669 research outputs found

    Spin ordering and electronic texture in the bilayer iridate Sr3_3Ir2_2O7_7

    Full text link
    Through a neutron scattering, charge transport, and magnetization study, the correlated ground state in the bilayer iridium oxide Sr3_3Ir2_2O7_7 is explored. Our combined results resolve scattering consistent with a high temperature magnetic phase that persists above 600 K, reorients at the previously defined TAF=280T_{AF}=280 K, and coexists with an electronic ground state whose phase behavior suggests the formation of a fluctuating charge or orbital phase that freezes below T70T^{*}\approx70 K. Our study provides a window into the emergence of multiple electronic order parameters near the boundary of the metal to insulator phase transition of the 5d Jeff=1/2J_{eff}=1/2 Mott phase.Comment: Revised text and figures. 4 pages, 4 figure

    Reengineering the Glaucoma Quality of Life-15 Questionnaire with Rasch Analysis

    Get PDF
    This article is made available with the permission of the publisher, Association for Research in Vision and OphthalmologyPurpose.: To investigate, using Rasch analysis, whether the 15-item Glaucoma Quality of Life-15 (GQL-15) forms a valid scale and to optimize its psychometric properties. Methods.: One hundred eighteen glaucoma patients (mean age, 65.7 years) completed the German-version of the GQL-15. Rasch analysis was performed to assess category function (how respondents differentiated between the response options), measurement precision (discriminative ability), unidimensionality (whether items measure a single construct), targeting (whether items are of appropriate difficulty for the sample), and differential item functioning (whether comparable subgroups respond differently to an individual item). Where any of these attributes were outside acceptable ranges, steps were taken to improve the instrument. Results.: The five-response categories of the GQL-15 were well differentiated by respondents, as demonstrated by ordered and well-spaced category thresholds. The GQL-15 had an excellent measurement precision but demonstrated poor targeting of item difficulty to person ability and multidimensionality, indicating that it was measuring more than one construct. Removal of six misfitting items created a nine-item unidimensional instrument with good measurement precision and no differential item functioning but poor targeting. A new name, the Glaucoma Activity Limitation (GAL-9) questionnaire, is proposed for the short version, which better reflects the construct under measurement. Conclusions.: The GAL-9 has superior psychometric properties over the GQL-15. Its only limitation is poor targeting of item difficulty to person ability, which is an inevitable attribute of a vision-related activity limitation instrument for glaucoma patients, most of whom have only peripheral visual field defects and little difficulty with daily activities

    Use of multi-criteria analysis (MCA) for supporting community forest management

    Full text link

    Assessing the construct validity of the Quality-of-Life-Aged Care Consumers (QOL-ACC): an aged care-specific quality-of-life measure.

    Full text link
    PURPOSE: To evaluate the construct (convergent and known group) validity of the Quality-of-Life-Aged Care Consumer (QOL-ACC), an older-person-specific quality-of-life measure designed for application in quality assessment and economic evaluation in aged care. METHODS: Convergent validity was assessed by examining relationships with other validated preference-based measures (EQ-5D-5L, ASCOT), quality of aged care experience (QCE-ACC) and life satisfaction (PWI) through an online survey. Known-group validity was assessed by testing the ability to discriminate varying levels of care needs, self-reported health and quality of life. RESULTS: Older people (aged ≥ 65 years) receiving community-aged care (N = 313) responded; 54.6% were female, 41.8% were living alone and 56.8% were receiving higher-level care. The QOL-ACC and its six dimensions were low to moderately and significantly correlated with the EQ-5D-5L (correlation co-efficient range, ρ = 0.39-0.56). The QOL-ACC demonstrated moderate and statistically significant correlations with ASCOT (ρ = 0.61), the QCE-ACC (ρ = 0.51) and the PWI (ρ = 0.70). Respondents with poorer self-reported health status, quality of life and/or higher-level care needs demonstrated lower QOL-ACC scores (P < 0.001), providing evidence of known-group validity. CONCLUSIONS: The study provides evidence of the construct validity of the QOL-ACC descriptive system. A preference-weighted value set is currently being developed for the QOL-ACC, which when finalised will be subjected to further validation assessments

    A retrospective evaluation of the Brain and Body Fitness Studio service on functional capacity and quality of life in people with neurological disorders

    Get PDF
    BackgroundPeople with neurological disorders (ND) are less physically active than the general population due to physical, sensory, and/or cognitive impairments. These individuals often feel intimidated to join mainstream health and wellness centers due to lack of specialized support for people with ND. The Brain and Body Fitness Studio (BBFS) is one of the first Accredited Exercise Physiologist-led interprofessional services in Adelaide South Australia to provide individualized evidence-based multimodal exercise prescription and social support for this population. This comprehensive retrospective study evaluated the impact of BBFS on functional capacity (FC) determined as the 6-min walk distance (6 MWD) achieved during a 6-min walk test (6 MWT), of its members with ND.MethodsSixty-two BBFS members (age, 66 ± 10 years; 60% male) with ND (85% Parkinson's Disease; average time since diagnosis, 4 years [IQR, 2 to 12 years]) and complete pre- and post-6-month clinical assessment of the primary outcome of the study, the 6 MWD, were included in this retrospective analysis. A series of sub-analyses were also performed to investigate the effects of adherence to the recommended prescription of at least twice a week in the program (≥80 vs. &lt; 80% adherence), and disease stage (time since diagnosis; ≥6 vs. &lt; 6 years) on FC.ResultsAlthough there was no statistically significant change in 6 MWD from pre- to post-6-month BBFS program (+15 ± 90 m, p = 0.19), a clinically meaningful improvement of &gt;14 m was evident. Improvement in 6 MWD was significantly greater in members who attended at least 80% of the recommended visits (≥80% visits, +37 ± 58 m; ≤ 80% visits,−1 ± 105 m, p = 0.046). We also found a 6 MWD improvement from pre- to post-6 months in those in the early years of their ND (&lt; 6 years since diagnosis, +39 ± 76 m), but not in those in the later years of their ND (≥6 years since diagnosis, −36 ± 123 m, between group difference, p = 0.029).ConclusionA clinically meaningful 6 MWD improvement may be elicited by services provided by BBFS in people with ND. Overall, the benefits appear to be more evident in members who attended the BBFS for at least 80% of the recommended visits and those who were in the early stage of their ND diagnosis

    Flux quanta driven by high-density currents in low-impurity V3Si and LuNi2B2C: free flux flow and flux-core size effect

    Full text link
    High density direct currents (DC) are used to drive flux quanta via the Lorentz force towards a highly ordered "free flux flow" (FFF) dynamic state, made possible by the weak-pinning environment of high-quality, single-crystal samples of two low-Tc superconducting compounds, V3Si and LuNi2B2C. We report the effect of the magnetic field-dependent fluxon core size on flux flow resistivity rho_f. Much progress has been made in minimizing the technical challenges associated with the use of high currents. Attainment of a FFF phase is indicated by the saturation at highest currents of flux-flow dissipation levels that are well below the normal state resistance and have field-dependent values. The field dependence of the corresponding rho_f is shown to be consistent with a prediction based on a model for the decrease of flux core size at higher fields in weak-coupling BCS s-wave materials.Comment: More empirical treatment of the magnetoresistive correction of V3Si data by additional measurement and analysis (involving two new coauthors, Favreau and Henderson). End result is the same, making for a stronger manuscrip

    Vision in high-level football officials

    Get PDF
    YesOfficiating in football depends, at least to some extent, upon adequate visual function. However, there is no vision standard for football officiating and the nature of the relationship between officiating performance and level of vision is unknown. As a first step in characterising this relationship, we report on the clinically-measured vision and on the perceived level of vision in elite-level, Portuguese football officials. Seventy-one referees (R) and assistant referees (AR) participated in the study, representing 92% of the total population of elite level football officials in Portugal in the 2013/2014 season. Nine of the 22 Rs (40.9%) and ten of the 49 ARs (20.4%) were international-level. Information about visual history was also gathered. Perceived vision was assessed using the preference-values-assigned-to-global-visual-status (PVVS) and the Quality-of-Vision (QoV) questionnaire. Standard clinical vision measures (including visual acuity, contrast sensitivity and stereopsis) were gathered in a subset (n = 44, 62%) of the participants. Data were analysed according to the type (R/AR) and level (international/national) of official, and Bonferroni corrections were applied to reduce the risk of type I errors. Adopting criterion for statistical significance of p<0.01, PVVS scores did not differ between R and AR (p = 0.88), or between national- and international-level officials (p = 0.66). Similarly, QoV scores did not differ between R and AR in frequency (p = 0.50), severity (p = 0.71) or bothersomeness (p = 0.81) of symptoms, or between international-level vs national-level officials for frequency (p = 0.03) or bothersomeness (p = 0.07) of symptoms. However, international-level officials reported less severe symptoms than their national-level counterparts (p<0.01). Overall, 18.3% of officials had either never had an eye examination or if they had, it was more than 3 years previously. Regarding refractive correction, 4.2% had undergone refractive surgery and 23.9% wear contact lenses when officiating. Clinical vision measures in the football officials were similar to published normative values for young, adult populations and similar between R and AR. Clinically-measured vision did not differ according to officiating level. Visual acuity measured with and without a pinhole disc indicated that around one quarter of participants may be capable of better vision when officiating, as evidenced by better acuity (≥1 line of letters) using the pinhole. Amongst the clinical visual tests we used, we did not find evidence for above-average performance in elite-level football officials. Although the impact of uncorrected mild to moderate refractive error upon officiating performance is unknown, with a greater uptake of eye examinations, visual acuity may be improved in around a quarter of officials.Portuguese Foundation for Science and Technology (FCT) in the framework of the Strategic Funding UID/FIS/04650/2013

    Nitrogenase bioelectrocatalysis: heterogeneous ammonia and hydrogen production by MoFe protein

    Get PDF
    notrogenase is the only enzyme known to catalyze the reduction of N2 to 2NH3. In vivo, the MoFe protein component of nitrogenase is exclusively reduced by the ATP-hydrolyzing Fe protein in a series of transient association/dissociation steps that are linked to the hyderolysis of two ATP for each electron transeferred. We report MoFe protein immobilized at an electrode surface, where cobaltocene (as an electron mediator that can be observed in real time at a carbon electrode) is used to reduce the MoFe protein (independent of the Fe protein and of ATP hydrolysis) and support the bioelectrocatalytic reduction of protons to dihydrogen, azide to ammonia, and nitrit to ammonia. Bulk bioelectrosynthetic N3 or NO2 reduction (50 mM) for 30 minutes yielded 70 +- 9 nmol NH3 and 234 +- 62 nmol NH3, with NO2 reduction operating at high faradaic efficiency
    corecore