77 research outputs found

    Tako-tsubo cardiomyopathy as a recurrent disease with doubtful prognosis of recovery and heterogenic symptoms

    Get PDF
    Tako-tsubo cardiomyopathy, known since 1990, is described as hypo/akinesis of apical heart segments with the hyperkinesis of the basis of the heart which mimics the shape of a traditional Japanese octopus trap. (Cardiol J 2012; 19, 5: 521-523

    Guzy szyi - klasyfikacja, diagnostyka, leczenie

    Get PDF
    W niniejszej pracy przedstawiono problematykę guzów szyi. Zaprezentowano klasyfikację guzów szyi, omówiono metody ich diagnostyki i leczenia

    Copeptin as a Prognostic Marker in Acute Chest Pain and Suspected Acute Coronary Syndrome

    Get PDF
    : Background. In patients admitted with chest pain and suspected acute coronary syndrome (ACS), it is crucial to early identify those who are at higher risk of adverse events. The study aim was to assess the predictive value of copeptin in patients admitted to the emergency department with chest pain and nonconclusive ECG. Methods. Consecutive patients suspected for an ACS were enrolled prospectively. Copeptin and high-sensitive troponin T (hs-TnT) were measured at admission. Patients were followed up at six and 12 months for the occurrence of death and major adverse cardiac and cerebrovascular events (MACCE). Results. Among 154 patients, 11 patients died and 26 experienced MACCE. Mortality was higher in copeptin-positive than copeptin-negative patients with no difference in the rate of MACCE. Copeptin reached the AUC 0.86 (0.75-0.97) for prognosis of mortality at six and 0.77 (0.65-0.88) at 12 months. It was higher than for hs-TnT and their combination at both time points. Copeptin was a strong predictor of mortality in the Cox analysis (HR14.1 at six and HR4.3 at 12 months). Conclusions. Copeptin appears to be an independent predictor of long-term mortality in a selected population of patients suspected for an ACS. The study registration number is ISRCTN14112941

    Zawał serca u chorych bez istotnych zmian w tętnicach wieńcowych

    Get PDF
    Wstęp: Zawał serca u chorych bez istotnych zmian w tętnicach wieńcowych to zagadnienie złożone, o nie do końca wyjaśnionej etiologii, nierzadko przysparzające wielu problemów diagnostycznych. W piśmiennictwie istnieje niewiele danych dotyczących problemu zawału serca z prawidłowym obrazem tętnic wieńcowych oraz odległego rokowania. Celami niniejszej pracy były: określenie odsetka chorych z zawałem serca bez istotnych zmian w tętnicach wieńcowych kierowanych do leczenia inwazyjnego; porównawcza ocena kurczliwości lewej komory w obserwacji wewnątrzszpitalnej i odległej, a także ocena częstości występowania niekorzystnych zdarzeń sercowo-naczyniowych w obserwacji wewnątrzszpitalnej i odległej

    Prohormones in the early diagnosis of cardiac syncope

    Get PDF
    Background--The early detection of cardiac syncope is challenging. We aimed to evaluate the diagnostic value of 4 novel prohormones, quantifying different neurohumoral pathways, possibly involved in the pathophysiological features of cardiac syncope: midregional-pro-A-type natriuretic peptide (MRproANP), C-terminal proendothelin 1, copeptin, and midregionalproadrenomedullin. Methods and Results--We prospectively enrolled unselected patients presenting with syncope to the emergency department (ED) in a diagnostic multicenter study. ED probability of cardiac syncope was quantified by the treating ED physician using a visual analogue scale. Prohormones were measured in a blinded manner. Two independent cardiologists adjudicated the final diagnosis on the basis of all clinical information, including 1-year follow-up. Among 689 patients, cardiac syncope was the adjudicated final diagnosis in 125 (18%). Plasma concentrations of MRproANP, C-terminal proendothelin 1, copeptin, and midregional-proadrenomedullin were all significantly higher in patients with cardiac syncope compared with patients with other causes (P < 0.001). The diagnostic accuracies for cardiac syncope, as quantified by the area under the curve, were 0.80 (95% confidence interval [CI], 0.76-0.84), 0.69 (95% CI, 0.64-0.74), 0.58 (95% CI, 0.52-0.63), and 0.68 (95% CI, 0.63-0.73), respectively. In conjunction with the ED probability (0.86; 95% CI, 0.82-0.90), MRproANP, but not the other prohormone, improved the area under the curve to 0.90 (95% CI, 0.87-0.93), which was significantly higher than for the ED probability alone (P=0.003). An algorithm to rule out cardiac syncope combining an MRproANP level of < 77 pmol/L and an ED probability of < 20% had a sensitivity and a negative predictive value of 99%. Conclusions--The use of MRproANP significantly improves the early detection of cardiac syncope among unselected patients presenting to the ED with syncope

    External Validation and Extension of a Clinical Score for the Discrimination of Type 2 Myocardial Infarction

    Get PDF
    Background: The early non-invasive discrimination of Type 2 versus Type 1 Myocardial Infarction (T2MI, T1MI) is a major unmet clinical need. We aimed to externally validate a recently derived clinical score (Neumann) combing female sex, no radiating chest pain, and high-sensitivity cardiac troponin I (hs-cTnI) concentration ≤40.8 ng/L. Methods: Patients presenting with acute chest discomfort to the emergency department were prospectively enrolled into an international multicenter diagnostic study. The final diagnoses of T2MI and T1MI were centrally adjudicated by two independent cardiologists using all information including cardiac imaging and serial measurements of hs-cTnT/I according to the fourth universal definition of MI. Model performance for T2MI diagnosis was assessed by formal tests and graphical means of discrimination and calibration. Results: Among 6684 enrolled patients, MI was the adjudicated final diagnosis in 1079 (19%) patients, of which 242 (22%) had T2MI. External validation of the Neumann Score showed a moderate discrimination (C-statistic 0.67 (95%CI 0.64–0.71)). Model calibration showed underestimation of the predicted probabilities of having T2MI for low point scores. Model extension by adding the binary variable heart rate >120/min significantly improved model performance (C-statistic 0.73 (95% CI 0.70–0.76, p 120/min improved the model’s performance

    Diagnostic discrimination of a novel high-sensitivity cardiac troponin I assay and derivation/validation of an assay-specific 0/1h-algorithm

    Full text link
    BACKGROUND We aimed to assess the diagnostic utility of the Dimension EXL LOCI High-Sensitivity Troponin I (hs-cTnI-EXL) assay. METHODS This multicenter study included patients with chest discomfort presenting to the emergency department. Diagnoses were centrally and independently adjudicated by two cardiologists using all available clinical information. Adjudication was performed twice including serial measurements of high-sensitivity cardiac troponin (hs-cTn) I-Architect (primary analysis) and serial measurements of hs-cTnT-Elecsys (secondary analysis) in addition to the clinically used (hs)-cTn. The primary objective was to assess and compare the discriminatory performance of hs-cTnI-EXL, hs-cTnI-Architect and hs-cTnT-Elecsys for acute myocardial infarction (MI). Furthermore, we derived and validated a hs-cTnI-EXL-specific 0/1h-algorithm. RESULTS Adjudicated MI was the diagnosis in 204/1454 (14%) patients. The area under the receiver operating characteristics curve for hs-cTnI-EXL was 0.94 (95%CI, 0.93-0.96), and comparable to hs-cTnI-Architect (0.95; 95%CI, 0.93-0.96) and hs-cTnT-Elecsys (0.93; 95%CI, 0.91-0.95). In the derivation cohort (n = 813), optimal criteria for rule-out of MI were 3h) or <9ng/L and 0h-1h-change <5ng/L, and for rule-in ≥160ng/L at presentation or 0h-1h-change ≥100ng/L. In the validation cohort (n = 345), these cut-offs ruled-out 56% of patients (negative predictive value 99.5% (95%CI, 97.1-99.9), sensitivity 97.8% (95%CI, 88.7-99.6)), and ruled-in 9% (positive predictive value 83.3% (95%CI, 66.4-92.7), specificity 98.3% (95%CI, 96.1-99.3)). Secondary analyses using adjudication based on hs-cTnT measurements confirmed the findings. CONCLUSIONS The overall performance of the hs-cTnI-EXL was comparable to best-validated hs-cTnT/I assays and an assay-specific 0/1h-algorithm safely rules out and accurately rules in acute MI. CLINICAL TRIAL REGISTRATION ClinicalTrials.gov number, NCT00470587

    Comparing the utility of clinical risk scores and integrated clinical judgement in patients with suspected acute coronary syndrome

    Full text link
    Aims The utility of clinical risk scores regarding the prediction of major adverse cardiac events (MACE) is uncertain. We aimed to directly compare the prognostic performance of five established clinical risk scores as well as an unstructured integrated clinical judgement (ICJ) of the treating emergency department (ED) physician. Methods and results Thirty-day MACE including all-cause death, life-threatening arrhythmia, cardiogenic shock, acute myocardial infarction (including the index event), and unstable angina requiring urgent coronary revascularization were centrally adjudicated by two independent cardiologists in patients presenting to the ED with acute chest discomfort in an international multicentre study. We compared the prognostic performance of the HEART score, GRACE score, T-MACS, TIMI score, and EDACS, as well as the unstructured ICJ of the treating ED physician (visual analogue scale to estimate the probability of acute coronary syndrome, ranging from 0 to 100). Among 4551 eligible patients, 1110/4551 patients (24.4%) had at least one MACE within 30 days. Prognostic accuracy was high and comparable for the HEART score, GRACE score, T-MACS, and ICJ [area under the receiver operating characteristic curve (AUC) 0.85–0.87] but significantly lower and only moderate for the TIMI score (AUC 0.79, P &lt; 0.001) and EDACS (AUC 0.74, P &lt; 0.001), resulting in sensitivities for the rule-out of 30-day MACE of 93–96, 87 (P &lt; 0.001), and 72% (P &lt; 0.001), respectively. Conclusion The HEART score, GRACE score, T-MACS, and unstructured ICJ of the treating physician, not the TIMI score or EDACS, performed well for the prediction of 30-day MACE and may be considered for routine clinical use. Trial registration ClinicalTrials.gov number NCT0047058
    corecore