    A novel method for measuring bowel motility and velocity with dynamic magnetic resonance imaging in two and three dimensions

    Get PDF
    Increasingly, dynamic MRI has potential as a non-invasive and accessible tool for diagnosing and monitoring gastrointestinal motility in healthy and diseased bowel. However, current MRI methods of measuring bowel motility have limitations: requiring bowel preparation or long acquisition times; providing mainly surrogate measures of motion; and estimating bowel-wall movement in just two dimensions. In this proof-of-concept study we apply a method that provides a quantitative measure of motion within the bowel, in both 2D and 3D, using existing, vendor-implemented MRI pulse sequences with minimal bowel-preparation. This method uses a minimised cost function to fit linear vectors in the spatial and temporal domains. It is sensitised to the spatial scale of the bowel and aims to address issues relating to the low signal-to-noise in high-temporal resolution dynamic MRI scans, previously compensated for by performing thick-slice (10 mm) 2D coronal scans. We applied both 2D and 3D scanning protocols in two healthy volunteers. For 2D scanning, analysis yielded bi-modal velocity peaks, with a mean antegrade motion of 5.5 mm/s and an additional peak at ~9 mm/s corresponding to longitudinal peristalsis, as supported by intra-operative data from the literature. Furthermore, 3D scans indicated a mean forward motion of 4.7 mm/s, and degrees of ante- and retrograde motion were also established. These measures show promise for the non-invasive assessment of bowel motility, and have the potential to be tuned to particular regions of interest and behaviours within the bowel

    Validation of left atrial volume correction for single plane method on four-chamber cine cardiac MRI

    Get PDF
    Background: Left atrial (LA) assessment is an important marker of adverse cardiovascular outcomes. Cardiovascular magnetic resonance (CMR) accurately quantifies LA volume and function based on biplane long-axis imaging. We aimed to validate single-plane-derived LA indices against the biplane method to simplify the post-processing of cine CMR. Methods: In this study, 100 patients from Leeds Teaching Hospitals were used as the derivation cohort. Bias correction for the single plane method was applied and subsequently validated in 79 subjects. Results: There were significant differences between the biplane and single plane mean LA maximum and minimum volumes and LA ejection fraction (EF) (all p < 0.01). After correcting for biases in the validation cohort, significant correlations in all LA indices were observed (0.89 to 0.98). The area under the curve (AUC) for the single plane to predict biplane cutoffs of LA maximum volume ≥ 112 mL was 0.97, LA minimum volume ≥ 44 mL was 0.99, LA stroke volume (SV) ≤ 21 mL was 1, and LA EF ≤ 46% was 1, (all p < 0.001). Conclusions: LA volumetric and functional assessment by the single plane method has a systematic bias compared to the biplane method. After bias correction, single plane LA volume and function are comparable to the biplane method

    Kat-ARC accelerated 4D flow CMR: clinical validation for transvalvular flow and peak velocity assessment

    Get PDF
    Background: To validate the k-adaptive-t autocalibrating reconstruction for Cartesian sampling (kat-ARC), an exclusive sparse reconstruction technique for four-dimensional (4D) flow cardiac magnetic resonance (CMR) using conservation of mass principle applied to transvalvular flow.   Methods: This observational retrospective study (2020/21-075) was approved by the local ethics committee at the University of East Anglia. Consent was waived. Thirty-five patients who had a clinical CMR scan were included. CMR protocol included cine and 4D flow using Kat-ARC acceleration factor 6. No respiratory navigation was applied. For validation, the agreement between mitral net flow (MNF) and the aortic net flow (ANF) was investigated. Additionally, we checked the agreement between peak aortic valve velocity derived by 4D flow and that derived by continuous-wave Doppler echocardiography in 20 patients.   Results: The median age of our patient population was 63 years (interquartile range [IQR] 54–73), and 18/35 (51%) were male. Seventeen (49%) patients had mitral regurgitation, and seven (20%) patients had aortic regurgitation. Mean acquisition time was 8 ± 4 min. MNF and ANF were comparable: 60 mL (51−78) versus 63 mL (57−77), p = 0.310). There was an association between MNF and ANF (rho = 0.58, p < 0.001). Peak aortic valve velocity by Doppler and 4D flow were comparable (1.40 m/s, [1.30−1.75] versus 1.46 m/s [1.25−2.11], p = 0.602) and also correlated with each other (rho = 0.77, p < 0.001).   Conclusions: Kat-ARC accelerated 4D flow CMR quantified transvalvular flow in accordance with the conservation of mass principle and is primed for clinical translation

    Development and validation of AI-derived segmentation of four-chamber cine cardiac magnetic resonance

    Get PDF
    Background: Cardiac magnetic resonance (CMR) in the four-chamber plane offers comprehensive insight into the volumetrics of the heart. We aimed to develop an artificial intelligence (AI) model of time-resolved segmentation using the four-chamber cine.   Methods: A fully automated deep learning algorithm was trained using retrospective multicentre and multivendor data of 814 subjects. Validation, reproducibility, and mortality prediction were evaluated on an independent cohort of 101 subjects.   Results: The mean age of the validation cohort was 54 years, and 66 (65%) were males. Left and right heart parameters demonstrated strong correlations between automated and manual analysis, with a ρ of 0.91−0.98 and 0.89−0.98, respectively, with minimal bias. All AI four-chamber volumetrics in repeatability analysis demonstrated high correlation (ρ = 0.99−1.00) and no bias. Automated four-chamber analysis underestimated both left ventricular (LV) and right ventricular (RV) volumes compared to ground-truth short-axis cine analysis. Two correction factors for LV and RV four-chamber analysis were proposed based on systematic bias. After applying the correction factors, a strong correlation and minimal bias for LV volumetrics were observed. During a mean follow-up period of 6.75 years, 16 patients died. On stepwise multivariable analysis, left atrial ejection fraction demonstrated an independent association with death in both manual (hazard ratio (HR) = 0.96, p = 0.003) and AI analyses (HR = 0.96, p < 0.001).   Conclusion: Fully automated four-chamber CMR is feasible, reproducible, and has the same real-world prognostic value as manual analysis. LV volumes by four-chamber segmentation were comparable to short-axis volumetric assessment

    Automated 4D flow cardiac MRI pipeline to derive peak mitral inflow diastolic velocities using short-axis cine stack: Two centre validation study against echocardiographic pulse-wave doppler

    Get PDF
    Background: Measurement of peak velocities is important in the evaluation of heart failure. This study compared the performance of automated 4D flow cardiac MRI (CMR) with traditional transthoracic Doppler echocardiography (TTE) for the measurement of mitral inflow peak diastolic velocities. Methods: Patients with Doppler echocardiography and 4D flow cardiac magnetic resonance data were included retrospectively. An established automated technique was used to segment the left ventricular transvalvular flow using short-axis cine stack of images. Peak mitral E-wave and peak mitral A-wave velocities were automatically derived using in-plane velocity maps of transvalvular flow. Additionally, we checked the agreement between peak mitral E-wave velocity derived by 4D flow CMR and Doppler echocardiography in patients with sinus rhythm and atrial fibrillation (AF) separately. Results: Forty-eight patients were included (median age 69 years, IQR 63 to 76; 46% female). Data were split into three groups according to heart rhythm. The median peak E-wave mitral inflow velocity by automated 4D flow CMR was comparable with Doppler echocardiography in all patients (0.90 ± 0.43 m/s vs 0.94 ± 0.48 m/s, P = 0.132), sinus rhythm-only group (0.88 ± 0.35 m/s vs 0.86 ± 0.38 m/s, P = 0.54) and in AF-only group (1.33 ± 0.56 m/s vs 1.18 ± 0.47 m/s, P = 0.06). Peak A-wave mitral inflow velocity results had no significant difference between Doppler TTE and automated 4D flow CMR (0.81 ± 0.44 m/s vs 0.81 ± 0.53 m/s, P = 0.09) in all patients and sinus rhythm-only groups. Automated 4D flow CMR showed a significant correlation with TTE for measurement of peak E-wave in all patients group (r=0.73, P<0.001) and peak A-wave velocities (r=0.88, P<0.001). Moreover, there was a significant correlation between automated 4D flow CMR and TTE for peak-E wave velocity in sinus rhythm-only patients (r=0.68, P<0.001) and AF-only patients (r=0.81, P=0.014). Excellent intra-and inter-observer variability was demonstrated for both parameters. Conclusion: Automated dynamic peak mitral inflow diastolic velocity tracing using 4D flow CMR is comparable to Doppler echocardiography and has excellent repeatability for clinical use. However, 4D flow CMR can potentially underestimate peak velocity in patients with AF

    Aortic flow is abnormal in HFpEF

    Get PDF
    Aims: Turbulent aortic flow makes the cardiovascular system less effective. It remains unknown if patients with heart failure with preserved ejection fraction (HFpEF) have disturbed aortic flow. This study sought to investigate advanced markers of aortic flow disturbances in HFpEF. Methods: This case-controlled observational study used four-dimensional flow cardiovascular magnetic resonance derived, two-dimensional phase-contrast reformatted plane data at an orthogonal plane just above the sino-tubular junction. We recruited 10 young healthy controls (HCs), 10 old HCs and 23 patients with HFpEF. We analysed average systolic aortic flow displacement (FDsavg), systolic flow reversal ratio (sFRR) and pulse wave velocity (PWV). In a sub-group analysis, we compared old HCs versus age-gender-matched HFpEF (N=10). Results: Differences were significant in mean age (P 17.7% achieved 74% sensitivity, 70% specificity for differentiating them. sFRR was notably higher in HFpEF (11±10% vs 7±6%, P 7.3% yielded 78% sensitivity, 70% specificity in differentiating these groups. In sub-group analysis, FDsavg remained distinctly elevated in HFpEF (22.4±9.7% vs 16±4.9%, P=0.029). FDsavg of >16% showed 100% sensitivity and 70% specificity (P=0.01). Similarly, sFRR remained significantly higher in HFpEF (11.3±9.5% vs 6.6±6.4%, P=0.007). A sFRR of >7.2% showed 100% sensitivity and 60% specificity (P<0.001). Conclusion: Aortic flow haemodynamics namely FDsavg and sFRR are significantly affected in ageing and HFpEF patients

    Cardiac magnetic resonance modelling of systolic and diastolic blood pressure

    Get PDF
    Aims: Blood pressure (BP) is a crucial factor in cardiovascular health and can affect cardiac imaging assessments. However, standard outpatient cardiovascular MR (CMR) imaging procedures do not typically include BP measurements prior to image acquisition. This study proposes that brachial systolic BP (SBP) and diastolic BP (DBP) can be modelled using patient characteristics and CMR data. Methods: In this multicentre study, 57 patients from the PREFER-CMR registry and 163 patients from other registries were used as the derivation cohort. All subjects had their brachial SBP and DBP measured using a sphygmomanometer. Multivariate linear regression analysis was applied to predict brachial BP. The model was subsequently validated in a cohort of 169 healthy individuals. Results: Age and left ventricular ejection fraction were associated with SBP. Aortic forward flow, body surface area and left ventricular mass index were associated with DBP. When applied to the validation cohort, the correlation coefficient between CMR-derived SBP and brachial SBP was (r=0.16, 95% CI 0.011 to 0.305, p=0.03), and CMR-derived DBP and brachial DBP was (r=0.27, 95% CI 0.122 to 0.403, p=0.0004). The area under the curve (AUC) for CMR-derived SBP to predict SBP>120 mmHg was 0.59, p=0.038. Moreover, CMR-derived DBP to predict DBP>80 mmHg had an AUC of 0.64, p=0.002. Conclusion: CMR-derived SBP and DBP models can estimate brachial SBP and DBP. Such models may allow efficient prospective collection, as well as retrospective estimation of BP, which should be incorporated into assessments due to its critical effect on load-dependent parameters

    Validation of 2D flow MRI for helical and vortical flows

    Get PDF
    Purpose The main objective of this study was to develop two-dimensional (2D) phase contrast (PC) methods to quantify the helicity and vorticity of blood flow in the aortic root. Methods This proof-of-concept study used four-dimensional (4D) flow cardiovascular MR (4D flow CMR) data of five healthy controls, five patients with heart failure with preserved ejection fraction and five patients with aortic stenosis (AS). A PC through-plane generated by 4D flow data was treated as a 2D PC plane and compared with the original 4D flow. Visual assessment of flow vectors was used to assess helicity and vorticity. We quantified flow displacement (FD), systolic flow reversal ratio (sFRR) and rotational angle (RA) using 2D PC. Results For visual vortex flow presence near the inner curvature of the ascending aortic root on 4D flow CMR, sFRR demonstrated an area under the curve (AUC) of 0.955, p8% for sFRR had a sensitivity of 82% and specificity of 100% for visual vortex presence. In addition, the average late systolic FD, a marker of flow eccentricity, also demonstrated an AUC of 0.909, p<0.001 for visual vortex flow. Manual systolic rotational flow angle change (ΔsRA) demonstrated excellent association with semiautomated ΔsRA (r=0.99, 95% CI 0.9907 to 0.999, p<0.001). In reproducibility testing, average systolic FD (FDsavg) showed a minimal bias at 1.28% with a high intraclass correlation coefficient (ICC=0.92). Similarly, sFRR had a minimal bias of 1.14% with an ICC of 0.96. ΔsRA demonstrated an acceptable bias of 5.72°-and an ICC of 0.99. Conclusion 2D PC flow imaging can possibly quantify blood flow helicity (ΔRA) and vorticity (FRR). These imaging biomarkers of flow helicity and vorticity demonstrate high reproducibility for clinical adoption

    MRI texture analysis of subchondral bone at the tibial plateau

    Get PDF
    OBJECTIVES: To determine the feasibility of MRI texture analysis as a method of quantifying subchondral bone architecture in knee osteoarthritis (OA).   METHODS: Asymptomatic subjects aged 20-30 (group 1, n = 10), symptomatic patients aged 40-50 (group 2, n = 10) and patients scheduled for knee replacement aged 55-85 (group 3, n = 10) underwent high spatial resolution T1-weighted coronal 3T knee MRI. Regions of interest were created in the medial (MT) and lateral (LT) tibial subchondral bone from which 20 texture parameters were calculated. T2 mapping of the tibial cartilage was performed in groups 1 and 2. Mean parameter values were compared between groups using ANOVA. Linear discriminant analysis (LDA) was used to evaluate the ability of texture analysis to classify subjects correctly.   RESULTS: Significant differences in 18/20 and 12/20 subchondral bone texture parameters were demonstrated between groups at the MT and LT respectively. There was no significant difference in mean MT or LT cartilage T2 values between group 1 and group 2. LDA demonstrated subject classification accuracy of 97 % (95 % CI 91-100 %).   CONCLUSION: MRI texture analysis of tibial subchondral bone may allow detection of alteration in subchondral bone architecture in OA. This has potential applications in understanding OA pathogenesis and assessing response to treatment.   KEY POINTS: • Improved techniques to monitor OA disease progression and treatment response are desirable • Subchondral bone (SB) may play significant role in the development of OA • MRI texture analysis is a method of quantifying changes in SB architecture • Pilot study showed that this technique is feasible and reliable • Significant differences in SB texture were demonstrated between individuals with/without OA

    Physiology of the small bowel:a new approach using MRI and proposal for a new metric of function

    No full text
    The mechanics of small bowel motility are extremely complex. Routine clinical access to small bowel has been restricted to radiological enteric contrast studies which have not contributed significantly to the understanding of small bowel physiology. Small bowel mechanics are understood within a framework of individual visible or measurable elements such as peristaltic wave formation, intra-luminal pressure gradients and transit times. There are no global measures of small bowel function that can be readily obtained in vivo in humans. Magnetic resonance imaging (MRI) is playing an increasingly important role in radiological diagnosis of small bowel disease and dynamic MRI offers the possibility of capturing small bowel movement in three-dimensional cinematic datasets. The metrics that are used to describe small bowel mechanics, typically anatomical measures in isolated segments, are not suited to analysing these large dynamic datasets. The proposal in this paper is to leave behind all previously described anatomical metrics and to describe anew the mechanics of small bowel movement in mathematical terms derived from changes in pixel intensity within dynamic MRI datasets so that global small bowel activity might be summarised in a single novel metric