable of providing crucial cues for cells engraftment, survival and long-term function. We achieve high cell viability and functionality of the printed dECM structures using our bioprinting method.open11349353sciescopu
Fuzzy Sliding Mode Observer with Grey Prediction for the Estimation of the State-of-Charge of a Lithium-Ion Battery
We propose a state-of-charge (SOC) estimation method for Li-ion batteries that combines a fuzzy sliding mode observer (FSMO) with grey prediction. Unlike the existing methods based on a conventional first-order sliding mode observer (SMO) and an adaptive gain SMO, the proposed method eliminates chattering in SOC estimation. In this method, which uses a fuzzy inference system, the gains of the SMO are adjusted according to the predicted future error and present estimation error of the terminal voltage. To forecast the future error value, a one-step-ahead terminal voltage prediction is obtained using a grey predictor. The proposed estimation method is validated through two types of discharge tests (a pulse discharge test and a random discharge test). The SOC estimation results are compared to the results of the conventional first-order SMO-based and the adaptive gain SMO-based methods. The experimental results show that the proposed method not only reduces chattering, but also improves estimation accuracy.11111Ysciescopu
- …
