38 research outputs found

    Amplified Dispersive Fourier-Transform Imaging for Ultrafast Displacement Sensing and Barcode Reading

    Full text link
    Dispersive Fourier transformation is a powerful technique in which the spectrum of an optical pulse is mapped into a time-domain waveform using chromatic dispersion. It replaces a diffraction grating and detector array with a dispersive fiber and single photodetector. This simplifies the system and, more importantly, enables fast real-time measurements. Here we describe a novel ultrafast barcode reader and displacement sensor that employs internally-amplified dispersive Fourier transformation. This technique amplifies and simultaneously maps the spectrally encoded barcode into a temporal waveform. It achieves a record acquisition speed of 25 MHz -- four orders of magnitude faster than the current state-of-the-art.Comment: Submitted to a journa

    Periodically-Poled Silicon [Updated]

    Full text link
    We propose a new class of photonic devices based on periodic stress fields in silicon that enable second-order nonlinearity as well as quasi-phase matching. Periodically-poled silicon (PePSi) adds the periodic poling capability to silicon photonics, and allows the excellent crystal quality and advanced manufacturing capabilities of silicon to be harnessed for devices based on second-order nonlinear effects. As an example of the utility of the PePSi technology, we present simulations showing that mid-wave infrared radiation can be efficiently generated through difference frequency generation from near-infrared with a conversion efficiency of 50%. This technology can also be implemented with piezoelectric material, which offers the capability to dynamically control the X(2) nonlinearity.Comment: 11 pages, 4 figure

    Unveiling multi-scale laser dynamics through time-stretch and time-lens spectroscopies

    Get PDF
    Spectro-temporal studies on the nonlinear physics of complex laser dynamics are essential in approaching its ultimate performance as well as understanding interdisciplinary problems. Unfortunately, it has long been limited by the insufficient spectro-temporal resolving power of conventional temporal and spectral analyzers, particularly when an indefinite optical signal ensemble contains polychromatic mixtures of continuous-wave (CW) and short pulse. In this work, we propose a real-time optical spectro-temporal analyzer (ROSTA) with three synchronized processing channels (i.e., multi-core) for single-shot studies on laser dynamics. It simultaneously provides temporal resolutions of ~70 ps in the time domain and 10’s ns (or 10’s MHz frame rate) in the spectral domain, as well as a high spectral resolution for multiscale optical inputs, i.e., ranging from CW to fs pulses. Its non-trivial record length of up to 6.4 ms enables continuous observations of non-repetitive optical events over an extensive time period ― equivalent to a propagation distance of ~1900 km. To showcase its practical applications, ROSTA is applied to visualize the onset of passive mode-locking of a fiber laser, and interesting phenomena, i.e., evolution from quasi-CW noise burst to strong shock, transition from fluctuation to mode-locking, and coexistence of CW and mode-locked pulses, have been spectro-temporally observed in a single-shot manner for the first time. It is anticipated that ROSTA will be a powerful technology for spectro-temporal optical diagnosis in different areas involving polychromatic transients

    Video-rate centimeter-range optical coherence tomography based on dual optical frequency combs by electro-optic modulators

    Get PDF
    Imaging speed and range are two important parameters for optical coherence tomography (OCT). A conventional video-rate centimeter-range OCT requires an optical source with hundreds of kHz repetition rate and needs the support of broadband detectors and electronics (>1 GHz). In this paper, a type of video-rate centimeter-range OCT system is proposed and demonstrated based on dual optical frequency combs by leveraging electro-optic modulators. The repetition rate difference between dual combs, i.e. the A-scan rate of dual-comb OCT, can be adjusted within 0~6 MHz. By down-converting the interference signal from optical domain to radio-frequency domain through dual comb beating, the down-converted bandwidth of the interference signal is less than 22.5 MHz which is at least two orders of magnitude lower than that in conventional OCT systems. A LabVIEW program is developed for video-rate operation, and the centimeter imaging depth is proved by using 10 pieces of 1-mm thick glass stacked as the sample. The effective beating bandwidth between two optical comb sources is 7 nm corresponding to ~108 comb lines, and the axial resolution of the dual-comb OCT is 158 µm. Dual optical frequency combs provide a promising solution to relax the detection bandwidth requirement in fast long-range OCT systems

    High-contrast, fast chemical imaging by coherent Raman scattering using a self-synchronized two-colour fibre laser

    Get PDF
    Kong C, Pilger C, Hachmeister H, et al. High-contrast, fast chemical imaging by coherent Raman scattering using a self-synchronized two-colour fibre laser. Light: Science &amp; Applications. 2020;9(1): 25.Coherent Raman scattering (CRS) microscopy is widely recognized as a powerful tool for tackling biomedical problems based on its chemically specific label-free contrast, high spatial and spectral resolution, and high sensitivity. However, the clinical translation of CRS imaging technologies has long been hindered by traditional solid-state lasers with environmentally sensitive operations and large footprints. Ultrafast fibre lasers can potentially overcome these shortcomings but have not yet been fully exploited for CRS imaging, as previous implementations have suffered from high intensity noise, a narrow tuning range and low power, resulting in low image qualities and slow imaging speeds. Here, we present a novel high-power self-synchronized two-colour pulsed fibre laser that achieves excellent performance in terms of intensity stability (improved by 50 dB), timing jitter (24.3 fs), average power fluctuation (20 dB) and pulse width variation (<1.8%) over an extended wavenumber range (2700–3550 cm−1). The versatility of the laser source enables, for the first time, high-contrast, fast CRS imaging without complicated noise reduction via balanced detection schemes. These capabilities are demonstrated in this work by imaging a wide range of species such as living human cells and mouse arterial tissues and performing multimodal nonlinear imaging of mouse tail, kidney and brain tissue sections by utilizing second-harmonic generation and two-photon excited fluorescence, which provides multiple optical contrast mechanisms simultaneously and maximizes the gathered information content for biological visualization and medical diagnosis. This work also establishes a general scenario for remodelling existing lasers into synchronized two-colour lasers and thus promotes a wider popularization and application of CRS imaging technologies

    Video-rate centimeter-range optical coherence tomography based on dual optical frequency combs by electro-optic modulators

    Get PDF
    Imaging speed and range are two important parameters for optical coherence tomography (OCT). A conventional video-rate centimeter-range OCT requires an optical source with hundreds of kHz repetition rate and needs the support of broadband detectors and electronics (>1 GHz). In this paper, a type of video-rate centimeter-range OCT system is proposed and demonstrated based on dual optical frequency combs by leveraging electro-optic modulators. The repetition rate difference between dual combs, i.e. the A-scan rate of dual-comb OCT, can be adjusted within 0~6 MHz. By down-converting the interference signal from optical domain to radio-frequency domain through dual comb beating, the down-converted bandwidth of the interference signal is less than 22.5 MHz which is at least two orders of magnitude lower than that in conventional OCT systems. A LabVIEW program is developed for video-rate operation, and the centimeter imaging depth is proved by using 10 pieces of 1-mm thick glass stacked as the sample. The effective beating bandwidth between two optical comb sources is 7 nm corresponding to ~108 comb lines, and the axial resolution of the dual-comb OCT is 158 µm. Dual optical frequency combs provide a promising solution to relax the detection bandwidth requirement in fast long-range OCT systems

    EuniceScope: Low-Cost Imaging Platform for Studying Microgravity Cell Biology

    No full text
    Microgravity is proven to impact a wide range of human physiology, from stimulating stem cell differentiation to confounding cell health in bones, skeletal muscles, and blood cells. The research in this arena is progressively intensified by the increasing promises of human spaceflights. Considering the limited access to spaceflight, ground-based microgravity-simulating platforms have been indispensable for microgravity-biology research. However, they are generally complex, costly, hard to replicate and reconfigure - hampering the broad adoption of microgravity biology and astrobiology. To address these limitations, we developed a low-cost reconfigurable 3D-printed microscope coined EuniceScope to allow the democratization of astrobiology, especially for educational use. EuniceScope is a compact 2D clinostat system integrated with a modularized brightfield microscope, built upon 3D-printed toolbox. We demonstrated that this compact system offers plausible imaging quality and microgravity-simulating performance. Its high degree of reconfigurability thus holds great promise in the wide dissemination of microgravity-cell-biology research in the broader community, including Science, technology, engineering, and mathematics (STEM) educational and scientific community in the future
    corecore