361 research outputs found

    A Modified Adaboost Algorithm to Reduce False Positives in Face Detection

    Get PDF
    We present a modified Adaboost algorithm in face detection, which aims at an accurate algorithm to reduce false-positive detection rates. We built a new Adaboost weighting system that considers the total error of weak classifiers and classification probability. The probability was determined by computing both positive and negative classification errors for each weak classifier. The new weighting system gives higher weights to weak classifiers with the best positive classifications, which reduces false positives during detection. Experimental results reveal that the original Adaboost and the proposed method have comparable face detection rate performances, and the false-positive results were reduced almost four times using the proposed method

    Scarred Resonances and Steady Probability Distribution in a Chaotic Microcavity

    Full text link
    We investigate scarred resonances of a stadium-shaped chaotic microcavity. It is shown that two components with different chirality of the scarring pattern are slightly rotated in opposite ways from the underlying unstable periodic orbit, when the incident angles of the scarring pattern are close to the critical angle for total internal reflection. In addition, the correspondence of emission pattern with the scarring pattern disappears when the incident angles are much larger than the critical angle. The steady probability distribution gives a consistent explanation about these interesting phenomena and makes it possible to expect the emission pattern in the latter case.Comment: 4 pages, 5 figure

    The Effects of High-Frequency Transcutaneous Electrical Nerve Stimulation for Dental Professionals with Work-Related Musculoskeletal Disorders: A Single-Blind Randomized Placebo-Controlled Trial

    Get PDF
    Work-related musculoskeletal symptom disorders (WMSDs) have a significant issue for dental professionals. This study investigated the effects of high-frequency transcutaneous electrical nerve stimulation (TENS) on work-related pain, fatigue, and the active range of motion in dental professionals. Among recruited 47 dental professionals with WMSDs, 24 subjects received high-frequency TENS (the TENS group), while 23 subjects received placebo stimulation (the placebo group). TENS was applied to the muscle trigger points of the levator scapulae and upper trapezius, while placebo-TENS was administered without electrical stimulation during 60 min. Pain and fatigue at rest and during movement were assessed using the visual analog scale (VAS), pain pressure threshold (PPT), and active range of motion (AROM) of horizontal head rotation at six time points: prelabor, postlabor, post-TENS, and at 1 h, 3 h, and 1 day after TENS application. Both groups showed significantly increased pain and fatigue and decreased PPT and AROM after completing a work task. The TENS group showed significantly greater improvements in VAS score, fatigue, PPT, and AROM at post-TENS and at 1 h and 3 h after application (all P < 0.05) as compared to the placebo group. A single session high-frequency TENS may immediately reduce symptoms related to WMSDs in dental professionals

    A Strategic Assessment of Needs and Opportunities for the Wider Adoption of Electric Vehicles in Indiana

    Get PDF
    INDOT plans to invest nearly $100 million to build a statewide electric vehicle (EV) charging network as part of the National Electric Vehicle Infrastructure Formula Program. SPR-4509 Phase-I identified energy EV charging deserts in Indiana for long-distance trips. SPR-4509 Phase-II further examines the charging stations\u27 impact on EV long-distance trips in Indiana. Using an agent-based simulation model, the number of charges, vehicle miles traveled, energy used during the trip, and energy used during charging were estimated for nine different cases. High EV daily charging demand areas in Indiana were shown in ArcGIS based on multiple scenarios of different charging station construction phases and EV market penetration rates. The study findings can inform the state’s EV charging plan development

    Evaluation of Left Atrial Volumes Using Multidetector Computed Tomography: Comparison with Echocardiography

    Get PDF
    OBJECTIVE: To prospectively assess the relationship between the two different measurement methods for the evaluation of left atrial (LA) volume using cardiac multidetector computed tomography (MDCT) and to compare the results between cardiac MDCT and echocardiography. MATERIALS AND METHODS: Thirty-five patients (20 men, 15 women; mean age, 60 years) underwent cardiac MDCT angiography for coronary artery disease. The LA volumes were measured using two different methods: the two dimensional (2D) length-based (LB) method measured along the three-orthogonal planes of the LA and the 3D volumetric threshold-based (VTB) method measured according to the threshold 3D segmentation of the LA. The results obtained by cardiac MDCT were compared with those obtained by echocardiography. RESULTS: The LA end-systolic and end-diastolic volumes (LAESV and LAEDV) measured by the 2D-LB method correlated well with those measured by the 3D-VTB method using cardiac MDCT (r = 0.763, r = 0.786, p = 0.001). However, there was a significant difference in the LAESVs between the two measurement methods using cardiac MDCT (p < 0.05). The LAESV measured by cardiac MDCT correlated well with measurements by echocardiography (r = 0.864, p = 0.001), however with a significant difference (p < 0.01) in their volumes. The cardiac MDCT overestimated the LAESV by 22% compared to measurements by echocardiography. CONCLUSION: A significant correlation was found between the two different measurement methods for evaluating LA volumes by cardiac MDCT. Further, cardiac MDCT correlates well with echocardiography in evaluating the LA volume. However, there are significant differences in the LAESV between the two measurement methods using cardiac MDCT and between cardiac MDCT and echocardiographyope

    Proteomic Analysis to Identify Tightly-Bound Cell Wall Protein in Rice Calli.

    Get PDF
    Rice is a model plant widely used for basic and applied research programs. Plant cell wall proteins play key roles in a broad range of biological processes. However, presently, knowledge on the rice cell wall proteome is rudimentary in nature. In the present study, the tightly-bound cell wall proteome of rice callus cultured cells using sequential extraction protocols was developed using mass spectrometry and bioinformatics methods, leading to the identification of 1568 candidate proteins. Based on bioinformatics analyses, 389 classical rice cell wall proteins, possessing a signal peptide, and 334 putative non-classical cell wall proteins, lacking a signal peptide, were identified. By combining previously established rice cell wall protein databases with current data for the classical rice cell wall proteins, a comprehensive rice cell wall proteome, comprised of 496 proteins, was constructed. A comparative analysis of the rice and Arabidopsis cell wall proteomes revealed a high level of homology, suggesting a predominant conservation between monocot and eudicot cell wall proteins. This study importantly increased information on cell wall proteins, which serves for future functional analyses of these identified rice cell wall proteins

    Percutaneous placement of self-expandable metallic stents in patients with obstructive jaundice secondary to metastatic gastric cancer after gastrectomy

    Get PDF
    OBJECTIVE: To evaluate the outcomes of patients undergoing percutaneous placements of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy. MATERIALS AND METHODS: Fifty patients (mean age, 62.4 years; range, 27-86 years) who underwent percutaneous placements of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy were included. The technical success rate, clinical success rate, complication rate, stent patency, patient survival and factors associated with stent patency were being evaluated. RESULTS: The median interval between the gastrectomy and stent placement was 23.1 months (range, 3.9-94.6 months). The 50 patients received a total of 65 stents without any major procedure-related complications. Technical success was achieved in all patients. The mean total serum bilirubin level, which had been 7.19 mg/dL ± 6.8 before stent insertion, decreased to 4.58 mg/dL ± 5.4 during the first week of follow-up (p < 0.001). Clinical success was achieved in 42 patients (84%). Percutaneous transhepatic biliary drainage catheters were removed from 45 patients (90%). Infectious complications were noted in two patients (4%), and stent malfunction occurred in seven patients (14%). The median stent patency was 233 ± 99 days, and the median patient survival was 179 ± 83 days. Total serum bilirubin level after stenting was an independent factor for stent patency (p = 0.009). CONCLUSION: Percutaneous transhepatic placement of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy is a technically feasible and clinically effective palliative procedure
    corecore