216 research outputs found

    Evaluating the miR-302b and miR-145 expression in formalin-fixed paraffin-embedded samples of esophageal squamous cell carcinoma

    Get PDF
    Background: MicroRNAs are involved in key cellular processes regulating, and their misregulation is linked to cancer. The miR-302-367 cluster is exclusively expressed in embryonic stem and carcinoma cells. This cluster also promotes cell reprogramming and stemness process. In contrast, miR-145 is mostly regarded as a tumor suppressor, where it regulates cellular functions such as cell division, differentiation, and apoptosis. By suppressing the main pluripotency factors (OCT4, SOX2, MYC and KLF4), miR-145 silences the self-renewal program in ESCs. Therefore, the main aim of this study is to find a potential link between the expression level of hsa-miR-302b and hsa-miR-145 with tumor vs. non-tumor as well as high-grade vs. low-grade states of the esophageal tissue samples. Methods: A total number of 40 formalin-fixed, paraffin-embedded (FFPE) samples of esophageal squamous-cell carcinoma (ESCC) were obtained, and the tumor and marginal non-tumor areas delineated and punched off by an expert pathologist. Total RNA was extracted with Trizol, and cDNA synthesized using the miRCURY LNA™ Universal RT microRNA PCR Kit. Real-time reverse transcription polymerase chain reaction (RT-PCR) assays were performed using specific LNA-primers and SYBR Green master mix. Results: The expression level of miR-302b failed to show any significant difference, neither between tumor and their non-tumor counterparts, nor among tumors with different grades of malignancies (P > 0.05). In contrast, miR-145 was significantly down regulated in all grades of tumor samples (P 0.05). CONCLUSION: Our data revealed a significant down-regulation of miR-145 in ESCC tissue samples. Based on our ROC curve analysis data (AUC = 0.74, P < 0.001) miR-145 could be regarded as a potential tumor marker for diagnosis of esophageal cancer. © 2015, Academy of Medical Sciences of I.R. Iran. All rights reserved

    Investigating the effects of noise exposure on intensification of diabetes mellitus, serum glucose, cortisol level and body weight of the male mice

    Get PDF
    Noise is considered as one of the harmful factors at industrial environments. It affects human health in different aspects including harmful influences on auditory, vision, neurological and psychiatric systems, hormones, physiological and mental systems. Paying attention to the importance of hormonal effects on human body seems to possess crucial importance. The aim of the present study is to investigate the effects of noise exposure on variation of serum levels of glucose and cortisol at Syrian adult male mouse. 36 Syrian male adult mice were randomly categorized into two experiment and control groups. Garlic powder was added to the mice pelleted food meal (equal to 1% of their daily diet) to study its effect on the cortisol and glucose serum levels. The mice pelleted food contains starch, glucose, isolated soya protein, etc., which are the rich resources of A, C, B1, B2 and B6 vitamins. Streptozotocin (60mg/kg) was injected to the mice at experiment group which were under noise exposure with intensity of 90dB in frequency range of 700-5700Hz. Noise were generated using CoolEdit software and distributed to the fabricated box for 30 days (8h/d).  Fasting cortisol and glucose serum levels were measured for mice of both groups 24h after finishing the exposure period. Results indicated that the glucose serum level in non-diabetic and diabetic subjects under noise exposure had significant difference (p&lt;0.002) with the subjects at control group. Also, cortisol level in non-diabetic and diabetic subjects under noise exposure indicated significant difference (p&lt;0.002) with the subjects at control group. Exposure to noise with intensity of 90dB at frequency range of 700-5700Hz increases the glucose and cortisol serum levels

    Relationship between Vessel Diameter and Time to Maturation of Arteriovenous Fistula for Hemodialysis Access

    Get PDF
    Introduction. Native arteriovenous fistula (AVF) is the recommended vascular access for HD patients by the Dialysis Outcomes Quality Initiative (DOQI) guidelines. The aim of our study was to determine the correlation between diameter and maturation of vessels in radiocephalic AVF. Methods. A prospective cross-sectional study carried out during 2006-2007 on 96 hemodialysis patients from Hasheminejad Kidney Center with non probability selection, all of them with end to side native AVF. Results. In this population 62.5% had wrist (distal radial artery) AVF and 37.5% had antecubital (proximal radial artery) AVF. The mean diameter of artery was 2.57 mm (SD = 1.09) and the mean diameter of vein was 2.40 mm (SD = 0.79). The mean of maturation period was 38.60 days (SD = 42.13). There were no relationship between duration of maturation period and diabetes mellitus, sex, age, diameter of vein and artery (P > 0.05). Period of maturation showed some correlation with the diameter of vein (P = 0.04) in patients with distal radiocephalic fistulae. Conclusions. The maturation of fistula shows correlation with vein diameter, but no correlation was seen with diameter of the arteries. There is much discrepancy between times to maturation in various reports. The average time for fistula maturation was 38/6 days in our study

    Report of 267 Cases of Scorpion Bite Referring to an Emergency Department during One Year

    Get PDF
    Scorpion bite is a common health problem in many parts of the world, including the Iran’s tropics. There are thousands of cases and a number of deaths due to scorpion bite every year in the country. The present study aims to provide further data regarding the details, complications and outcomes of scorpion bite cases referring to Razi Hospital, Ahwaz, from March 2011 to April 2012. A total of 267 patients (56.3% females) with a mean age of 35.2±15.8 years, were included in the study. The most common genus of scorpion involved was Hemiscorpius (69.3%) and the most frequent body part involved was the lower limb (38.9%). The frequency of hemolysis-induced renal insufficiency and death after scorpion bite were 1.9% and 1.1%, respectively. Of all the factors evaluated in this series only the old age was associated with higher possibility of renal insufficiency (P&lt;0.001).

    Intravenous Lidocaine versus Morphine Sulfate in Pain Management for Extremity Fractures; a Clinical Trial

    Get PDF
    Introduction: Considering the existing contradictions regarding effectiveness of intravenous (IV) lidocaine, especially in emergency department (ED), the present study was designed to compare the analgesic effect of IV lidocaine and morphine sulfate in pain management for extremity bone fractures. Method: In this triple blind clinical trial, 15 to 65 year-old patients with extremity fractures and in need of pain management were randomly allocated to either IV lidocaine or morphine sulfate group and were compared regarding severity of pain 5, 10, 15, 20, 25, and 30 minutes after infusion via intention to treat analysis.  The absolute risk reduction, number needed to treat and relative risk of IV lidocaine after 30 minutes were 0.40 (95%CI: 0.25 – 0.64), 7 (95%CI: 3.7 – 23.1), and 20.71 (95%CI: 10.91 – 30.51), respectively. Results: 280 patients with the mean age of 32.50 ± 12.77 years were randomly divided into 2 equal groups of 140 (73.9% male). The 2 groups had similar baseline characteristics. 15 minutes after injection success rate was 49.28% in lidocaine and 33.57% in morphine sulfate group (p = 0.011), and after 30 minutes it reached 85.71% and 65.00%, respectively (p &lt; 0.001). Conclusion: Based on the results of the present study, IV lidocaine could be considered as a reasonable alternative choice for pain management in ED.

    Photochemical of Polychlorinated biphenyl by the photolysis and solvent

    Get PDF
    Polychlorinated biphenyls (PCBs) are one group of persistent organic pollutants (POPs) that are of international concern because of global distribution, persistence, and toxicity. Removal of these compounds from the environment remains a very difficult challenge because the compounds are highly hydrophobic and have very low solubility in water. The photochemical reactor was of annular geometry with a cylindrical low-pressure mercury lamp. The whole Lamp was immersed in a reactor thermostat controlling the temperature at 32 ± 2 °C. The Polychlorinated biphenyls (PCBs) were analyzed by GC/ECD. The degradation of PCBs in terms of one, two and three lamp was 91.9%, 92.7% and 93% respectively. The degradation of PCBs in terms of use of 10% and 20% of total volume of solution of H2O2 were 88.8% and 93% respectively. The degradation of PCBs in terms of ratio to ethanol with oil transformer in 1:1, 2:1 and 3:1 was 83.4%, 92.5% and 93% respectively. The experiments show that UVC-photolysis of H2O2 leads to a degradation efficiency of PCBs in the presence of ethanol. @ JASEMJ. Appl. Sci. Environ. Manage. December, 2010, Vol. 14 (4) 107 - 11

    Effects of N-Acetylcysteine on auditory brainstem response threshold shift in rabbits exposed to noise and carbon monoxide

    Get PDF
    Problem statement: Noise Induced Hearing Loss (NIHL) is one of the most important occupational disease in worldwide. NIHL has been found to be potentiated by simultaneous Carbon monoxide (CO) exposure. Exposure to noise plus CO is common in occupational and environmental settings. Free radicals have been implicated in cochlear damage resulting from exposure to noise and due to CO hypoxia This study examined whether N-Acetylcysteine (NAC) administration cause attenuation of Auditory Brainstem Response (ABR) threshold shifts resulting from noise exposure and noise plus CO exposure. Approach: Forty-two rabbits were divided into seven groups including control, noise+ saline, noise+ CO +saline, noise+ NAC, noise+ CO+ NAC, CO+ NAC and NAC alone. ABR was assessed before exposure, 1 hour and 14 days post exposure. Results: The administration of 325 mg kg-1 of NAC prior, following and post exposure to noise or noise plus CO recovered permanent ABR threshold shift at 1 and 2 kHz almost to the baseline and provided significant attenuation in permanent ABR threshold shift at 4 and 8 kHz in subjects which were exposed to noise but it did not block the potentiating of threshold elevation by CO exposure (extra threshold loss by combined exposure) at 4 and 8 kHz. Conclusion: NAC provides protective effect against hearing loss resulting from noise exposure and simultaneous exposure to noise plus CO. © 2010 Science Publications

    Nonthermal Effects of Radar Exposure on Human: A Review Article

    Get PDF
    ABSTRACT Microwave is part of the electromagnetic spectrum that has different application such as communications, military, air-traffic Control and etc... Previous studies showed that radar frequency could be a health hazard agent. This review article mentioned some of the studies that investigated non-thermal effects of radar frequencies. Reproductive effects, cancers, blood effects, genetic, adverse immune effects and mental effects are non-thermal effects that presented in this report. There are many unknown aspects of the biological effects and many of them did not determined very well such as oxidative stress and mental effects. Compliance with permissible exposure limits, reduction in exposure, and shielding are some of the controlling methods to protect workers from the exposure of microwave and among them, The use of shielding is a superior method for prevention of microwave exposure and among them, electromagnetic Nano composites shields is appropriate for protection of workers from radar exposure

    An attenuation Layer for Electromagnetic Shielding in X- Band Frequency

    Get PDF
    Uncontrolled exposure to X-band frequency leads to health damage. One of the principles of radiation protection is shielding. But, conventional shielding materials have disadvantages. Therefore, studies of novel materials, as an alternative to conventional shielding materials, are required to obtain new electromagnetic shielding material. Therefore, this study investigated the electromagnetic shielding of two component epoxy thermosetting resin for the X - band frequency with workplace approach. Two components of epoxy resin mixed according to manufacturing instruction with the weight ratio that was 100:10 .Epoxy plates fabricated in three different thicknesses (2, 4 and 6mm) and shielding effectiveness measured by Vector Network Analyzer. Then, shielding effectiveness measured by the scattering parameters.The results showed that 6mm thickness of epoxy had the highest and 2mm had the lowest average of shielding effectiveness in X-band frequency that is 4.48 and 1.9 dB, respectively. Also, shielding effectiveness increased by increasing the thickness. But this increasing is useful up to 4mm. Percentage shielding effectiveness of attenuation for 6, 4 and 2mm thicknesses is 64.35%, 63.31% and 35.40%. Also, attenuation values for 4mm and 6mm thicknesses at 8.53 GHz and 8.52 GHz frequency are 77.15% and 82.95%, respectively, and can be used as favourite shields for the above frequency. 4mm-Epoxy is a suitable candidate for shielding application in X-band frequency range but, in the lower section, 6mm thickness is recommended. Finely, the shielding matrix can be used for selecting the proper thickness for electromagnetic shielding in X- Band frequency
    corecore