38 research outputs found

    Management recommendations for pancreatic manifestations of von Hippel–Lindau disease

    Get PDF
    Von Hippel–Lindau disease (VHL) is a multineoplasm inherited disease manifesting with hemangioblastoma of the central nervous system and retina, adrenal pheochromocytoma, renal cell carcinoma, pancreatic neuroendocrine tumors and cysts, and neoplasms/cysts of the ear, broad ligament, and testicles. During 2018-2020, the VHL Alliance gathered several committees of experts in the various clinical manifestations of VHL to review the literature, gather the available evidence on VHL, and develop recommendations for patient management. The current report details the results of the discussion of a group of experts in the pancreatic manifestations of VHL along with their proposed recommendations for the clinical surveillance and management of patients with VHL. The recommendations subcommittee performed a comprehensive systematic review of the literature and conducted panel discussions to reach the current recommendations. The level of evidence was defined according to the Shekelle variation of the Grading of Recommendations, Assessment, Development, and Evaluation grading system. The National Comprehensive Cancer Network Categories of Evidence and Consensus defined the committee members' interpretation of the evidence and degree of consensus. The recommendations encompass the main aspects of VHL-related pancreatic manifestations and their clinical management. They are presented in a clinical orientation, including general planning of screening and surveillance for pancreatic neuroendocrine tumors, utility of biochemical biomarkers, the optimal choice for imaging modality, indirect risk stratification, indications for tissue sampling of VHL-related pancreatic neuroendocrine tumors, and interventions. These recommendations are designed to serve as the reference for all aspects of the screening, surveillance, and management of VHL-related pancreatic manifestations

    Reception Test of Petals for the End Cap TEC+ of the CMS Silicon Strip Tracker

    Get PDF
    The silicon strip tracker of the CMS experiment has been completed and was inserted into the CMS detector in late 2007. The largest sub system of the tracker are its end caps, comprising two large end caps (TEC) each containing 3200 silicon strip modules. To ease construction, the end caps feature a modular design: groups of about 20 silicon modules are placed on sub-assemblies called petals and these self-contained elements are then mounted onto the TEC support structures. Each end cap consists of 144 such petals, which were built and fully qualified by several institutes across Europe. Fro

    Integration of the End Cap TEC+ of the CMS Silicon Strip Tracker

    Get PDF
    The silicon strip tracker of the CMS experiment has been completed and inserted into the CMS detector in late 2007. The largest sub-system of the tracker is its end cap system, comprising two large end caps (TEC) each containing 3200 silicon strip modules. To ease construction, the end caps feature a modular design: groups of about 20 silicon modules are placed on sub-assemblies called petals and these self-contained elements are then mounted into the TEC support structures. Each end cap consists of 144 petals, and the insertion of these petals into the end cap structure is referred to as TEC integration. The two end caps were integrated independently in Aachen (TEC+) and at CERN (TEC--). This note deals with the integration of TEC+, describing procedures for end cap integration and for quality control during testing of integrated sections of the end cap and presenting results from the testing

    Procurement for visceral organ transplantation: where to cannulate and how to perfuse?

    Full text link
    PURPOSE OF REVIEW Despite significant improvements in visceral organ transplantation over the last few decades, some technical aspects of organ harvesting remain controversial. The purpose of this article is to review and summarize the latest literature on how to perfuse in multiorgan procurement. RECENT FINDINGS Few prospective studies have analyzed and compared technical aspects of harvesting such as cannulation (aortic-only versus dual aortic and portal flush), flush rates and volumes as well as flush pressures (high pressure vs. gravity). However, these and most data available from additional retrospective and experimental studies do not clearly support one harvesting technique over another. SUMMARY Currently, because of lack of superiority data, no clear guidelines exist on what cannulation techniques to apply during organ procurements in visceral organ transplantation. Additional prospective trials are needed to clarify these questions

    Prognostic criteria for postoperative mortality in 170 patients undergoing major right hepatectomy

    No full text
    Postoperative hepatic failure is a dreadful complication after major hepatectomy and carries high morbidity and mortality rates. In this study, we assessed the accuracy of the 50/50 criteria (bilirubin >2.9 mg/dL and international normalized ratio >1.7 on postoperative day 5) and the Mullen criteria (bilirubin peak >7 mg/dL on postoperative days 1-7) in predicting death from hepatic failure in patients undergoing right hepatectomy only. In addition, we identified prognostic factors linked to intra-hospital morbidity and mortality in these patients

    Prognostic criteria for postoperative mortality in 170 patients undergoing major right hepatectomy

    No full text
    Postoperative hepatic failure is a dreadful complication after major hepatectomy and carries high morbidity and mortality rates. In this study, we assessed the accuracy of the 50/50 criteria (bilirubin >2.9 mg/dL and international normalized ratio >1.7 on postoperative day 5) and the Mullen criteria (bilirubin peak >7 mg/dL on postoperative days 1-7) in predicting death from hepatic failure in patients undergoing right hepatectomy only. In addition, we identified prognostic factors linked to intra-hospital morbidity and mortality in these patients
    corecore