15 research outputs found
Exploring the use of internal and externalcontrols for assessing microarray technical performance
<p>Abstract</p> <p>Background</p> <p>The maturing of gene expression microarray technology and interest in the use of microarray-based applications for clinical and diagnostic applications calls for quantitative measures of quality. This manuscript presents a retrospective study characterizing several approaches to assess technical performance of microarray data measured on the Affymetrix GeneChip platform, including whole-array metrics and information from a standard mixture of external spike-in and endogenous internal controls. Spike-in controls were found to carry the same information about technical performance as whole-array metrics and endogenous "housekeeping" genes. These results support the use of spike-in controls as general tools for performance assessment across time, experimenters and array batches, suggesting that they have potential for comparison of microarray data generated across species using different technologies.</p> <p>Results</p> <p>A layered PCA modeling methodology that uses data from a number of classes of controls (spike-in hybridization, spike-in polyA+, internal RNA degradation, endogenous or "housekeeping genes") was used for the assessment of microarray data quality. The controls provide information on multiple stages of the experimental protocol (e.g., hybridization, RNA amplification). External spike-in, hybridization and RNA labeling controls provide information related to both assay and hybridization performance whereas internal endogenous controls provide quality information on the biological sample. We find that the variance of the data generated from the external and internal controls carries critical information about technical performance; the PCA dissection of this variance is consistent with whole-array quality assessment based on a number of quality assurance/quality control (QA/QC) metrics.</p> <p>Conclusions</p> <p>These results provide support for the use of both external and internal RNA control data to assess the technical quality of microarray experiments. The observed consistency amongst the information carried by internal and external controls and whole-array quality measures offers promise for rationally-designed control standards for routine performance monitoring of multiplexed measurement platforms.</p
Quantitative Evidence for Organic Peroxy Radical Photochemistry at 254 nm
Quantitative evidence
is presented for the importance of alkyl
peroxy photochemistry in the formation of secondary organic aerosol
at 254 nm. Particles were generated by extensively oxidizing dodecanoic
acid with photolytically generated hydroxyl radicals in a flow cell.
The resulting particles were collected and analyzed for composition,
which shows a lower contribution from multiply substituted parent
molecules and much more decomposition product than expected from typical
low-NOx oxidation mechanisms. Studies were performed at two separate
reaction times, and kinetics modeling calculations were done using
theoretical work from the combustion literature to estimate the branching
of the photoexcited products. Extrapolation of the ethyl peroxy radical
absorption spectrum compared to actinic flux measurements also shows
that the alkyl peroxy radical absorption at âź310 nm leads to
photochemical lifetimes under pristine tropospheric conditions that
are comparable to predicted lifetimes from peroxyâperoxy recombination
reactions, particularly at higher altitudes
Reference materials for MS-based untargeted metabolomics and lipidomics: a review by the metabolomics quality assurance and quality control consortium (mQACC).
IntroductionThe metabolomics quality assurance and quality control consortium (mQACC) is enabling the identification, development, prioritization, and promotion of suitable reference materials (RMs) to be used in quality assurance (QA) and quality control (QC) for untargeted metabolomics research.ObjectivesThis review aims to highlight current RMs, and methodologies used within untargeted metabolomics and lipidomics communities to ensure standardization of results obtained from data analysis, interpretation and cross-study, and cross-laboratory comparisons. The essence of the aims is also applicable to other 'omics areas that generate high dimensional data.ResultsThe potential for game-changing biochemical discoveries through mass spectrometry-based (MS) untargeted metabolomics and lipidomics are predicated on the evolution of more confident qualitative (and eventually quantitative) results from research laboratories. RMs are thus critical QC tools to be able to assure standardization, comparability, repeatability and reproducibility for untargeted data analysis, interpretation, to compare data within and across studies and across multiple laboratories. Standard operating procedures (SOPs) that promote, describe and exemplify the use of RMs will also improve QC for the metabolomics and lipidomics communities.ConclusionsThe application of RMs described in this review may significantly improve data quality to support metabolomics and lipidomics research. The continued development and deployment of new RMs, together with interlaboratory studies and educational outreach and training, will further promote sound QA practices in the community