67 research outputs found

    Conditions for use and implementation of globally-aligned versus local baseplate coordinate systems when computing migration using radiostereometric analysis

    Get PDF
    Radiostereometric analysis can be used for computing movement of a tibial baseplate relative to the tibia (termed migration) to determine stability of fixation. Quantifying migration in six degrees of freedom requires establishing a coordinate system in which to express the movement. Establishing consistent migration directions among patients and baseplate designs remains challenging. Deviations in imaging alignment (tibia/baseplate alignment during image acquisition) and surgical alignment (baseplate alignment on tibia) will affect computed migrations when using the conventional globally-aligned baseplate coordinate system (BCS) (defined by calibration box). Computing migration using a local BCS (defined by baseplate) may be preferrable. This paper (1) summarizes the migration equations when using a globally-aligned versus local BCS, (2) proposes a method for defining a local BCS, and (3) demonstrates differences in the two BCSs for an example patient whose baseplate has rotational deviations due to imaging or surgical alignments. Differences in migration for the two BCSs ranged from about +/- 0.5 mm in translations and -0.4 deg to 0.7 deg in rotations. Differences were largest for deviations in internal-external rotation and smallest for deviations in varus-valgus rotation. An example demonstrated that the globally-aligned BCS resulted in migration being quantified as subsidence instead of liftoff, thereby changing fundamental interpretations. Because migrations computed using a local BCS are independent of imaging and surgical alignments and instead characterize migration using baseplate features, a local BCS enhances consistency in migration directions among patients and baseplate designs relative to the interface in which fixation may be compromised.Orthopaedics, Trauma Surgery and Rehabilitatio

    Comparative return of imports into the state of Pahang during the first quarters, 1917 and 1916.

    Get PDF
    Supplement to the F.M.S Government Gazette, July 6th, 1917. It also contains 'Comparative return of exports into the state of Pahang during the first quarters, 1917 and 1916'

    Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study

    Get PDF
    Background: Investigation of polyethylene liner movement in total hip arthroplasty requires bead-marking for radiographic visibility of the liner. However, occlusion of markers poses a challenge for marker registration in radiographs.Methods: The polyethylene of a dual mobility acetabular system was marked with twelve 1-mm tantalum markers (four groups of three markers) using a custom-made drill guide. Liner motion in a phantom and a patient was investigated with dynamic radiostereometry analysis (dRSA) at 1-year follow-up and static radiostereometry analysis (sRSA) postoperatively and at 1- and 2-year follow-up. A combined marker configuration (CMC) model was calculated from the registered positions of the liner markers and the femoral head in several images. Furthermore, the CMC model and the theoretic marker positions from computer-assisted models of the drill guide were combined in a hybrid model.Results: The CMC model included eleven markers in the phantom and nine markers in the patient, which was sufficient for dRSA. Liner movement in the phantom followed liner contact with the femoral neck, while liner movement in the patient was independent. The hybrid model was necessary to determine liner orientation in sRSA recordings, which clearly changed from postoperative to 1- and 2-year follow-up even though the patient was positioned similarly.Conclusion: Polyethylene liner motion in dual mobility hip prosthesis can be assessed with CMC models in dRSA recordings. In sRSA, the liner position between follow-ups is unpredictable and analysis requires inclusion of all markers in the model, accomplished with a hybrid marker model.Orthopaedics, Trauma Surgery and Rehabilitatio

    A randomized controlled trial comparing tibial migration of the ATTUNE cemented cruciate-retaining knee prosthesis with the PFC-sigma design

    Get PDF
    AimsThe primary objective of this study was to compare migration of the cemented ATTUNE fixed bearing cruciate retaining tibial component with the cemented Press-Fit Condylar (PFC)-sigma fixed bearing cruciate retaining tibial component. The secondary objectives included comparing clinical and radiological outcomes and Patient Reported Outcome Measures (PROMs).MethodsA single blinded randomized, non-inferiority study was conducted including 74 patients. Radiostereometry examinations were made after weight bearing, but before hospital discharge, and at three, six, 12, and 24 months postoperatively. PROMS were collected preoperatively and at three, six, 12, and 24 months postoperatively. Radiographs for measuring radiolucencies were collected at two weeks and two years postoperatively.ResultsThe overall migration (mean maximum total point motion (MPTM)) at two years was comparable: mean 1.13 mm (95% confidence interval (CI), 0.97 to 1.30) for the ATTUNE and 1.16 mm (95% CI, 0.99 to 1.35) for the PFC-sigma. At two years, the mean backward tilting was -0.43 degrees (95% CI, -0.65 to -0.21) for the ATTUNE and 0.08 degrees (95% CI -0.16 to 0.31), for the PFC-sigma. Overall migration between the first and second postoperative year was negligible for both components.The clinical outcomes and PROMs improved compared with preoperative scores and were not different between groups. Radiolucencies at the implant-cement interface were mainly seen below the medial baseplate: 17% in the ATTUNE and 3% in the PFC-sigma at two weeks, and at two years 42% and 9% respectively (p = 0.001).ConclusionIn the first two postoperative years the initial version of the ATTUNE tibial component was not inferior with respect to overall migration, although it showed relatively more backwards tilting and radiolucent lines at the implant-cement interface than the PFC-sigma. The version of the ATTUNE tibial component examined in this study has subsequently undergone modification by the manufacturer.Development and application of statistical models for medical scientific researc

    A randomized controlled trial comparing two-year postoperative femoral and tibial migration of a new and an established cementless rotating platform total knee arthroplasty

    Get PDF
    AimsThe primary aim of this study was to compare the migration of the femoral and tibial components of the cementless rotating platform Attune and Low Contact Stress (LCS) total knee arthroplasty (TKA) designs, two years postoperatively, using radiostereometric analysis (RSA) in order to assess the risk of the development of aseptic loosening. A secondary aim was to compare clinical and patient-reported outcome measures (PROMs) between the designs.MethodsA total of 61 TKAs were analyzed in this randomized clinical RSA trial. RSA examinations were performed one day and three, six, 12, and 24 months postoperatively. The maximal total point motion (MPTM), translations, and rotations of the components were analyzed. PROMs and clinical data were collected preoperatively and at six weeks and three, six, 12, and 24 months postoperatively. Linear mixed effect modelling was used for statistical analyses.ResultsThe mean MTPM two years postoperatively (95% confidence interval (CI)) of the Attune femoral component (0.92 mm (0.75 to 1.11)) differed significantly from that of the LCS TKA (1.72 mm (1.47 to 2.00), p < 0.001). The Attune femoral component subsided, tilted (anteroposteriorly), and rotated (internal-external) significantly less. The mean tibial MTPM two years postoperatively did not differ significantly, being 1.11 mm (0.94 to 1.30) and 1.17 mm (0.99 to 1.36, p = 0.447) for the Attune and LCS components, respectively. The rate of migration in the second postoperative year was negligible for the femoral and tibial components of both designs. The mean pain-at-rest (numerical rating scale (NRS)-rest) in the Attune group was significantly less compared with that in the LCS group during the entire follow-up period. At three months postoperatively, the Knee injury and Osteoarthritis Outcome Physical Function Shortform score, the Oxford Knee Score, and the NRS-activity scores were significantly better in the Attune group.ConclusionThe mean MTPM of the femoral components of the cementless rotating platform Attune was significantly less compared with that of the LCS design. This was reflected mainly in significantly less subsidence, posterior tilting, and internal rotation. The mean tibial MTPMs were not significantly different. During the second postoperative year, the components of both designs stabilized and low risks for the development of aseptic loosening are expected.Orthopaedics, Trauma Surgery and Rehabilitatio

    Five-year results of a randomised controlled trial comparing cemented and cementless Oxford unicompartmental knee replacement using radiostereometric analysis

    Get PDF
    Background: Cementless fixation is an alternative to cemented unicompartmental knee replacement (UKR). The aim of this study was to determine if cementless UKR fixation is as good as cemented by comparing the five-year migration measured radiostereometric analysis (RSA) in a randomised controlled trial.Methods: Thirty-nine patients were randomised to receive either a cemented or a cementless Oxford UKR and were studied at intervals up to five years to assess migration with RSA and radiolucencies with radiographs.Results: During the first year there was a small and significant amount of migration, predominantly in an anterior direction, of both the cemented (0.24 mm, SD 0.32, p = 0.01) and cementless (0.26 mm, SD 0.31, p = 0.00) femoral components. Thereafter there was no significant migration in any direction. At no stage was there any significant difference between the migrations of the cemented or cementless femoral components. During the first year, particularly the first three months, the cementless tibial components subsided 0.28 mm (SD 0.19, p = 0.00). This was significantly (p = 0.00) greater than the subsidence of the cemented tibial component (0.09, SD 0.19, p = 0.28). Between the second and fifth years there was no significant migration of either cemented or cementless tibial components.At five years radiolucent lines occurred significantly less with cementless (one partial) compared to cemented (six partial and one complete) tibial components.Conclusions: As, between two and five years, there was no significant migration of cemented or cementless components, and no significant difference between them, we conclude that cementless fixation is as reliable as cemented. It may be better as there are fewer radiolucent lines. (C) 2020 Elsevier B.V. All rights reserved.Orthopaedics, Trauma Surgery and Rehabilitatio

    Anatomical Modelling of the Musculoskeletal System from MRI

    Full text link
    Abstract. This paper presents a novel approach for multi-organ (mus-culoskeletal system) automatic registration and segmentation from clini-cal MRI datasets, based on discrete deformable models (simplex meshes). We reduce the computational complexity using multi-resolution forces, multi-resolution hierarchical collision handling and large simulation time steps (implicit integration scheme), allowing real-time user control and cost-efficient segmentation. Radial forces and topological constraints (at-tachments) are applied to regularize the segmentation process. Based on a medial axis constrained approximation, we efficiently characterize shapes and deformations. We validate our methods for the hip joint and the thigh (20 muscles, 4 bones) on 4 datasets: average error=1.5mm, computation time=15min.

    Clockwise Torque of Sliding Hip Screws: Is There a Right Side?

    Get PDF
    OBJECTIVES: This study evaluated whether patients with a left-sided femoral neck fracture (FNF) treated with a sliding hip screw (SHS) had a higher implant failure rate than patients treated for a right-sided FNF. This was performed to determine the clinical relevance of the clockwise rotational torque of the femoral neck lag screw in a SHS, in relation to the rotational stability of left and right-sided FNFs after fixation. METHODS: Data were derived from the FAITH trial and Dutch Hip Fracture Audit (DHFA). Patients with a FNF, aged ≥50, treated with a SHS, with at least 3-month follow-up data available, were included. Implant failure was analyzed in a multivariable logistic regression model adjusted for age, sex, fracture displacement, prefracture living setting and functional mobility, and American Society for Anesthesiologists Class. RESULTS: One thousand seven hundred fifty patients were included, of which 944 (53.9%) had a left-sided and 806 (46.1%) a right-sided FNF. Implant failure occurred in 60 cases (3.4%), of which 31 were left-sided and 29 right-sided. No association between fracture side and implant failure was found [odds ratio (OR) for left vs. right 0.89, 95% confidence interval (CI) 0.52-1.52]. Female sex (OR 3.02, CI: 1.62-6.10), using a mobility aid (OR 2.02, CI 1.01-3.96) and a displaced fracture (OR 2.51, CI: 1.44-4.42), were associated with implant failure. CONCLUSIONS: This study could not substantiate the hypothesis that the biomechanics of the clockwise screw rotation of the SHS contributes to an increased risk of implant failure in left-sided FNFs compared with right-sided fractures. LEVEL OF EVIDENCE: Therapeutic Level II.See Instructions for Authors for a complete description of levels of evidence