267 research outputs found

    Late-night salivary cortisol may be valuable for assessing treatment response in patients with Cushing’s disease: 12-month, Phase III pasireotide study

    Get PDF
    Measuring salivary cortisol is a simple, convenient and accurate technique with potential value in monitoring patients with hypercortisolism. This analysis reports changes in late-night salivary cortisol (LNSC) during a 12-month, multicentre, Phase III study of patients with Cushing’s disease who were randomized to pasireotide 600 or 900 lg sc bid. LNSC assessment was an exploratory objective based on a single, optional measurement at midnight ± 1 h on the same day as one of the 24-h urinary free cortisol (UFC) measurements. Of 162 enrolled patients, baseline LNSC was measured in 93. Sixty-seven patients had levels above the upper limit of normal (ULN); median baseline levels were 19.7 and 20.7 nmol/L in the groups subsequently randomized to 600 lg (n = 40) and 900 lg (n = 27), respectively. Median LNSC levels decreased from baseline to month 12; median changes in patients who had baseline LNSC [ULN in the 600 and 900 lg groups were -13.4 nmol/L (–52.6 %; n = 19) and -11.8 nmol/L (–56.1 %; n = 14), respectively. LNSC normalized at months 6 and 12 in 25/67 (37.3 %) and 13/67 (19.4 %) patients, respectively; 10/25 and 8/13 patients also had normalized UFC, and 7/25 and 4/13 had partial UFC control (UFC [ULN and C50 % decrease from baseline). There was a moderate correlation (r = 0.55) on the log scale between individual patient LNSC and UFC values when all time points were pooled. Pasireotide decreased LNSC levels during 12 months of treatment. Salivary cortisol may be a simple, convenient biomarker for assessing treatment response in patients with Cushing’s disease

    The Belle II SVD detector

    Get PDF
    The Silicon Vertex Detector (SVD) is one of the main detectors in the Belle II experiment at KEK, Japan. In combination with a pixel detector, the SVD determines precise decay vertex and low-momentum track reconstruction. The SVD ladders are being developed at several institutes. For the development of the tracking algorithm as well as the performance estimation of the ladders, beam tests for the ladders were performed. We report an overview of the SVD development, its performance measured in the beam test, and the prospect of its assembly and commissioning until installation

    Performance studies of the Belle II Silicon Vertex Detector with data taken at the DESY test beam in April 2016

    Get PDF
    Belle II is a multipurpose detector currently under construction which will be operated at the next generation B-factory SuberKEKB in Japan. Its main devices for the vertex reconstruction are the Silicon Vertex Detector (SVD) and the Pixel Detector (PXD). In April 2016 a sector of the Belle II SVD and PXD have been tested in a beam of high energetic electrons at the test beam facility at DESY Hamburg (Germany). We report here the results for the hit efficiency estimation and the measurement of the resolution for the Belle II silicon vertex etector. We find that the hit efficiencies are on average above 99.5% and that the measured resolution is within the expectations

    Performance studies of the Belle II Silicon Vertex Detector with data taken at the DESY test beam in April 2016

    Get PDF
    Belle II is a multipurpose detector currently under construction which will be operated at the next generation B-factory SuberKEKB in Japan. Its main devices for the vertex reconstruction are the Silicon Vertex Detector (SVD) and the Pixel Detector (PXD). In April 2016 a sector of the Belle II SVD and PXD have been tested in a beam of high energetic electrons at the test beam facility at DESY Hamburg (Germany). We report here the results for the hit efficiency estimation and the measurement of the resolution for the Belle II silicon vertex etector. We find that the hit efficiencies are on average above 99.5% and that the measured resolution is within the expectations

    Risk factors and management of pasireotide-associated hyperglycemia in acromegaly

    Get PDF
    Pasireotide, a multireceptor-targeted somatostatin analog with highest affinity for somatostatin receptor subtype (SST) 5, has demonstrated superior efficacy over the SST2-preferential somatostatin analogs octreotide and lanreotide. The safety profile is similar to those of octreotide and lanreotide, except for a higher frequency and degree of hyperglycemia. This analysis investigated baseline characteristics and occurrence and management of hyperglycemia during pasireotide treatment in patients with acromegaly treated in two prospective clinical studies, SOM230C2305 (C2305) and SOM230C2402 (C2402; PAOLA)

    Belle-II VXD radiation monitoring and beam abort with sCVD diamond sensors

    Get PDF
    The Belle-II VerteX Detector (VXD) has been designed to improve the performances with respect to Belle and to cope with an unprecedented luminosity of View the MathML source8 71035cm 122s 121 achievable by the SuperKEKB. Special care is needed to monitor both the radiation dose accumulated throughout the life of the experiment and the instantaneous radiation rate, in order to be able to promptly react to sudden spikes for the purpose of protecting the detectors. A radiation monitoring and beam abort system based on single-crystal diamond sensors is now under an active development for the VXD. The sensors will be placed in several key positions in the vicinity of the interaction region. The severe space limitations require a challenging remote readout of the sensors
    • …
    corecore