183 research outputs found

    Predict-prevent control method for perturbed excitable systems

    Get PDF
    We present a control method based on two steps: prediction and prevention. For prediction we use the anticipated synchronization scheme, considering unidirectional coupling between excitable systems in a master-slave configuration. The master is the perturbed system to be controlled, meanwhile the slave is an auxiliary system which is used to predict the master's behavior. We demonstrate theoretically and experimentally that an efficient control may be achieved.Comment: 4 pages, 5 figure

    Meal rich in rapeseed oil increases 24-h fat oxidation more than meal rich in palm oil

    Get PDF
    The fatty acid composition of the diet has been linked to the prevalence of diabetes and cardiovascular diseases. Compared with monounsaturated fatty acids, saturated fatty acids decrease fat oxidation and diet-induced thermogenesis. A potential limitation of previous studies was the short duration (≦5h) of calorimetry used. The present study compared the effects of a meal rich in saturated and unsaturated fatty acids on 24-h of fat oxidation. Ten males participated in two sessions of indirect calorimetry in a whole-room metabolic chamber. At each session, subjects consumed three meals rich in palm oil (44.3% as saturated, 42.3% as monounsaturated and 13.4% as polyunsaturated fatty acid) or rapeseed oil (11.7% as saturated, 59.3% as monounsaturated and 29.0% as polyunsaturated fatty acid). Fat oxidation over 24-h was significantly higher in the meal rich in rapeseed oil (779 ± 202 kcal/day) than that rich in palm oil (703 ± 158 kcal/day, P < 0.05), although energy expenditure was similar between both meal conditions. Meal rich in unsaturated fatty acids increased the oxidation of exogenous and/or endogenous fat. The results of a long calorimetry period indicate that rapeseed oil offered an advantage toward increased 24-h fat oxidation in healthy young males

    Procjena prijelazne stabilnosti dvopodručnog energetskog sustava s CSC-STATCOM-om zasnovanom na LQR-u

    Get PDF
    A current source converter (CSC) based static synchronous compensator (STATCOM) is a shunt flexible AC transmission system (FACTS) device, which has a vital role as a stability support for small and large transient instability in an interconnected power network. A robust linear quadratic regulator (LQR) based controller for CSC-STATCOM is proposed. In this paper, LQR based CSC-STATCOM is designed to enhance the transient stability of two-area two-machine power system. First of all, modeling &amp; LQR based controller design for CSC-STATCOM are described. After that, the impact of the proposed scheme on the test system with different disturbances is demonstrated. The feasibility of the proposed scheme is demonstrated through simulation in MATLAB and the simulation results show an improvement in the transient stability of power system with CSC-STATCOM. Also, the robustness and effectiveness of CSC-STATCOM are better rather than other shunt FACTS devices (SVC &amp; VSC-STATCOM) in this paper.Statički sinkroni kompenzator (STATCOM) zasnovan na pretvaraču strujnog izvora (CSC) je uređaj za izmjenični prijenos s fleksibilnim "shuntom" (FACTS), koji značajno doprinosi stabilnosti malih i srednjih prijelaznih nestabilnosti u međusobno povezanoj energetskoj mreži. Ovdje je predložen robusni sustav upravljanja zasnovan na linearnom kvadratičnom regulatoru (LQR) za CSC-STATCOM. U ovom radu, CSC-STATCOM zasnovan na LQR-u dizajniran je za povećanje stabilnosti dvopodručnog energetskog sustava s dva motora. Prvo su opisani postupak modeliranja te upravljački sustav zasnovan na LQR-u za CSC-STATCOM. Nakon toga, prikazan je utjecaj predstavljene sheme na ispitni sustav uz prisutnost različitih poremećaja. Provedivost predstavljenog pristupa je prikazana kroz MATLAB simulacije čiji rezultati prikazuju poboljšanje u prijelaznoj stabilnosti energetskog sustava s CSC-STATCOM-om. Također, u ovom radu je prikazana veća robusnost i efikasnost CSC-STATCOM "shunt" FACTS uređaja u odnosu na SVC i VSC-STATCOM
    corecore