514 research outputs found

    Optimisation of pipeline route in the presence of obstacles based on a least cost path algorithm and laplacian smoothing

    Get PDF
    Subsea pipeline route design is a crucial task for the offshore oil and gas industry, and the route selected can significantly affect the success or failure of an offshore project. Thus, it is essential to design pipeline routes to be eco-friendly, economical and safe. Obstacle avoidance is one of the main problems that affect pipeline route selection. In this study, we propose a technique for designing an automatic obstacle avoidance. The Laplacian smoothing algorithm was used to make automatically generated pipeline routes fairer. The algorithms were fast and the method was shown to be effective and easy to use in a simple set of case studies

    Application of morphing technique with mesh-merging in rapid hull form generation

    Get PDF
    ABSTRACTMorphing is a geometric interpolation technique that is often used by the animation industry to transform one form into another seemingly seamlessly. It does this by producing a large number of ‘intermediate’ forms between the two ‘extreme’ or ‘parent’ forms. It has already been shown that morphing technique can be a powerful tool for form design and as such can be a useful addition to the armoury of product designers. Morphing procedure itself is simple and consists of straightforward linear interpolation. However, establishing the correspondence between vertices of the parent models is one of the most difficult and important tasks during a morphing process. This paper discusses the mesh-merging method employed for this process as against the already established mesh-regularising method. It has been found that the merging method minimises the need for manual manipulation, allowing automation to a large extent

    Role of Balloon Guide Catheter in Modern Endovascular Thrombectomy

    Get PDF
    Proximal flow control achieved with a balloon guide catheter (BGC) during endovascular treatment of acute ischemic stroke is reviewed in this article. In clinical practice, BGCs offer a multi-faceted approach for clot retrieval by creating proximal flow arrest, reducing embolic burden, and shortening procedure time. Evaluation of frontline thrombectomy procedures with BGCs revealed advantages of combined use over the conventional guide catheter (CGC), notably in the significant reduction of distal emboli to both the affected and previously unaffected territories. Recently, new measures of early and complete reperfusion at first thrombectomy pass have been identified as independent predictors of improved outcomes, which were consistently demonstrated with use of BGC as a safe and effective option to minimize number of passes during intervention. Prior randomized controlled trials reported the positive correlation between BGC-treated patients and a lower risk of mortality as well as shortened procedure time. While BGC use is more common in stent retriever-mediated mechanical thrombectomy, preliminary data has shown the potential benefit of device application during contact aspiration thrombectomy to achieve successful recanalization. However, the question of which major endovascular strategy reigns superior as a frontline remains to be answered. Along with clinical case assessments, BGC performance during in-vitro simulation was analyzed to further understand mechanisms for optimization of thrombectomy technique

    Mesenchymal stem cell-derived magnetic extracellular nanovesicles for targeting and treatment of ischemic stroke

    Get PDF
    Exosomes and extracellular nanovesicles (NV) derived from mesenchymal stem cells (MSC) may be used for the treatment of ischemic stroke owing to their multifaceted therapeutic benefits that include the induction of angiogenesis, anti-apoptosis, and anti-inflammation. However, the most serious drawback of using exosomes and NV for ischemic stroke is the poor targeting on the ischemic lesion of brain after systemic administration, thereby yielding a poor therapeutic outcome. In this study, we show that magnetic NV (MNV) derived from iron oxide nanoparticles (IONP)-harboring MSC can drastically improve the ischemic-lesion targeting and the therapeutic outcome. Because IONP stimulated expressions of therapeutic growth factors in the MSC, MNV contained greater amounts of those therapeutic molecules compared to NV derived from naive MSC. Following the systemic injection of MNV into transient middle-cerebral-artery-occlusion (MCAO)-induced rats, the magnetic navigation increased the MNV localization to the ischemic lesion by 5.1 times. The MNV injection and subsequent magnetic navigation promoted the anti-inflammatory response, angiogenesis, and anti-apoptosis in the ischemic brain lesion, thereby yielding a considerably decreased infarction volume and improved motor function. Overall, the proposed MNV approach may overcome the major drawback of the conventional MSC-exosome therapy or NV therapy for the treatment of ischemic stroke.

    Effect of rhBMP-2 applied with a 3D-printed titanium implant on new bone formation in rabbit calvarium

    Get PDF
    Objective: This study sought to compare the biocompatibility of a three-dimensional (3D)-printed titanium implant with a conventional machined titanium product, as well as the effect of such implant applied with recombinant human Bone Morphogenetic Protein Type 2 (rhBMP-2) for guided bone regeneration. Methodology: Disk-shaped titanium specimens fabricated either by the conventional machining technique or by the 3D-printing technique were compared by MC3T3-E1 cells cytotoxicity assay. New bone formation was evaluated using a rapid prototype titanium cap applied to the calvaria of 10 rabbits, which were divided into two groups: one including an atelopeptide collagen plug on one side of the cap (group I) and the other including a plug with rhBMP-2 on the other side (group II). At six and 12 weeks after euthanasia, rabbits calvaria underwent morphometric analysis through radiological and histological examination. Results: Through the cytotoxicity assay, we identified a significantly higher number of MC3T3-E1 cells in the 3D-printed specimen when compared to the machined specimen after 48 hours of culture. Moreover, morphometric analysis indicated significantly greater bone formation at week 12 on the side where rhBMP-2 was applied when evaluating the upper portion immediately below the ca p. Conclusion: The results suggest that 3D-printed titanium implant applied with rhBMP-2 enables new bone formation

    Monoclinic and Correlated Metal Phase in VO_2 as Evidence of the Mott Transition: Coherent Phonon Analysis

    Full text link
    In femtosecond pump-probe measurements, the appearance of coherent phonon oscillations at 4.5 THz and 6.0 THz indicating the rutile metal phase of VO_2 does not occur simultaneously with the first-order metal-insulator transition (MIT) near 68^oC. The monoclinic and correlated metal(MCM) phase between the MIT and the structural phase transition (SPT) is generated by a photo-assisted hole excitation which is evidence of the Mott transition. The SPT between the MCM phase and the rutile metal phase occurs due to subsequent Joule heating. The MCM phase can be regarded as an intermediate non-equilibrium state.Comment: 4 pages, 2 figure

    Electro-Mechanical Safety Testing of Portable ECG Devices for Home Healthcare Usage

    Get PDF
    OBJECTIVES: This paper suggests the experimental guidelines to evaluate the electro-mechanical safety of belt type equipment. The electro-mechanical safety was determined by using the International Electrotechnical Commission guidelines, which are widely used as important factors for assessing the electro-mechanical safety of belt type equipment. However, the local guidelines on wearable healthcare sensors are currently not well-established. Therefore, safety guidelines suited for the actual circumstances in Korea are required, and this paper attempts to try a new experimental safety test procedure of the wearable healthcare sensor. METHODS: This belt type device measures the electrocardiogram (ECG) and heart rates by attaching to the chest. Examination lists were selected by analyzing the common standards ofelectro-mechanical safety (IEC 60601-1) and environment tests (IEC 60068-1, IEC 60068-2) of home-healthcare equipment. RESULTS: The essential electrical safety, which was required for the RS300G3 as a medical device, was evaluated, and most of the examination lists were selected by considering the circumstances of the users. The device passed all the selected examinable lists that are applicable to the Korean environment. CONCLUSIONS: This study has limitations to estimate and to conduct electro-mechanical safety experiments because our study focused on the belt type of heart-rates equipment. We are not taking into account the overall electro-mechanical home-healthcare measurements. According to industrial and technological development, there are infinite possibilities for the advancement of home-healthcare equipment, so more examination lists for safety are being added in addition to what we have doneope
    corecore