195 research outputs found

    Low-cost reusable instrumentation for laparoendoscopic single-site nephrectomy: assessment in a porcine model

    Get PDF
    PURPOSE: To test different sets of prebent instruments and a new reusable access device for laparoendoscopic single-site (LESS) surgery. MATERIALS AND METHODS: Three surgeons with previous experience in LESS performed 12 nephrectomies in six pigs. In all procedures, a multichannel access device (X-CONE) and a 5-mm extra-long telescope were used. Four sets of prebent instruments with different profiles (S-portal) were tested: Standard (one straight scissors and one curved grasper), Cuschieri, Carus, and Leroy set (each of them consisting of two curved instruments with different configurations). Assessment was performed based on both objective (procedure time; time to manage the pedicle; time to free kidney) and subjective parameters (entry/exit of instruments; triangulation; dissection up/down; dissection lateral; retraction; interdependence). The subjective assessment tool used was a Likert type scale (1 = easy to 5 = prohibitive). The access device was assessed by using objective (time to complete insertion of device after skin incision) and subjective (significant air leakage, movement constraint) parameters. RESULTS: Time to insertion of the X-CONE was <1 minute in all the cases. Surgeons reported significant insufflant leakage in 58% of cases. The procedure was completed in 10/12 (83%) cases. Mean operative time was 8.3 ± 4.2 minutes, being lower for the Carus group (4.5 min) and higher for the standard group (13 min). Among the different sets, the standard one obtained the best mean scores for all subjective parameters. CONCLUSIONS: X-CONE allows easy abdominal access, and its reusable properties represent cost savings for LESS compared with disposable devices. Prebent instruments might also represent attractive low-cost tools for LESS

    Low-cost reusable instrumentation for laparoendoscopic single-site nephrectomy: assessment in a porcine model

    Get PDF
    PURPOSE: To test different sets of prebent instruments and a new reusable access device for laparoendoscopic single-site (LESS) surgery. MATERIALS AND METHODS: Three surgeons with previous experience in LESS performed 12 nephrectomies in six pigs. In all procedures, a multichannel access device (X-CONE) and a 5-mm extra-long telescope were used. Four sets of prebent instruments with different profiles (S-portal) were tested: Standard (one straight scissors and one curved grasper), Cuschieri, Carus, and Leroy set (each of them consisting of two curved instruments with different configurations). Assessment was performed based on both objective (procedure time; time to manage the pedicle; time to free kidney) and subjective parameters (entry/exit of instruments; triangulation; dissection up/down; dissection lateral; retraction; interdependence). The subjective assessment tool used was a Likert type scale (1 = easy to 5 = prohibitive). The access device was assessed by using objective (time to complete insertion of device after skin incision) and subjective (significant air leakage, movement constraint) parameters. RESULTS: Time to insertion of the X-CONE was <1 minute in all the cases. Surgeons reported significant insufflant leakage in 58% of cases. The procedure was completed in 10/12 (83%) cases. Mean operative time was 8.3 ± 4.2 minutes, being lower for the Carus group (4.5 min) and higher for the standard group (13 min). Among the different sets, the standard one obtained the best mean scores for all subjective parameters. CONCLUSIONS: X-CONE allows easy abdominal access, and its reusable properties represent cost savings for LESS compared with disposable devices. Prebent instruments might also represent attractive low-cost tools for LESS

    Laparoendoscopic single-site and natural orifice transluminal endoscopic surgery in urology: a critical analysis of the literature

    Get PDF
    CONTEXT: Natural orifice transluminal endoscopic surgery (NOTES) and laparoendoscopic single-site surgery (LESS) have been developed to benefit patients by enabling surgeons to perform scarless surgery. OBJECTIVE: To summarize and critically analyze the available evidence on the current status and future perspectives of LESS and NOTES in urology. EVIDENCE ACQUISITION: A comprehensive electronic literature search was conducted in June 2010 using the Medline database to identify all publications relating to NOTES and LESS in urology. EVIDENCE SYNTHESIS: In urology, NOTES has been completed experimentally via transgastric, transvaginal, transcolonic, and transvesical routes. Initial clinical experience has shown that NOTES urologic surgery using currently available instruments is indeed possible. Nevertheless, because of the immaturity of the instrumentation, early cases have demanded high technical virtuosity. LESS can safely and effectively be performed in a variety of urologic settings. As clinical experience increases, expanding indications are expected to be documented and the efficacy of the procedure to improve. So far, the quality of evidence of all available studies remains low, mostly being small case series or case-control studies from selected centers. Thus, the only objective benefit of LESS remains the improved cosmetic outcome. Prospective, randomized studies are largely awaited to determine which LESS procedures will be established and which are unlikely to stand the test of time. Technology advances hold promise to minimize the challenging technical nature of scarless surgery. In this respect, robotics is likely to drive a major paradigm shift in the development of LESS and NOTES. CONCLUSIONS: NOTES is still an investigational approach in urology. LESS has proven to be immediately applicable in the clinical field, being safe and feasible in the hands of experienced laparoscopic surgeons. Development of instrumentation and application of robotic technology are expected to define the actual role of these techniques in minimally invasive urologic surgery

    Transumbilical laparo-endoscopic single site surgery for adrenal cortical adenoma inducing primary aldosteronism: initial experience

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We have started using laparo-endoscopic single-site surgery (LESS) in urologic surgery, although its use has not gained momentum due to its level of difficulty. We here report our initial experience with transumbilical LESS for adrenal cortical adenoma by using a single port with a multichannel cannula (SILS port) and bent laparoscopic instrumentation.</p> <p>Findings</p> <p>A multichannel port (SILS port), bent laparoscopic instrument (Roticulator Endo Mini-Shears) and Opti4 laparoscopic electrodes were used in all cases. The intraperitoneal space was approached through the umbilicus. The SILS port was placed through a 2 cm incision at the inner edge of the umbilicus. A 5 mm flexible laparoscope was introduced to keep the laparoscope outside, and surgical specimens were extracted using an Endocatch bag. In addition, as a case control study, we compared perioperative data of LESS adrenalectomy (LESS-A) with that of conventional laparoscopic adrenalectomy (LA). We performed transumbilical LESS-A for adrenal cortical adenoma in 12 cases, beginning in December, 2009. All procedures were successfully completed, with only one incision through the umbilicus, and without conversion to a standard laparoscopic approach. Mean operative time for LESS-A was 121.2 ± 7.8 min, which was slightly longer than LA (110.2 ± 7.3 min). For right adrenal tumors, we used a miniport (2 mm port) in addition to a SILS port, and were able to successfully perform adrenalectomy "with no visible scaring". Tumor laterality and patient BMI did not affect surgical morbidity in these procedures. Moreover, there was no significant difference between LESS-A and LA in blood loss, analgesic requirement, hospital stay, and scar satisfaction.</p> <p>Conclusions</p> <p>The transumbilical approach in LESS for adrenalectomy is safe and feasible and also improves cosmetic outcome compared with standard laparoscopic procedures. Improvements in surgical devices may aid the further development of this approach.</p

    Initial experience of transumbilical laparoendoscopic single-site surgery of partial adrenalectomy in patient with aldosterone-producing adenoma

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Laparoscopic single-site surgery has recently emerged in the field of urology and this minimally-invasive surgery has resulted in a further reduction in morbidity compared with traditional laparoscopy. We present our initial experience with laparoendoscopic single-site surgery of partial adrenalectomy (LESS-PA) to treat aldosterone-producing adenomas.</p> <p>Case presentation</p> <p>A 60-year-old woman was diagnosed with aldosterone-producing macroadenomas in the left adrenal and aldosterone-producing microadenomas in the right adrenal. A two-step operation was planned. The first step involved transumbilical LESS-PA for the left adrenal tumors. A multichannel port was inserted through the center of the umbilicus and the left adrenal gland was approached using bent instruments according to standard traditional laparoscopic procedures. The tumors were resected using an ultrasonic scalpel, and the resected site was coagulated using a vessel sealing instrument and then sealed with fibrin glue. Operative time was 123 minutes and blood loss was minimal. The patient was discharged from hospital within 72 hours. Her right adrenal microadenomas will be treated in the next several months.</p> <p>Conclusions</p> <p>Although our experience is limited, LESS-PA appears to be safe and feasible for treating aldosterone-producing adenomas. More cases and comparisons with the multiport technique are needed before drawing any definite conclusions concerning the technique.</p
    • …
    corecore