10 research outputs found

    A simple iterative independent component analysis algorithm for vibration source signal identification of complex structures

    Get PDF
    ABSTRACT:Independent Component Analysis (ICA), one of the blind source separation methods, can be applied for extracting unknown source signals only from received signals. This is accomplished by finding statistical independence of signal mixtures and has been successfully applied to myriad fields such as medical science, image processing, and numerous others. Nevertheless, there are inherent problems that have been reported when using this technique: insta- bility and invalid ordering of separated signals, particularly when using a conventional ICA technique in vibratory source signal identification of complex structures. In this study, a simple iterative algorithm of the conventional ICA has been proposed to mitigate these problems. The proposed method to extract more stable source signals having valid order includes an iterative and reordering process of extracted mixing matrix to reconstruct finally converged source signals, referring to the magnitudes of correlation coefficients between the intermediately separated signals and the signals measured on or nearby sources. In order to review the problems of the conventional ICA technique and to vali- date the proposed method, numerical analyses have been carried out for a virtual response model and a 30m class submarine model. Moreover, in order to investigate applicability of the proposed method to real problem of complex structure, an experiment has been carried out for a scaled submarine mockup. The results show that the proposed method could resolve the inherent problems of a conventional ICA technique

    Performance of the Belle II Silicon Vertex Detector

    No full text
    The Belle II experiment at the SuperKEKB collider of KEK (Japan) will accumulate 50 ab−1 of e+e− collision data at an unprecedented instantaneous luminosity of 8 ×1035 cm−2s−1, about 40 times larger than its predecessor. The Belle II vertex detector plays a crucial role in the rich Belle II physics program, especially for time-dependent measurements. It consists of two layers of DEPFET-based pixels and four layers of double sided silicon strips detectors(SVD). The vertex detector has been recently completed and installed in Belle II for the physics run started in spring 2019. We report here results on the commissioning of the SVD and its performance measured with the first collision data set

    Data quality monitors of vertex detectors at the start of the Belle II experiment

    No full text
    The Belle II experiment features a substantial upgrade of the Belle detector and will operate at the SuperKEKB energy-asymmetric e+e− collider at KEK in Tsukuba, Japan. The accelerator completed its first phase of commissioning in 2016, and the Belle II detector saw its first electron-positron collisions in April 2018. Belle II features a newly designed silicon vertex detector based on double-sided strip layers and DEPFET pixel layers. A subset of the vertex detector was operated in 2018 to determine background conditions (Phase 2 operation). The collaboration completed full detector installation in January 2019, and the experiment started full data taking. This paper will report on the final arrangement of the silicon vertex detector part of Belle II with a focus on online monitoring of detector conditions and data quality, on the design and use of diagnostic and reference plots, and on integration with the software framework of Belle II. Data quality monitoring plots will be discussed with a focus on simulation and acquired cosmic and collision data

    Alignment for the first precision measurements at Belle II

    No full text
    International audienceOn March 25th 2019, the Belle II detector recorded the first collisions delivered by the SuperKEKB accelerator. This marked the beginning of the physics run with vertex detector.The vertex detector was aligned initially with cosmic ray tracks without magnetic field simultaneously with the drift chamber. The alignment method is based on Millepede II and the General Broken Lines track model and includes also the muon system or primary vertex position alignment. To control weak modes, we employ sensitive validation tools and various track samples can be used as alignment input, from straight cosmic tracks to mass-constrained decays.With increasing luminosity and experience, the alignment is approaching the target performance, crucial for the first physics analyses in the era of Super-BFactories. We will present the software framework for the detector calibration and alignment, the results from the first physics run and the prospects in view of the experience with the first data

    Alignment for the first precision measurements at Belle II

    Get PDF
    On March 25th 2019, the Belle II detector recorded the first collisions delivered by the SuperKEKB accelerator. This marked the beginning of the physics run with vertex detector. The vertex detector was aligned initially with cosmic ray tracks without magnetic field simultaneously with the drift chamber. The alignment method is based on Millepede II and the General Broken Lines track model and includes also the muon system or primary vertex position alignment. To control weak modes, we employ sensitive validation tools and various track samples can be used as alignment input, from straight cosmic tracks to mass-constrained decays. With increasing luminosity and experience, the alignment is approaching the target performance, crucial for the first physics analyses in the era of Super-BFactories. We will present the software framework for the detector calibration and alignment, the results from the first physics run and the prospects in view of the experience with the first data

    Data quality monitors of vertex detectors at the start of the Belle II experiment

    Get PDF
    The Belle II experiment features a substantial upgrade of the Belle detector and will operate at the SuperKEKB energy-asymmetric e+e− collider at KEK in Tsukuba, Japan. The accelerator completed its first phase of commissioning in 2016, and the Belle II detector saw its first electron-positron collisions in April 2018. Belle II features a newly designed silicon vertex detector based on double-sided strip layers and DEPFET pixel layers. A subset of the vertex detector was operated in 2018 to determine background conditions (Phase 2 operation). The collaboration completed full detector installation in January 2019, and the experiment started full data taking. This paper will report on the final arrangement of the silicon vertex detector part of Belle II with a focus on online monitoring of detector conditions and data quality, on the design and use of diagnostic and reference plots, and on integration with the software framework of Belle II. Data quality monitoring plots will be discussed with a focus on simulation and acquired cosmic and collision data

    Measurement of the Ωc0\Omega_c^0 lifetime at Belle II

    No full text
    We report on a measurement of the Ωc0\Omega_c^0 lifetime using Ωc0Ωπ+\Omega_c^0 \to \Omega^-\pi^+ decays reconstructed in e+eccˉe^+e^-\to c\bar{c} data collected by the Belle II experiment and corresponding to 207 fb1207~{\rm fb^{-1}} of integrated luminosity. The result, τ(Ωc0)=243±48(stat)±11(syst) fs\rm\tau(\Omega_c^0)=243\pm48( stat)\pm11(syst)~fs, agrees with recent measurements indicating that the Ωc0\Omega_c^0 is not the shortest-lived weakly decaying charmed baryon

    Measurement of the Ωc0\Omega_c^0 lifetime at Belle II

    No full text
    We report on a measurement of the Ωc0\Omega_c^0 lifetime using Ωc0Ωπ+\Omega_c^0 \to \Omega^-\pi^+ decays reconstructed in e+eccˉe^+e^-\to c\bar{c} data collected by the Belle II experiment and corresponding to 207 fb1207~{\rm fb^{-1}} of integrated luminosity. The result, τ(Ωc0)=243±48(stat)±11(syst) fs\rm\tau(\Omega_c^0)=243\pm48( stat)\pm11(syst)~fs, agrees with recent measurements indicating that the Ωc0\Omega_c^0 is not the shortest-lived weakly decaying charmed baryon

    Measurement of the Ωc0\Omega_c^0 lifetime at Belle II

    No full text
    We report on a measurement of the Ωc0\Omega_c^0 lifetime using Ωc0Ωπ+\Omega_c^0 \to \Omega^-\pi^+ decays reconstructed in e+eccˉe^+e^-\to c\bar{c} data collected by the Belle II experiment and corresponding to 207 fb1207~{\rm fb^{-1}} of integrated luminosity. The result, τ(Ωc0)=243±48(stat)±11(syst) fs\rm\tau(\Omega_c^0)=243\pm48( stat)\pm11(syst)~fs, agrees with recent measurements indicating that the Ωc0\Omega_c^0 is not the shortest-lived weakly decaying charmed baryon
    corecore