51 research outputs found
Atomic layer deposition-based tuning of the pore size in mesoporous thin films studied by in situ grazing incidence small angle x-ray scattering
Atomic layer deposition (ALD) enables the conformal coating of porous
materials, making the technique suitable for pore size tuning at the atomic
level, e.g., for applications in catalysis, gas separation and sensing. It is,
however, not straightforward to obtain information about the conformality of
ALD coatings deposited in pores with diameters in the low mesoporous regime (<
10 nm). In this work, it is demonstrated that in situ synchrotron based grazing
incidence small angle x-ray scattering (GISAXS) can provide valuable
information on the change in density and internal surface area during ALD of
TiO2 in a porous titania film with small mesopores (3-8 nm). The results are
shown to be in good agreement with in situ x-ray fluorescence data representing
the evolution of the amount of Ti atoms deposited in the porous film. Analysis
of both data sets indicates that the minimum pore diameter that can be achieved
by ALD is determined by the size of the Ti-precursor molecule
Osseointegration of a 3D Printed Stemmed Titanium Dental Implant: A Pilot Study
In this pilot study, a 3D printed Grade V titanium dental implant with a novel dual-stemmed design was investigated for its biocompatibility in vivo. Both dual-stemmed (n = 12) and conventional stainless steel conical (n = 4) implants were inserted into the tibial metaphysis of New Zealand white rabbits for 3 and 12 weeks and then retrieved with the surrounding bone, fixed, dehydrated, and embedded into epoxy resin. The implants were analyzed using correlative histology, microcomputed tomography, scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The histological presence of multinucleated osteoclasts and cuboidal osteoblasts revealed active bone remodeling in the stemmed implant starting at 3 weeks and by 12 weeks in the conventional implant. Bone-implant contact values indicated that the stemmed implants supported bone growth along the implant from the coronal crest at both 3- and 12-week time periods and showed bone growth into microporosities of the 3D printed surface after 12 weeks. In some cases, new bone formation was noted in between the stems of the device. Conventional implants showed mechanical interlocking but did have indications of stress cracking and bone debris. This study demonstrates the comparable biocompatibility of these 3D printed stemmed implants in rabbits up to 12 weeks
Recommended from our members
2019 Proceedings of the 2nd International Conference on Trauma Surgery Technology in Giessen (Germany)
It is now for a second time that we can invite researchers to come to Giessen for an international exchange of the latest research and a discussion of ideas. This year again, the Deutsche Forschungsgemeinschaft (DFG) is sponsoring the event. The main topic for 2019 is 'Vibration in antibacterial and oncological therapy'. Many effects of mechanical vibration on tissue have been discovered so far. Clinical applications relying on vibration exist for a variety of conditions. The intracellular processes, however, are still largely not understood. And reproducibility remains a matter of potential for improvement. DFG funds for the 3rd conference in 2020 have already been approved for a focus on multifunctional trauma surgery implants.Deutsche Forschungsgemeischaft (DFG), German
Recommended from our members
2020 Proceedings of the 3rd International Conference on Trauma Surgery Technology in Giessen
The 3
rd event of the Giessen International Conference on Trauma Surgery Technology on
October, the 17th 2020 was hosted on Zoom in accordance with the worldwide corona
situation. Dr Mieczakowski, Dr Yu, and Wolfram drafted in 2018 from Jan’s apartment in Bremen the
manuscript which was submitted to and approved for funding by the Deutsche
Forschungsgemeinschaft (DFG). At that time, we had no idea what substantial changes the
conferencing concept would require. This is why we would like to thank again Michele. She first
planned this year’s event after the 2019 date and then in the spring of 2020 had to replan for the
new situation
Nanoscale Osseointegration : Characterization of Biomaterials and their Interfaces with Electron Tomography
Bone response is one of the key determining factors in the overall success of biomaterials intended for bone regeneration and osseointegration. Understanding the formation of bone at an implant surface may lead to the improved design of biomaterials for the future. However, due to the inhomogeneity of bone tissue at an interface, two-dimensional images often lack detail on the interfacial complexity. Furthermore, the increasing use of nanotechnology in the design and production of biomaterials demands characterization techniques on a similar nano length scale. While current analysis methods, such as X-ray tomography, transmission electron microscopy, focused ion beam microscopy and scanning electron microscopy, provide a basis for analysing biomaterials and biointerfaces, they are incapable of doing so with both nanometre resolution and three-dimensional clarity. In contrast, electron tomography may be used to characterize the three-dimensional structure of biomaterials and their interfaces to bone with nanometre resolution. In this work, hydroxyapatite scaffolds, and laser-modified titanium and Ti6Al4V implants were studied in contact with human or rabbit bone. Z-contrast electron tomography revealed that the orientation of collagen in bone apposing hydroxyapatite, titanium and Ti6Al4V implants is consistently parallel to the implant surface, where the bioactive layer that precipitates on HA is oriented perpendicular to the implant surface. With this method, complete three-dimensional nanoscale osseointegration of titanium-based implants was also established. The extension of this technique from interfacial analyses to the design of biomaterials provided an understanding of the pore structure of mesoporous titania. In further investigations, the open three-dimensional pore network, as revealed by electron tomography, showed promise as a coating that improves implant osseointegration and enables site-specific drug-delivery from an implant surface. In summary, it was demonstrated that two-dimensional characterization techniques were insufficient for the investigation of nanostructured biomaterials, as well as their interfaces to bone. Visualizing biointerfaces and biomaterials with nanometre precision in three-dimensions can expose new fundamental information on materials properties and bone response, enabling better design of biomaterials for the future
Nanoscale Osseointegration : Characterization of Biomaterials and their Interfaces with Electron Tomography
Bone response is one of the key determining factors in the overall success of biomaterials intended for bone regeneration and osseointegration. Understanding the formation of bone at an implant surface may lead to the improved design of biomaterials for the future. However, due to the inhomogeneity of bone tissue at an interface, two-dimensional images often lack detail on the interfacial complexity. Furthermore, the increasing use of nanotechnology in the design and production of biomaterials demands characterization techniques on a similar nano length scale. While current analysis methods, such as X-ray tomography, transmission electron microscopy, focused ion beam microscopy and scanning electron microscopy, provide a basis for analysing biomaterials and biointerfaces, they are incapable of doing so with both nanometre resolution and three-dimensional clarity. In contrast, electron tomography may be used to characterize the three-dimensional structure of biomaterials and their interfaces to bone with nanometre resolution. In this work, hydroxyapatite scaffolds, and laser-modified titanium and Ti6Al4V implants were studied in contact with human or rabbit bone. Z-contrast electron tomography revealed that the orientation of collagen in bone apposing hydroxyapatite, titanium and Ti6Al4V implants is consistently parallel to the implant surface, where the bioactive layer that precipitates on HA is oriented perpendicular to the implant surface. With this method, complete three-dimensional nanoscale osseointegration of titanium-based implants was also established. The extension of this technique from interfacial analyses to the design of biomaterials provided an understanding of the pore structure of mesoporous titania. In further investigations, the open three-dimensional pore network, as revealed by electron tomography, showed promise as a coating that improves implant osseointegration and enables site-specific drug-delivery from an implant surface. In summary, it was demonstrated that two-dimensional characterization techniques were insufficient for the investigation of nanostructured biomaterials, as well as their interfaces to bone. Visualizing biointerfaces and biomaterials with nanometre precision in three-dimensions can expose new fundamental information on materials properties and bone response, enabling better design of biomaterials for the future
Nanoscale Osseointegration : Characterization of Biomaterials and their Interfaces with Electron Tomography
Bone response is one of the key determining factors in the overall success of biomaterials intended for bone regeneration and osseointegration. Understanding the formation of bone at an implant surface may lead to the improved design of biomaterials for the future. However, due to the inhomogeneity of bone tissue at an interface, two-dimensional images often lack detail on the interfacial complexity. Furthermore, the increasing use of nanotechnology in the design and production of biomaterials demands characterization techniques on a similar nano length scale. While current analysis methods, such as X-ray tomography, transmission electron microscopy, focused ion beam microscopy and scanning electron microscopy, provide a basis for analysing biomaterials and biointerfaces, they are incapable of doing so with both nanometre resolution and three-dimensional clarity. In contrast, electron tomography may be used to characterize the three-dimensional structure of biomaterials and their interfaces to bone with nanometre resolution. In this work, hydroxyapatite scaffolds, and laser-modified titanium and Ti6Al4V implants were studied in contact with human or rabbit bone. Z-contrast electron tomography revealed that the orientation of collagen in bone apposing hydroxyapatite, titanium and Ti6Al4V implants is consistently parallel to the implant surface, where the bioactive layer that precipitates on HA is oriented perpendicular to the implant surface. With this method, complete three-dimensional nanoscale osseointegration of titanium-based implants was also established. The extension of this technique from interfacial analyses to the design of biomaterials provided an understanding of the pore structure of mesoporous titania. In further investigations, the open three-dimensional pore network, as revealed by electron tomography, showed promise as a coating that improves implant osseointegration and enables site-specific drug-delivery from an implant surface. In summary, it was demonstrated that two-dimensional characterization techniques were insufficient for the investigation of nanostructured biomaterials, as well as their interfaces to bone. Visualizing biointerfaces and biomaterials with nanometre precision in three-dimensions can expose new fundamental information on materials properties and bone response, enabling better design of biomaterials for the future
- …