543 research outputs found
Bioresorbable Polylactide Interbody Implants in an Ovine Anterior Cervical Discectomy and Fusion Model: Three-Year Results
Study Design.
In vivo study of anterior discectomy and fusion using a bioresorbable 70:30 poly(l-lactide-co-d,l-lactide) interbody implant in an ovine model.
Objective.
To evaluate the efficacy of the polylactide implant to function as an interbody fusion device, and to assess the tissue reaction to the material during the resorption process.
Summary of Background Data.
The use of polylactide as a cervical interbody implant has several potential advantages when compared with traditional materials. Having an elastic modulus very similar to bone minimizes the potential for stress shielding, and as the material resorbs additional loading is transferred to the developing fusion mass. Although preclinical and clinical studies have demonstrated the suitability of polylactide implants for lumbar interbody fusion, detailed information on cervical anterior cervical discectomy and fusion (ACDF) with polylactide devices is desirable.
Methods.
Single level ACDF was performed in 8 skeletally mature ewes. Bioresorbable 70:30 poly (l-lactide-co-d,l-lactide) interbody implants packed with autograft were used with single-level metallic plates. Radiographs were made every 3 months up to 1 year, and yearly thereafter. The animals were killed at 6 months (3 animals), 12 months (3 animals), and 36 months (2 animals). In addition to the serial plain radiographs, the specimens were evaluated by nondestructive biomechanical testing and undecalcified histologic analysis.
Results.
The bioresorbable polylactide implants were effective in achieving interbody fusion. The 6-month animals appeared fused radiographically and biomechanically, whereas histologic sections demonstrated partial fusion (in 3 of 3 animals). Radiographic fusion was confirmed histologically and biomechanically at 12 months (3 of 3 animals) and 36 months (2 of 2 animals). A mild chronic inflammatory response to the resorbing polylactide implant was observed at both 6 months and 12 months. At 36 months, the operative levels were solidly fused and the implants were completely resorbed. No adverse tissue response was observed in any animal at any time period.
Conclusion.
Interbody fusion was achieved using bioresorbable polylactide implants, with no evidence of implant collapse, extrusion, or adverse tissue response to the material. The use of polylactide as a cervical interbody device appears both safe and effective based on these ACDF animal model results
Radio Planetary Nebulae in the Small Magellanic Cloud
We present ten new radio continuum (RC) detections at catalogued planetary
nebula (PN) positions in the Small Magellanic Cloud (SMC): SMPS6, LIN 41, LIN
142, SMP S13, SMP S14, SMP S16, J18, SMP S18, SMP S19 and SMP S22.
Additionally, six SMC radio PNe previously detected, LIN 45, SMP S11, SMPS17,
LIN321, LIN339 and SMPS24 are also investigated (re-observed) here making up a
population of 16 radio detections of catalogued PNe in the SMC. These 16 radio
detections represent ~15 % of the total catalogued PN population in the SMC. We
show that six of these objects have characteristics that suggest that they are
PN mimics: LIN 41, LIN 45, SMP S11, LIN 142, LIN 321 and LIN 339. We also
present our results for the surface brightness - PN radius relation
({\Sigma}-D) of the SMC radio PN population. These are consistent with previous
SMC and LMC PN measurements of the ({\Sigma}-D) relation.Comment: Accepted for publication in Astrophysics and Space Scienc
Clay Mineral Cycles Identified by Diffuse Spectral Reflectance in Quaternary Sediments From the Northwind Ridge: Implications for Glacial-Interglacial Sedimentation Patterns in the Arctic Ocean
A Quaternary record of fine-grained sediment composition is used to investigate Arctic Ocean climate variability on glacial-interglacial time scales. Diffuse spectral reflectance data from sediment core P1-92AR-P25 from the Northwind Ridge, north of Alaska, demonstrates cyclic variations in mineralogy. Varimax-rotated R-mode factor analysis of down-core data revealed three major mineralogical assemblages, which were then compared with the content of manganese, a proxy for basin ventilation, and thus glacial-interglacial cycles. Results indicate that factor 1, a smectite + chlorite clay assemblage, was delivered to the core site during interglacials, either by fluvial discharge or sea-ice drift from Siberian rivers or inflow from the Bering Sea. Factor 2, an illite + goethite assemblage, is related to glacial periods, and was probably transported from the Laurentide Ice Sheet by icebergs or meltwater. Factor 3, glauconite, might have been sourced from the North Slope region of Alaska during deglacial intervals, or from dolomites associated with Laurentide iceberg-discharge pulses. The observed variations in sediment source and transport mechanisms arise from glacial-interglacial changes in sea level, the size of the terrestrial ice sheets surrounding the Arctic Ocean, the extent of sea-ice cover and altered atmospheric circulation. The reconstructed glacial-interglacial circulation patterns from the Late Quaternary show some similarity with modern circulation changes presumably related to the monthly- to decadally-fluctuating Arctic Oscillation. However, because the Arctic Oscillation operates on much shorter time scales, further research is necessary to better understand the driving mechanism for the changes observed over glacial-interglacial cycles, and the potential role of ocean-atmospheric interaction
Surface transfer doping of diamond: a review
Ultra-wide bandgap materials show great promise as a solution to some of the limitations of current state of the art semiconductor technology. Among these, diamond has exhibited great potential for use in high-power, high-temperature electronics, as well as sensing and quantum applications. Yet, significant challenges associated with impurity doping of the constrained diamond lattice remain a primary impediment towards the development of diamond-based electronic devices. An alternative approach, used with continued success to unlock the use of diamond for semiconductor applications, has been that of ‘surface transfer doping’ - a process by which intrinsically insulating diamond surfaces can be made semiconducting without the need for traditional impurity doping. Here, we present a review of progress in surface transfer doping of diamond, both a history and current outlook of this highly exploitable attribute
Draft genome sequences of two extensively drug-resistant strains of acinetobacter baumannii isolated from clinical samples in Pakistan
Infections in immunocompromised patients that are caused by extensively drug-resistant (XDR) Acinetobacter baumannii strains have been increasingly reported worldwide. In particular, carbapenem-resistant A. baumannii strains are a prominent cause of health care-associated infections. Here, we report draft genome assemblies for two clinical XDR A. baumannii isolates obtained from hospitalized patients in Pakistan
Diel turbidity cycles in a headwater stream: evidence of nocturnal bioturbation?
Purpose: A small number of recent studies have linked daily cycles in stream turbidity to nocturnal bioturbation by aquatic fauna, principally crayfish, and demonstrated this process can significantly impact upon water quality under baseflow conditions. Adding to this limited body of research, we use high-resolution water quality monitoring data to investigate evidence of diel turbidity cycles in a lowland, headwater stream with a known signal crayfish (Pacifastacus leniusculus) population and explore a range of potential causal mechanisms. Materials and methods: Automatic bankside monitoring stations measured turbidity and other water quality parameters at 30-min resolution at three locations on the River Blackwater, Norfolk, UK during 2013. Specifically, we focused on two 20-day periods of baseflow conditions during January and April 2013 which displayed turbidity trends typical of winter and spring seasons, respectively. The turbidity time-series, which were smoothed with 6.5 hour Savitzky-Golay filters to highlight diel trends, were correlated against temperature, stage, dissolved oxygen and pH to assess the importance of abiotic influences on turbidity. Turbidity was also calibrated against suspended particulate matter (SPM) over a wide range of values via linear regression. Results and discussion: Pronounced diel turbidity cycles were found at two of the three sites under baseflow conditions during April. Spring night-time turbidity values consistently peaked between 21:00 and 04:00 with values increasing by ~10 nephelometric turbidity units (NTU) compared with the lowest recorded daytime values which occurred between 10:00 and 14:00. This translated into statistically significant increases in median midnight SPM concentration of up to 76% compared with midday, with night-time (18:00 – 05:30) SPM loads also up to 30% higher than that recorded during the daytime (06:00 – 17:30). Relating turbidity to other water quality parameters exhibiting diel cycles revealed there to be neither any correlation that might indicate a causal link, nor any obvious mechanistic connections to explain the temporal turbidity trends. Diel turbidity cycles were less prominent at all sites during the winter. Conclusions: Considering the seasonality and timing of elevated turbidity, visual observations of crayfish activity, and an absence of mechanistic connections with other water quality parameters, the results presented here are consistent with the hypothesis that nocturnal bioturbation is responsible for generating diel turbidity cycles under baseflow conditions in headwater streams. However, further research in a variety of fluvial environments is required to better assess the spatial extent, importance and causal mechanisms of this phenomenon
Viscoelastic material properties of the peripapillary sclera in normal and early-glaucoma monkey eyes
PURPOSE. To test the hypothesis that changes in the viscoelastic material properties of peripapillary sclera are present within monkey eyes at the onset of early experimental glaucoma detected by confocal scanning laser tomography (CSLT). METHODS. Short-term (3-9 weeks), moderate (Յ44 mm Hg) intraocular pressure (IOP) elevation was induced in one eye of each of eight male monkeys by lasering the trabecular meshwork. This procedure generated early experimental glaucoma, defined as the onset of CSLT-detected optic nerve head (ONH) surface change, in the treated eye. Scleral tensile specimens from the superior and inferior quadrants of the eight earlyglaucoma eyes were subjected to uniaxial stress relaxation and tensile tests to failure and the results compared with similar data obtained in a previous study of 12 normal (nonglaucomatous) eyes. Linear viscoelastic theory was used to characterize viscoelastic material property parameters for each specimen. Differences in each parameter due to quadrant and treatment were assessed by analysis of variance (ANOVA). RESULTS. Peripapillary sclera from the early-glaucoma eyes exhibited an equilibrium modulus (7.46 Ϯ 1.58 MPa) that was significantly greater than that measured in normal eyes (4.94 Ϯ 1.22 MPa; mean Ϯ 95% confidence interval, P Ͻ 0.01, ANOVA). Quadrant differences were not significant for the viscoelastic parameters within each treatment group. CONCLUSIONS. The long-term viscoelastic material properties of monkey peripapillary sclera are altered by exposure to moderate, short-term, chronic IOP elevations and these alterations are present at the onset of CSLT-detected glaucomatous damage to the ONH. Damage to and/or remodeling of the extracellular matrix of these tissues may underlie these changes in scleral material properties. (Invest Ophthalmol Vis Sci. 2005;46: 540 -546 1 The finite element method is a computer-based engineering technique that estimates the stresses (force/cross-sectional area) and strains (local deformation under those stresses) within a complex load-bearing structure. 2 The important aspects of a finite element model are the three-dimensional geometry and material properties of the load-bearing structure and the appropriate boundary and mechanical loading conditions. 2 Within such models of the monkey ONH, scleral material properties are needed to characterize accurately the important transition between the peripapillary sclera and the peripheral laminar beams. To characterize the material properties of peripapillary sclera, we constructed a controlled-environment testing apparatus capable of performing uniaxial biomechanical testing of soft tissues in tension. The overall response of a tissue to a load is the combination of instantaneous (elastic) and time-dependent (viscous) responses, which are governed by its viscoelastic material properties. All soft tissues are viscoelastic, and the characterization of the instantaneous and time-dependent aspects of these material properties is important in understanding a tissue's behavior as a load-bearing structure and its response to short-and long-term changes in the applied load. Accurate characterization of a tissue's material properties can lead to a broader understanding of the mechanisms that underlie tissue damage, as well as determine the resultant altered load-bearing behavior of a remodeled or healed tissue. In a previous report we performed quadrant-based uniaxial tensile testing of peripapillary sclera from normal rabbit and normal monkey eyes 3 and found no differences in the viscoelastic material properties of the peripapillary sclera by quadrant (superior, inferior, nasal, and temporal to the ONH) in either species. In addition, when normal rabbit and monkey sclera were compared with one another, peripapillary sclera from monkey eyes was stiffer and showed slower stress relaxation than sclera from rabbit eyes. The present study tests the hypothesis that changes in the viscoelastic material properties of monkey peripapillary sclera are present at the earliest detectable stage of glaucomatous damage to the ONH, defined as the onset of confocal scanning laser tomography (CSLT)-detected ONH surface change. MATERIALS AND METHODS Animals, Scleral Specimens, and Study Design All animals were treated in accordance with the ARVO Statement for the Use of Animals in Ophthalmic and Vision Research. In the present study, a single scleral tensile specimen was generated from either the superior or inferior quadrant of eight eyes with experimental early glaucoma, yielding four early-glaucoma specimens for each quadrant. Each specimen underwent a multistage uniaxial tensile test. ViscoelasFrom th
SUPPORT-AF: Piloting a Multi-Faceted, Electronic Medical Record-Based Intervention to Improve Prescription of Anticoagulation
Background: Only 50% of eligible atrial fibrillation ( AF ) patients receive anticoagulation ( AC ). Feasibility and effectiveness of electronic medical record (EMR)-based interventions to profile and raise provider AC percentage is poorly understood. The SUPPORT-AF (Supporting Use of AC Through Provider Profiling of Oral AC Therapy for AF) study aims to improve rates of adherence to AC guidelines by developing and delivering supportive tools based on the EMR to providers treating patients with AF.
Methods and Results: We emailed cardiologists and community-based primary care providers affiliated with our institution reports of their AC percentage relative to peers. We also sent an electronic medical record-based message to these providers the day before an appointment with an atrial fibrillation patient who was eligible but not receiving AC . The electronic medical record message asked the provider to discuss AC with the patient if he or she deemed it appropriate. To assess feasibility, we tracked provider review of our correspondence. We also tracked the change in AC for intervention providers relative to alternate primary care providers not receiving our intervention. We identified 3786, 1054, and 566 patients cared for by 49 cardiology providers, 90 community-based primary care providers, and 88 control providers, respectively. At baseline, the percentage of AC was 71.3%, 63.5%, and 58.3% for these 3 respective groups. Intervention providers reviewed our e-mails and electronic medical record messages 45% and 96% of the time, respectively. For providers responding, patient refusal was the most common reason for patients not being on AC (21%) followed by high bleeding risk (19%). At follow-up 10 weeks later, change in AC was no different for either cardiology or community-based primary care providers relative to controls (0.2% lower and 0.01% higher, respectively).
Conclusions: Our intervention profiling AC was feasible, but not sufficient to increase AC in our population
- …