35,399 research outputs found
Multi-community command and control systems in law enforcement: An introductory planning guide
A set of planning guidelines for multi-community command and control systems in law enforcement is presented. Essential characteristics and applications of these systems are outlined. Requirements analysis, system concept design, implementation planning, and performance and cost modeling are described and demonstrated with numerous examples. Program management techniques and joint powers agreements for multicommunity programs are discussed in detail. A description of a typical multi-community computer-aided dispatch system is appended
Measurement of retinal vessel widths from fundus images based on 2-D modeling
Changes in retinal vessel diameter are an important sign of diseases such as hypertension, arteriosclerosis and diabetes mellitus. Obtaining precise measurements of vascular widths is a critical and demanding process in automated retinal image analysis as the typical vessel is only a few pixels wide. This paper presents an algorithm to measure the vessel diameter to subpixel accuracy. The diameter measurement is based on a two-dimensional difference of Gaussian model, which is optimized to fit a two-dimensional intensity vessel segment. The performance of the method is evaluated against Brinchmann-Hansen's half height, Gregson's rectangular profile and Zhou's Gaussian model. Results from 100 sample profiles show that the presented algorithm is over 30% more precise than the compared techniques and is accurate to a third of a pixel
Development of microcomputer-based mental acuity tests for repeated-measures studies
The purpose of this report is to detail the development of the Automated Performance Test System (APTS), a computer battery of mental acuity tests that can be used to assess human performance in the presence of toxic elements and environmental stressors. There were four objectives in the development of APTS. First, the technical requirements for developing APTS followed the tenets of the classical theory of mental tests which requires that tests meet set criteria like stability and reliability (the lack of which constitutes insensitivity). To be employed in the study of the exotic conditions of protracted space flight, a battery with multiple parallel forms is required. The second criteria was for the battery to have factorial multidimensionality and the third was for the battery to be sensitive to factors known to compromise performance. A fourth objective was for the tests to converge on the abilities entailed in mission specialist tasks. A series of studies is reported in which candidate APTS tests were subjected to an examination of their psychometric properties for repeated-measures testing. From this work, tests were selected that possessed the requisite metric properties of stability, reliability, and factor richness. In addition, studies are reported which demonstrate the predictive validity of the tests to holistic measures of intelligence
ICT as learning media and research instrument: What eResearch can offer for those who research eLearning?
Students‘ interactions in digital learning environments are distributed over time and space, and many aspects of eLearning phenomenon cannot be investigated using traditional research approaches. At the same time, the possibility to collect digital data about students‘ online interactions and learning opens a range of new opportunities to use ICT as research tool and apply new research approaches. This symposium brings together some of the recent advancements in the area of ICT-enhanced research and aims to discuss future directions for methodological innovation in this area. The session will include four presentations that will explore different directions of ICT use for eLearning research
Restricted dog leucocyte antigen (DLA) class II haplotypes and genotypes in Beagles
AbstractBeagles are commonly used in vaccine trials as part of the regulatory approval process. Genetic restriction within this breed and the impact this might have on vaccine responses are rarely considered. This study was designed to characterise diversity of dog leucocyte antigen (DLA) class II genes in a breeding colony of laboratory Beagles, whose offspring are used in vaccine studies. DLA haplotypes were determined by PCR and sequence-based typing from genomic DNA extracted from blood. Breeding colony Beagles had significantly different DLA haplotype frequencies in comparison with pet Beagles and both groups showed limited DLA diversity. Restricted DLA class II genetic variability within Beagles might result in selective antigen presentation and vaccine responses that are not necessarily representative of those seen in other dog breeds
Stability, reliability and cross-mode correlations of tests in a recommended 8-minute performance assessment battery
A need exists for an automated performance test system to study drugs, agents, treatments, and stresses of interest to the aviation, space, and environmental medical community. The purpose of this present study is to evaluate tests for inclusion in the NASA-sponsored Automated Performance Test System (APTS). Twenty-one subjects were tested over 10 replications with tests previously identified as good candidates for repeated-measure research. The tests were concurrently administered in paper-and-pencil and microcomputer modes. Performance scores for the two modes were compared. Data from trials 1 to 10 were examined for indications of test stability and reliability. Nine of the ten APT system tests achieved stability. Reliabilities were generally high. Cross-correlation of microbased tests with traditional paper-and-pencil versions revealed similarity of content within tests in the different modes, and implied at least three cognition and two motor factors. This protable, inexpensive, rugged, computerized battery of tests is recommended for use in repeated-measures studies of environmental and drug effects on performance. Identification of other tests compatible with microcomputer testing and potentially capable of tapping previously unidentified factors is recommended. Documentation of APTS sensitivity to environmental agents is available for more than a dozen facilities and is reported briefly. Continuation of such validation remains critical in establishing the efficacy of APTS tests
Searching for "monogenic diabetes" in dogs using a candidate gene approach
BACKGROUND: Canine diabetes is a common endocrine disorder with an estimated breed-related prevalence ranging from 0.005% to 1.5% in pet dogs. Increased prevalence in some breeds suggests that diabetes in dogs is influenced by genetic factors and similarities between canine and human diabetes phenotypes suggest that the same genes might be associated with disease susceptibility in both species. Between 1-5% of human diabetes cases result from mutations in a single gene, including maturity onset diabetes of the adult (MODY) and neonatal diabetes mellitus (NDM). It is not clear whether monogenic forms of diabetes exist within some dog breeds. Identification of forms of canine monogenic diabetes could help to resolve the heterogeneity of the condition and lead to development of breed-specific genetic tests for diabetes susceptibility. RESULTS: Seventeen dog breeds were screened for single nucleotide polymorphisms (SNPs) in eighteen genes that have been associated with human MODY/NDM. Six SNP associations were found from five genes, with one gene (ZFP57) being associated in two different breeds. CONCLUSIONS: Some of the genes that have been associated with susceptibility to MODY and NDM in humans appear to also be associated with canine diabetes, although the limited number of associations identified in this study indicates canine diabetes is a heterogeneous condition and is most likely to be a polygenic trait in most dog breeds. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/2052-6687-1-8) contains supplementary material, which is available to authorized users
Optic nerve head segmentation
Reliable and efficient optic disk localization and segmentation are important tasks in automated retinal screening. General-purpose edge detection algorithms often fail to segment the optic disk due to fuzzy boundaries, inconsistent image contrast or missing edge features. This paper presents an algorithm for the localization and segmentation of the optic nerve head boundary in low-resolution images (about 20 /spl mu//pixel). Optic disk localization is achieved using specialized template matching, and segmentation by a deformable contour model. The latter uses a global elliptical model and a local deformable model with variable edge-strength dependent stiffness. The algorithm is evaluated against a randomly selected database of 100 images from a diabetic screening programme. Ten images were classified as unusable; the others were of variable quality. The localization algorithm succeeded on all bar one usable image; the contour estimation algorithm was qualitatively assessed by an ophthalmologist as having Excellent-Fair performance in 83% of cases, and performs well even on blurred image
Radiation and shielding study for the International Ultraviolet Explorer
Technical advisory services to ensure integrity of parts and material exposed to energetic particle radiation for the IUE scientific instruments, spacecraft, and subsystems are provided. A significant potential for interference, degradation, or failure for unprotected or sensitive items was found. Vulnerable items were identified, and appropriate tests, changes, and shields were defined
A menu of self-administered microcomputer-based neurotoxicology tests
This study examined the feasibility of repeated self-administration of a newly developed battery of mental acuity tests. Researchers developed this battery to be used to screen the fitness for duty of persons in at-risk occupations (astronauts, race car drivers), or those who may be exposed to environmental stress, toxic agents, or disease. The menu under study contained cognitive and motor tests implemented on a portable microcomputer including: a five-test core battery, lasting six minutes, which had demonstrable reliabilities and stability from several previous repeated-measures studies, and also 13 new tests, lasting 42 minutes, which had appeared in other batteries but had not yet been evaluated for repeated-measures implementation in this medium. Sixteen subjects self-administered the battery over 10 repeated sessions. The hardware performed well throughout the study and the tests appeared to be easily self-administered. Stabilities and reliabilities of the test from the core battery were comparable to those obtained previously under more controlled experimental conditions. Analyses of metric properties of the remaining 13 tests produced eight additional tests with satisfactory properties. Although the average retest reliability was high, cross-correlations between tests were low, indicating factorial richness. The menu can be used to form batteries of flexible total testing time which are likely to tap different mental processes and functions
- …