70 research outputs found
Recommended from our members
A field-deployable gamma-ray spectrometer utilizing high pressure xenon
Most nuclear materials in the nuclear energy, safeguards, arms control, and nonproliferation regimes emit gamma rays with a unique signature. Currently, two categories of spectrometers are available to evaluate these materials: (1) Semiconductors, with excellent energy resolution, which operate at cryogenic temperatures. (2) Scintillation detectors, which function at ambient temperature, but with poor energy resolution. A detector which functions for extended periods in a range of environments, with an energy resolution superior to that of a scintillation spectrometer, would have evident utility. Recently, in the research community, such a device has evolved, an ionization chamber utilizing xenon gas at very high pressure (60 atm). Its energy resolution, typically, is 20 keV for the 661 keV gamma ray of {sup 137}Cs. With high xenon density and its high atomic number (Z=54), and superior energy resolution, its sensitivity is comparable to that of a scintillator
Recommended from our members
A portable gamma-ray spectrometer using compressed xenon
An ionization chamber using compressed xenon has been designed and built for gamma-ray spectrometry. The device is based on signal measurement from a parallel plate detector, with the gas enclosure constructed specifically for packaging into a portable instrument; thus, appropriate engineering practices comprises two small containers that can be setup for operation in just a few minutes. Its sensitivity is 100 keV to over 1 MeV, with a resolution at 662 keV of 2.5% FWHM for uniform irradiation, and 2% FWHM for collimated irradiation, comparable to the best ever with compressed xenon. It also exhibits greater specificity that most scintillators, such as NaI. The device is insensitive to neutron damage and has a low power requirement
A Compact Beam Stop for a Rare Kaon Decay Experiment
We describe the development and testing of a novel beam stop for use in a
rare kaon decay experiment at the Brookhaven AGS. The beam stop is located
inside a dipole spectrometer magnet in close proximity to straw drift chambers
and intercepts a high-intensity neutral hadron beam. The design process,
involving both Monte Carlo simulations and beam tests of alternative beam-stop
shielding arrangements, had the goal of minimizing the leakage of particles
from the beam stop and the resulting hit rates in detectors, while preserving
maximum acceptance for events of interest. The beam tests consisted of
measurements of rates in drift chambers, scintilation counter hodoscopes, a gas
threshold Cherenkov counter, and a lead glass array. Measurements were also
made with a set of specialized detectors which were sensitive to low-energy
neutrons, photons, and charged particles. Comparisons are made between these
measurements and a detailed Monte Carlo simulation.Comment: 39 pages, 14 figures, submitted to Nuclear Instruments and Method
A straw drift chamber spectrometer for studies of rare kaon decays
We describe the design, construction, readout, tests, and performance of
planar drift chambers, based on 5 mm diameter copperized Mylar and Kapton
straws, used in an experimental search for rare kaon decays. The experiment
took place in the high-intensity neutral beam at the Alternating Gradient
Synchrotron of Brookhaven National Laboratory, using a neutral beam stop, two
analyzing dipoles, and redundant particle identification to remove backgrounds
Phylogeny and distribution of nitrate-storing Beggiatoa spp. in coastal marine sediments
Ion-beam excitation of liquid argon
The scintillation light of liquid argon has been recorded wavelength and time resolved with very good statistics in a wavelength interval ranging from 118 nm through 970 nm. Three different ion beams, protons, sulfur ions and gold ions, were used to excite liquid argon. Only minor differences were observed in the wavelength-spectra obtained with the different incident particles. Light emission in the wavelength range of the third excimer continuum was found to be strongly suppressed in the liquid phase. In time-resolved measurements, the time structure of the scintillation light can be directly attributed to wavelength in our studies, as no wavelength shifter has been used. These measurements confirm that the singlet-to-triplet intensity ratio in the second excimer continuum range is a useful parameter for particle discrimination, which can also be employed in wavelength-integrated measurements as long as the sensitivity of the detector system does not rise steeply for wavelengths longer than 190 nm. Using our values for the singlet-to-triplet ratio down to low energies deposited a discrimination threshold between incident protons and sulfur ions as low as ∼2.5 keV seems possible, which represents the principle limit for the discrimination of these two species in liquid argon
A giant planet candidate transiting a white dwarf
Astronomers have discovered thousands of planets outside the Solar System1, most of which orbit stars that will eventually evolve into red giants and then into white dwarfs. During the red giant phase, any close-orbiting planets will be engulfed by the star2, but more distant planets can survive this phase and remain in orbit around the white dwarf3,4. Some white dwarfs show evidence for rocky material floating in their atmospheres5, in warm debris disks6–9 or orbiting very closely10–12, which has been interpreted as the debris of rocky planets that were scattered inwards and tidally disrupted13. Recently, the discovery of a gaseous debris disk with a composition similar to that of ice giant planets14 demonstrated that massive planets might also find their way into tight orbits around white dwarfs, but it is unclear whether these planets can survive the journey. So far, no intact planets have been detected in close orbits around white dwarfs. Here we report the observation of a giant planet candidate transiting the white dwarf WD 1856+534 (TIC 267574918) every 1.4 days. We observed and modelled the periodic dimming of the white dwarf caused by the planet candidate passing in front of the star in its orbit. The planet candidate is roughly the same size as Jupiter and is no more than 14 times as massive (with 95 per cent confidence). Other cases of white dwarfs with close brown dwarf or stellar companions are explained as the consequence of common-envelope evolution, wherein the original orbit is enveloped during the red giant phase and shrinks owing to friction. In this case, however, the long orbital period (compared with other white dwarfs with close brown dwarf or stellar companions) and low mass of the planet candidate make common-envelope evolution less likely. Instead, our findings for the WD 1856+534 system indicate that giant planets can be scattered into tight orbits without being tidally disrupted, motivating the search for smaller transiting planets around white dwarfs
Distinct germline genetic susceptibility profiles identified for common non-Hodgkin lymphoma subtypes
Lymphoma risk is elevated for relatives with common non-Hodgkin lymphoma (NHL) subtypes, suggesting shared genetic susceptibility across subtypes. To evaluate the extent of mutual heritability among NHL subtypes and discover novel loci shared among subtypes, we analyzed data from eight genome-wide association studies within the InterLymph Consortium, including 10,629 cases and 9505 controls. We utilized Association analysis based on SubSETs (ASSET) to discover loci for subsets of NHL subtypes and evaluated shared heritability across the genome using Genome-wide Complex Trait Analysis (GCTA) and polygenic risk scores. We discovered 17 genome-wide significant loci (P < 5 × 10−8) for subsets of NHL subtypes, including a novel locus at 10q23.33 (HHEX) (P = 3.27 × 10−9). Most subset associations were driven primarily by only one subtype. Genome-wide genetic correlations between pairs of subtypes varied broadly from 0.20 to 0.86, suggesting substantial heterogeneity in the extent of shared heritability among subtypes. Polygenic risk score analyses of established loci for different lymphoid malignancies identified strong associations with some NHL subtypes (P < 5 × 10−8), but weak or null associations with others. Although our analyses suggest partially shared heritability and biological pathways, they reveal substantial heterogeneity among NHL subtypes with each having its own distinct germline genetic architecture
Recommended from our members
New instruments and techniques in neutron capture studies
Three general topics are addressed. The first deals with crystal diffraction gamma-ray spectrometers, in particular, with the highly productive GAMS spectrometers at the ILL reactor in Grenoble. They are described in detail because of their great potential for producing capture gamma-ray data of the highest quality. Future possibilities for other developments in the area of crystal diffraction spectroscopy of capture gamma rays are also mentioned. Improved neutron beam facilities for capture gamma-ray experiments are discussed within the general framework of the subject of the production of high-quality thermal neutron beams under a variety of conditions. Finally, a magnetic spectrometer for studies of internal conversion electrons emitted after thermal neutron capture, now nearing completion at the BNL High Flux Research Reactor, is described in some detail. Its characteristics are compared with those of the high-performance (n,e) spectrometer BILL at the ILL research reactor in Grenoble. 2 figures. (RWR
Recommended from our members
Enhanced transitions in the (n,) reaction to collective 3- states in nuclei near closed neutron shells
- …