1,168 research outputs found

    An integrated DC-DC step-up charge pump and step-down converter in 130 nm technology

    Get PDF
    After the LHC luminosity upgrade the number of readout channels in the ATLAS Inner Detector will be increased by one order of magnitude and delivering the power to the front-end electronics as well as cooling will become a critical system issue. Therefore a new solution for powering the readout electronics has to be worked out. Two main approaches for the power distribution are under development, the serial powering of a chain of modules and the parallel powering with a DCDC conversion stage on the detector. In both cases switchedcapacitor converters in the CMOS front-end chips will be used. In the paper we present the design study of a step-up charge pump and a step-down converter. In optimized designs power efficiency of 85 % for the step-up converter and 92 % for the step-down converter has been achieved

    High-rate GPS positioning for tracing anthropogenic seismic activity. The 29 January 2019 mining tremor in Legnica- Głogów Copper District, Poland

    Get PDF
    High-rate GNSS observations are usually studied in relation to earthquake analysis and structural monitoring. Most of the previous research on short-term dynamic deformations has been limited to natural earthquakes with magnitudes exceeding 5 and amplitudes equal to several dozen centimetres. High-frequency position monitoring via GNSS stations is particularly important in mining areas due to the need to monitor mining damages. On 29 January 2019 (12:53:44 UTC), an M3.7 event occurred in the area of Legnica-Głogów Copper District. This study presents GPS-derived displacement analysis in relation to seismological data. Station position time series were determined by double differencing and Precise Point Positioning. The peak ground displacement was 2–14 mm. The correlation coefficients between GPS and seismological displacement time series reached 0.92. A statistical evaluation of GPS displacement time series was carried out to detect an event using only GPS observations

    Population parameter estimates for performance and reproductive traits in Polish Large White nucleus herds

    Get PDF
    Performance test records from on-farm tests of young Polish Large White boars and reproductive records of Polish Large White sows from 94 nucleus farms during 1978 to 1987 were used to estimate population parameters for the measured traits. The number of boar performance records after editing was 114,347 from 3,932 sues, 21,543 dams, 44,493 litters and 1,075 herd-year-seasons. Reproductive performance records of sows involved 41,080 litters from 2,348 sires, 18,683 dams and 1,520 herd-year-seasons. Both data sets were analyzed by using restricted maximum-likelihood programs. The model used for the pedormance records included fixed herd-year-seasons, random sires, dams and error effects, and covariances for the year of birth of sire and year of birth of dam. The model used for the reproduction data set was the same as the performance data with parity as an additional fiied effect. Estimated heritabilities were .27, .29, .26, .07, .06, .06 for average daily gain standardized to 180 d (ADG), backfat thickness standardized to 110 kg BW (BF), days to 110 kg (DAYS), litter size at birth born alive (NBA), litter size at 21 d (N21) and litter weight at 21 d (W21). respectively. Estimated common environmental effects for the same traits were .09, .lo, .09, .06, .07 and .OS, respectively. Genetic correlations were .68 (NBA and W21) and .80 (N21 and W21). The respective phenotypic correlations were .23, -.99, -.20, .88, .75, .86. These population parameters for Polish Large White pigs are similar to those for breeds in other countries

    Performance of the ABCN-25 readout chip for the ATLAS Inner Detector Upgrade

    Get PDF
    We present the test results of the ABCN-25 front end chip implemented in CMOS 0.25 μm technology and optimised for the short, 2.5 cm, silicon strips intended to be used in the upgrade of the ATLAS Inner Detector. We have obtained the full functionality of the readout part, the expected performance of the analogue front-end and the operation of the power control circuits. The performance is evaluated in view of the minimization of the power consumption, as the upgrade detector may contain up to 70 million of channels. System tests with different power distribution schemes proposed for the future tracker detectors are possible with this chip. The ABCN-25 ASIC is now serving as the prototype readout chip in the developments of the modules and staves for the upgrade of the ATLAS Inner Detector

    Epidemiology and clinical features of gastroenteritis in hospitalised children: prospective survey during a 2-year period in a Parisian hospital, France

    Get PDF
    International audienceRotavirus is recognised as the most important agent of severe acute gastroenteritis (AGE) in young children. In a 2-year prospective survey, we investigated the epidemiology and clinical features of the viral and bacterial pathogens in children hospitalised for AGE. The study was performed in a Parisian teaching hospital from November 2001 to May 2004. Clinical data were prospectively collected to assess the gastroenteritis severity (20-point Vesikari severity score, the need for intravenous rehydration, duration of hospitalisation). Stools were systematically tested for group A rotavirus, norovirus, astrovirus and adenovirus 40/41, sapovirus and Aichi virus and enteropathogenic bacteria. A total of 457 children (mean age 15.9 months) were enrolled. Viruses were detected in 305 cases (66.7%) and bacteria in 31 cases (6.8%). Rotaviruses were the most frequent pathogen (48.8%), followed by noroviruses (8.3%) and adenoviruses, astroviruses, Aichi viruses and sapoviruses in 3.5%, 1.5%, 0.9% and 0.4%, respectively. Cases of rotavirus gastroenteritis were significantly more severe than those of norovirus with respect to the Vesikari score, duration of hospitalisation and the need for intravenous rehydration. Rotaviruses were the most frequent and most severe cause in children hospitalised for AGE, and noroviruses also account for a large number of cases in this population

    Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

    Full text link
    Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals and an example of an application of the method for a single module with a 30 cm long plastic strip, read out on both ends by Hamamatsu R4998 photomultipliers. The sampling scheme to generate a vector with samples of a PET event waveform with respect to four user-defined amplitudes is introduced. The experimental setup provides irradiation of a chosen position in the plastic scintillator strip with an annihilation gamma quanta of energy 511~keV. The statistical test for a multivariate normal (MVN) distribution of measured vectors at a given position is developed, and it is shown that signals sampled at four thresholds in a voltage domain are approximately normally distributed variables. With the presented method of a vector analysis made out of waveform samples acquired with four thresholds, we obtain a spatial resolution of about 1 cm and a timing resolution of about 80 p

    Compressive Sensing of Signals Generated in Plastic Scintillators in a Novel J-PET Instrument

    Full text link
    The J-PET scanner, which allows for single bed imaging of the whole human body, is currently under development at the Jagiellonian University. The dis- cussed detector offers improvement of the Time of Flight (TOF) resolution due to the use of fast plastic scintillators and dedicated electronics allowing for sam- pling in the voltage domain of signals with durations of few nanoseconds. In this paper we show that recovery of the whole signal, based on only a few samples, is possible. In order to do that, we incorporate the training signals into the Tikhonov regularization framework and we perform the Principal Component Analysis decomposition, which is well known for its compaction properties. The method yields a simple closed form analytical solution that does not require iter- ative processing. Moreover, from the Bayes theory the properties of regularized solution, especially its covariance matrix, may be easily derived. This is the key to introduce and prove the formula for calculations of the signal recovery error. In this paper we show that an average recovery error is approximately inversely proportional to the number of acquired samples

    Application of the Compress Sensing Theory for Improvement of the TOF Resolution in a Novel J-PET Instrument

    Get PDF
    Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight information is used to improve the image reconstruction process. In Time of Flight PET (TOF-PET), fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten significantly a range along the line-of-response (LOR) where the annihilation occurred. In the new concept, called J-PET scanner, gamma rays are detected in plastic scintillators. In a single strip of J-PET system, time values are obtained by probing signals in the amplitude domain. Owing to Compress Sensing theory, information about the shape and amplitude of the signals is recovered. In this paper we demonstrate that based on the acquired signals parameters, a better signal normalization may be provided in order to improve the TOF resolution. The procedure was tested using large sample of data registered by a dedicated detection setup enabling sampling of signals with 50 ps intervals. Experimental setup provided irradiation of a chosen position in the plastic scintillator strip with annihilation gamma quanta

    The ATLAS SCT grounding and shielding concept and implementation

    Get PDF
    This paper presents a complete description of Virgo, the French-Italian gravitational wave detector. The detector, built at Cascina, near Pisa (Italy), is a very large Michelson interferometer, with 3 km-long arms. In this paper, following a presentation of the physics requirements, leading to the specifications for the construction of the detector, a detailed description of all its different elements is given. These include civil engineering infrastructures, a huge ultra-high vacuum (UHV) chamber (about 6000 cubic metres), all of the optical components, including high quality mirrors and their seismic isolating suspensions, all of the electronics required to control the interferometer and for signal detection. The expected performances of these different elements are given, leading to an overall sensitivity curve as a function of the incoming gravitational wave frequency. This description represents the detector as built and used in the first data-taking runs. Improvements in different parts have been and continue to be performed, leading to better sensitivities. These will be detailed in a forthcoming paper
    corecore