5 research outputs found

    A 0/1h-algorithm using cardiac myosin-binding protein C for early diagnosis of myocardial infarction.

    Get PDF
    AIMS Cardiac myosin-binding protein C (cMyC) demonstrated high diagnostic accuracy for the early detection of non-ST-elevation myocardial infarction (NSTEMI). Its dynamic release kinetics may enable a 0/1h-decision algorithm that is even more effective than the ESC hs-cTnT/I 0/1 h rule-in/rule-out algorithm. METHODS AND RESULTS In a prospective international diagnostic study enrolling patients presenting with suspected NSTEMI to the emergency department, cMyC was measured at presentation and after 1 h in a blinded fashion. Modelled on the ESC hs-cTnT/I 0/1h-algorithms, we derived a 0/1h-cMyC-algorithm. Final diagnosis of NSTEMI was centrally adjudicated according to the 4th Universal Definition of Myocardial Infarction. Among 1495 patients, the prevalence of NSTEMI was 17%. The optimal derived 0/1h-algorithm ruled-out NSTEMI with cMyC 0 h concentration below 10 ng/L (irrespective of chest pain onset) or 0 h cMyC concentrations below 18 ng/L and 0/1 h increase <4 ng/L. Rule-in occurred with 0 h cMyC concentrations of at least 140 ng/L or 0/1 h increase ≥15 ng/L. In the validation cohort (n = 663), the 0/1h-cMyC-algorithm classified 347 patients (52.3%) as 'rule-out', 122 (18.4%) as 'rule-in', and 194 (29.3%) as 'observe'. Negative predictive value for NSTEMI was 99.6% [95% confidence interval (CI) 98.9-100%]; positive predictive value 71.1% (95% CI 63.1-79%). Direct comparison with the ESC hs-cTnT/I 0/1h-algorithms demonstrated comparable safety and even higher triage efficacy using the 0h-sample alone (48.1% vs. 21.2% for ESC hs-cTnT-0/1 h and 29.9% for ESC hs-cTnI-0/1 h; P < 0.001). CONCLUSION The cMyC 0/1h-algorithm provided excellent safety and identified a greater proportion of patients suitable for direct rule-out or rule-in based on a single measurement than the ESC 0/1h-algorithm using hs-cTnT/I. TRIAL REGISTRATION ClinicalTrials.gov number, NCT00470587

    Relevance of platelet desialylation and thrombocytopenia in type 2B von Willebrand disease: preclinical and clinical evidence

    Get PDF
    Patients with type 2B von Willebrand disease (vWD) (caused by gain-of-function mutations in the gene coding for von Willebrand factor) display bleeding to a variable extent and, in some cases, thrombocytopenia. There are several underlying causes of thrombocytopenia in type 2B vWD. It was recently suggested that desialylation-mediated platelet clearance leads to thrombocytopenia in this disease. However, this hypothesis has not been tested in vivo. The relationship between platelet desialylation and the platelet count was probed in 36 patients with type 2B von Willebrand disease (p.R1306Q, p.R1341Q, and p.V1316M mutations) and in a mouse model carrying the severe p.V1316M mutation (the 2B mouse). We observed abnormally high elevated levels of platelet desialylation in both patients with the p.V1316M mutation and the 2B mice. In vitro, we demonstrated that 2B p.V1316M/von Willebrand factor induced more desialylation of normal platelets than wild-type von Willebrand factor did. Furthermore, we found that N-glycans were desialylated and we identified αIIb and β3 as desialylation targets. Treatment of 2B mice with sialidase inhibitors (which correct platelet desialylation) was not associated with the recovery of a normal platelet count. Lastly, we demonstrated that a critical platelet desialylation threshold (not achieved in either 2B patients or 2B mice) was required to induce thrombocytopenia in vivo. In conclusion, in type 2B vWD, platelet desialylation has a minor role and is not sufficient to mediate thrombocytopenia

    A 0/1h-algorithm using cardiac myosin-binding protein C for early diagnosis of myocardial infarction

    Full text link
    AIMS: Cardiac myosin-binding protein C (cMyC) demonstrated high diagnostic accuracy for the early detection of non-ST-elevation myocardial infarction (NSTEMI). Its dynamic release kinetics may enable a 0/1h-decision algorithm that is even more effective than the ESC hs-cTnT/I 0/1 h rule-in/rule-out algorithm. METHODS AND RESULTS: In a prospective international diagnostic study enrolling patients presenting with suspected NSTEMI to the emergency department, cMyC was measured at presentation and after 1 h in a blinded fashion. Modelled on the ESC hs-cTnT/I 0/1h-algorithms, we derived a 0/1h-cMyC-algorithm. Final diagnosis of NSTEMI was centrally adjudicated according to the 4th Universal Definition of Myocardial Infarction. Among 1495 patients, the prevalence of NSTEMI was 17%. The optimal derived 0/1h-algorithm ruled-out NSTEMI with cMyC 0 h concentration below 10 ng/L (irrespective of chest pain onset) or 0 h cMyC concentrations below 18 ng/L and 0/1 h increase <4 ng/L. Rule-in occurred with 0 h cMyC concentrations of at least 140 ng/L or 0/1 h increase ≥15 ng/L. In the validation cohort (n = 663), the 0/1h-cMyC-algorithm classified 347 patients (52.3%) as 'rule-out', 122 (18.4%) as 'rule-in', and 194 (29.3%) as 'observe'. Negative predictive value for NSTEMI was 99.6% [95% confidence interval (CI) 98.9-100%]; positive predictive value 71.1% (95% CI 63.1-79%). Direct comparison with the ESC hs-cTnT/I 0/1h-algorithms demonstrated comparable safety and even higher triage efficacy using the 0h-sample alone (48.1% vs. 21.2% for ESC hs-cTnT-0/1 h and 29.9% for ESC hs-cTnI-0/1 h; P < 0.001). CONCLUSION: The cMyC 0/1h-algorithm provided excellent safety and identified a greater proportion of patients suitable for direct rule-out or rule-in based on a single measurement than the ESC 0/1h-algorithm using hs-cTnT/I. TRIAL REGISTRATION: ClinicalTrials.gov number, NCT00470587
    corecore