    Fabric phase sorptive extraction: A paradigm shift approach in analytical and bioanalytical sample preparation

    Get PDF
    Fabric phase sorptive extraction (FPSE) is an evolutionary sample preparation approach which was introduced in 2014, meeting all green analytical chemistry (GAC) requirements by implementing a natural or synthetic permeable and flexible fabric substrate to host a chemically coated sol–gel organic–inorganic hybrid sorbent in the form of an ultra-thin coating. This construction results in a versatile, fast, and sensitive micro-extraction device. The user-friendly FPSE membrane allows direct extraction of analytes with no sample modification, thus eliminating/minimizing the sample pre-treatment steps, which are not only time consuming, but are also considered the primary source of major analyte loss. Sol–gel sorbent-coated FPSE membranes possess high chemical, solvent, and thermal stability due to the strong covalent bonding between the fabric substrate and the sol–gel sorbent coating. Subsequent to the extraction on FPSE membrane, a wide range of organic solvents can be used in a small volume to exhaustively back-extract the analytes after FPSE process, leading to a high preconcentration factor. In most cases, no solvent evaporation and sample reconstitution are necessary. In addition to the extensive simplification of the sample preparation workflow, FPSE has also innovatively combined the extraction principle of two major, yet competing sample preparation techniques: Solid phase extraction (SPE) with its characteristic exhaustive extraction, and solid phase microextraction (SPME) with its characteristic equilibrium driven extraction mechanism. Furthermore, FPSE has offered the most comprehensive cache of sorbent chemistry by successfully combining almost all of the sorbents traditionally used exclusively in either SPE or in SPME. FPSE is the first sample preparation technique to exploit the substrate surface chemistry that complements the overall selectivity and the extraction efficiency of the device. As such, FPSE indeed represents a paradigm shift approach in analytical/bioanalytical sample preparation. Furthermore, an FPSE membrane can be used as an SPME fiber or as an SPE disk for sample preparation, owing to its special geometric advantage. So far, FPSE has overwhelmingly attracted the interest of the separation scientist community, and many analytical scientists have been developing new methodologies by implementing this cutting-edge technique for the extraction and determination of many analytes at their trace and ultra-trace level concentrations in environmental samples as well as in food, pharmaceutical, and biological samples. FPSE offers a total sample preparation solution by providing neutral, cation exchanger, anion exchanger, mixed mode cation exchanger, mixed mode anion exchanger, zwitterionic, and mixed mode zwitterionic sorbents to deal with any analyte regardless of its polarity, ionic state, or the sample matrix where it resides. Herein we present the theoretical background, synthesis, mechanisms of extraction and desorption, the types of sorbents, and the main applications of FPSE so far according to different sample categories, and to briefly show the progress, advantages, and the main principles of the proposed technique

    Multi-element analysis based on an automated on-line microcolumn separation/preconcentration system using a novel sol-gel thiocyanatopropyl-functionalized silica sorbent prior to ICP-AES for environmental water samples

    Get PDF
    A sol-gel thiocyanatopropyl-functionalized silica sorbent was synthesized and employed for an automated on-line microcolumn preconcentration platform as a front-end to inductively coupled plasma atomic emission spectroscopy (ICP-AES) for the simultaneous determination of Cd(II), Pb(II), Cu(II), Cr(III), Co(II), Ni(II), Zn(II), Mn(II), Hg(II), and V(II). The developed system is based on an easy-to-repack microcolumn construction integrated into a flow injection manifold coupled directly to ICP-AES’s nebulizer. After on-line extraction/preconcentration of the target analyte onto the surface of the sorbent, successive elution with 1.0 mol L−1 HNO3 was performed. All main chemical and hydrodynamic factors affecting the effectiveness of the system were thoroughly investigated and optimized. Under optimized experimental conditions, for 60 s preconcentration time, the enhancement factor achieved for the target analytes was between 31 to 53. The limits of detection varied in the range of 0.05 to 0.24 ÎŒg L−1, while the limits of quantification ranged from 0.17 to 0.79 ÎŒg L−1. The precision of the method was expressed in terms of relative standard deviation (RSD%) and was less than 7.9%. Furthermore, good method accuracy was observed by analyzing three certified reference materials. The proposed method was also successfully employed for the analysis of environmental water samples

    Fabric phase sorptive extraction of selected steroid hormone residues in commercial raw milk followed by ultra-high-performance liquid chromatography–tandem mass spectrometry

    Get PDF
    Hormones in edible matrices, such as milk, are a subject of concern because of their adverse effects on the endocrine system and cell signaling and the consequent disruption of homeostasis in human consumers. Therefore, the assessment of the presence of hormones in milk as potential endocrine-disrupting compounds is warranted. However, the complexity of milk as a sample matrix and the ultra-low concentration of hormones pose significant analytical challenges. Fabric phase sorptive extraction (FPSE) has emerged as a powerful analytical technique for the extraction of emerging pollutants from complex aqueous matrices. FPSE allows for substantially simplified sample handling and short extraction and desorption times, as well as the decreased use of organic solvents. It is considered a green alternative to traditional extraction methodologies. In this work, the FPSE technique was evaluated to perform the simultaneous extraction of 15 steroid hormones from raw milk without employing any sample pretreatment steps. Clean and preconcentrated hormone solutions obtained from FPSE of raw milk were analyzed using ultra-high-performance liquid chromatography–tandem mass spectrometry to achieve low detection limits, which ranged from 0.047 to 1.242 ng·mL−1. Because of the presence of many interferents in milk, such as proteins, lipids, and sugar, the effect of fat content on the extraction procedure was also thoroughly studied. Additionally, for the first time, the effect of lactose on the extraction of steroid hormones was evaluated, and the results showed that the extraction efficiencies were enhanced in lactose-free samples. Finally, the optimized methodology was applied to commercial samples of cow and goat milk, and no measurable concentrations of the studied hormones were detected in these samples

    Overview of Different Modes and Applications of Liquid Phase-Based Microextraction Techniques

    Get PDF
    Liquid phase-based microextraction techniques (LP”ETs) have attracted great attention from the scientific community since their invention and implementation mainly due to their high effi ciency, low solvent and sample amount, enhanced selectivity and precision, and good reproducibility for a wide range of analytes. This review explores the different possibilities and applications of LP”ETs including dispersive liquid–liquid microextraction (DLLME) and single-drop microextrac tion (SDME), highlighting its two main approaches, direct immersion-SDME and headspace-SDME, hollow-fiber liquid-phase microextraction (HF-LPME) in its two- and three-phase device modes using the donor–acceptor interactions, and electro membrane extraction (EME). Currently, these LP”ETs are used in very different areas of interest, from the environment to food and beverages, pharma ceutical, clinical, and forensic analysis. Several important potential applications of each technique will be reported, highlighting its advantages and drawbacks. Moreover, the use of alternative and efficient “green” extraction solvents including nanostructured supramolecular solvents (SUPRASs, deep eutectic solvents (DES), and ionic liquids (ILs)) will be discussed.info:eu-repo/semantics/publishedVersio

    Fabric phase sorptive extraction followed by ultra-performance liquid chromatography-tandem mass spectrometry for the determination of fungicides and insecticides in wine

    Get PDF
    This is the Author’s Accepted Manuscript of the following article: PĂ©rez-MayĂĄn, L., RodrĂ­guez, I., Ramil, M., Kabir, A., Furton, K., & Cela, R. (2019). Fabric phase sorptive extraction followed by ultra-performance liquid chromatography-tandem mass spectrometry for the determination of fungicides and insecticides in wine. Journal Of Chromatography A, 1584, 13-23. doi: 10.1016/j.chroma.2018.11.025In this work, fabric phase sorptive extraction (FPSE) is investigated for the extraction and preconcentration of ultra-trace level residues of fungicides (19 compounds) and insecticides (3 species) in wine samples. Subsequently, the preconcentrated analytes are selectively determined using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Parameters affecting the efficiency and repeatability of the extraction are evaluated in depth; moreover, the proposed method is characterized in terms of linear response range, trueness, precision and limits of quantification (LOQs). The set-up of the extraction process and the type of coating were the variables exerting the most prominent effects in the repeatability and the yield of the extraction, respectively. Under optimized conditions, samples (10 mL of wine diluted with the same volume of ultrapure water) were extracted with a small amount of cellulose fabric (3 discs with 4 mm of diameter: total surface 0.38 cm2) coated with a sol-gel polyethylene glycol sorbent (sorbent amount 3.3 mg), immersed in the diluted sample, without being in direct contact with the PTFE covered magnetic stir bar. Following the overnight extraction step, analytes were quantitatively recovered using only 0.3 mL of an ACN-MeOH (80:20) mixture. Under equilibrium sampling conditions, the linear response range of the method varied from 0.2 to 200 ng mL−1, with limits of quantification (LOQs) between 0.03 and 0.3 ng mL−1. Relative recoveries ranged from 77 ± 6% to 118 ± 4%, and from 87 ± 4% to 121 ± 6% for red and white wines, respectively. Application of the optimized method to commercial wines demonstrated the existence of up to 9 out of 22 investigated compounds in the same wine sample. The compound identified at the highest concentration was iprovalicarb (IPR), with a value of 130 ± 9 ng mL−1 in a commercial white wineThis study has been supported by the Spanish Government, Xunta de Galicia and E.U. FEDER funds (projects CTQ2015-68660-P and GRC-ED431C). L.P-M acknowledges a FPU contract to the Spanish Ministry of EducationS

    Determination of intact parabens in the human plasma of cancer and non-cancer patients using a validated fabric phase sorptive extraction reversed-phase liquid chromatography method with uv detection

    Get PDF
    Parabens have been widely employed as preservatives since the 1920s for extending the shelf life of foodstuffs, medicines, and daily care products. Given the fact that there are some legitimate concerns related to their potential multiple endocrine-disrupting properties, the development of novel bioanalytical methods for their biomonitoring is crucial. In this study, a fabric phase sorptive extraction reversed-phase liquid chromatography method coupled with UV detection (FPSE-HPLC-UV) was developed and validated for the quantitation of seven parabens in human plasma samples. Chromatographic separation of the seven parabens and p-hydroxybenzoic acid was achieved on a semi-micro Spherisorb ODS1 analytical column under isocratic elution using a mobile phase containing 0.1% (v/v) formic acid and 66% 49 mM ammonium formate aqueous solution in acetonitrile at flow rate 0.25 mL min−1 with a 24-min run time for each sample. The method was linear at a concentration range of 20 to 500 ng mL−1 for the seven parabens under study in human plasma samples. The efficiency of the method was proven with the analysis of 20 human plasma samples collected from women subjected to breast cancer surgery and to reconstructive and aesthetic breast surgery. The highest quantitation rates in human plasma samples from cancerous cases were found for methylparaben and isobutylparaben with average plasma concentrations at 77 and 112.5 ng mL−1 . The high concentration levels detected agree with previous findings for some of the parabens and emphasize the need for further epidemiological research on the possible health effects of the use of these compounds

    Determination of synthetic opioids in oral fluid samples using fabric phase sorptive extraction and gas chromatography-mass spectrometry

    Get PDF
    New psychoactive substances (NPS) continue to emerge in the drug market every year, becoming a global threat to public health and safety. These compounds are mostly synthetic cannabinoids and designer cathinones. However, synthetic opioids have appeared on the recreational drug markets in recent years, particularly fentanyl and its derivatives (“fentanyls”). Fentanyl and its analogs are related to harmful intoxications and an increase in opioid-related mortality in many countries, such as in the United States and Europe in the last years. Taking the drug related global crisis into consideration, this work developed and validated an effective and sensitive method based on fabric phase sorptive extraction (FPSE) followed by gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of 11 fentanyl analogs in oral fluid samples. The extraction was carried out using a sol-gel Carbowax 20 M sorbent immobilized on 100% cellulose fabric substrate and using ethyl acetate as the desorption solvent. The limits of detection (LODs) and quantification (LOQs) ranged from 1 to 15 ng mL−1 and 5 to 50 ng mL−1, respectively. Intra-day and inter-day precision were found within 8.2% and 8.6%, respectively, while accuracy ranged from -5.5 to 9.1%, in accordance with the established criteria. The absolute recovery values were in the range of 94.5%–109.1%. The validated method demonstrated its great potential to detect and quantify fentanyl analogs in possible forensic work and off-site analysis in road traffic casesThis work was supported by the Spanish Ministry of Science, Innovation, and Universities (Project RTI2018‐096450‐B‐I00) and FEDER fundsS

    Green extraction techniques as advanced sample preparation approaches in biological, food, and environmental matrices: A review

    Get PDF
    Green extraction techniques (GreETs) emerged in the last decade as greener and sustainable alternatives to classical sample preparation procedures aiming to improve the selectivity and sensitivity of analytical methods, simultaneously reducing the deleterious side effects of classical extraction techniques (CETs) for both the operator and the environment. The implementation of improved processes that overcome the main constraints of classical methods in terms of efficiency and ability to minimize or eliminate the use and generation of harmful substances will promote more efficient use of energy and resources in close association with the principles supporting the concept of green chemistry. The current review aims to update the state of the art of some cutting-edge GreETs developed and implemented in recent years focusing on the improvement of the main analytical features, practical aspects, and relevant applications in the biological, food, and environmental fields. Approaches to improve and accelerate the extraction efficiency and to lower solvent consumption, including sorbent-based techniques, such as solid-phase microextraction (SPME) and fabric-phase sorbent extraction (FPSE), and solvent-based techniques (ÎŒQuEChERS; micro quick, easy, cheap, effective, rugged, and safe), ultrasound-assisted extraction (UAE), and microwave-assisted extraction (MAE), in addition to supercritical fluid extraction (SFE) and pressurized solvent extraction (PSE), are highlighted.This research was funded by FCT (Fundação para a CiĂȘncia e a Tecnologia) through the CQM Base Fund, UIDB/00674/2020, Programmatic Fund, UIDP/00674/2020, and CEB—Centre of Biological Engineering, and by ARDITI (AgĂȘncia Regional para o Desenvolvimento da Investigação Tecnologia e Inovação) through the project M1420-01-0145-FEDER-000005, Centro de QuĂ­mica da Madeira (CQM+; Madeira 14-20 Program). The authors also acknowledge FCT and the Madeira 14–20 Program to the Portuguese Mass Spectrometry Network (RNEM) through the PROEQUIPRAM program, M14-20 M1420-01-0145-FEDER-000008). ARDITI is also acknowledged for the postdoctoral fellowship granted to J.A.M.P. (Project M1420-09-5369-FSE-000001).info:eu-repo/semantics/publishedVersio

    Polytetrahydrofuran-and Dendrimer-Based Novel Sol-Gel Coatings for Capillary Microextraction (CME) Providing Parts Per Trillion (ppt) and Parts Per Quadrillion (ppq) Level Detection Limits in Conjunction With Gas Chromatography and Flame Ionization Detection (FID)

    Get PDF
    Sol-gel capillary microextraction (CME) is a new direction in solvent-free extraction and preconcentration of trace analytes. CME presents significant interest in environmental, pharmaceutical, petrochemical, biomedical, agricultural, food, flavor, and a host of other important areas. Sol-gel CME utilizes advanced material properties of organic-inorganic hybrid sol-gel polymers to perform efficient extraction and enrichment of target analytes from a variety of matrices. In this dissertation, two novel sol-gel coatings were developed for CME: (a) sol-gel benzyl-terminated dendrimer coating, and (b) sol-gel polytetrahydrofuran (poly-THF) coating. A detailed investigation was conducted to evaluate the performance of the newly developed sol-gel coatings in solvent-free extraction of a wide range of polar and nonpolar analytes. Sol-gel chemistry was used to chemically immobilize dendrimer- and poly-THFbased hybrid organic-inorganic coatings on fused silica capillary inner surface. The solgel coatings were created using a coating solution containing a sol-gel active organic component (dendrimer or poly-THF), a sol-gel precursor (methyltrimethoxysilane, MTMOS), a sol-gel catalyst (trifluoroacetic acid, TFA, 5% water) and a deactivating reagent (hexamethyldisilazane, HMDS). Sol-gel reactions were conducted inside a hydrothermally treated fused silica capillary for 60 min. A wall-bonded sol-gel coating was formed via condensation of silanol groups residing on the capillary inner surface with those on the sol-gel network fragments evolving in close vicinity of the capillary walls. Due to the strong chemical bonding with capillary inner walls, these sol-gel coatings showed excellent thermal and solvent stability in CME in hyphenation with gas chromatography (GC). Using a Flame ionization detector (FID), low parts per trillion (ppt) and parts per quadrillion (ppq) level detection limits were achieved in CME-GC for both polar and nonpolar analytes including polycyclic aromatic hydrocarbons (PAHs), aldehydes, ketones, phenols, and alcohols. The sol-gel coatings were found to be effective in carrying out simultaneous extraction of both polar and nonpolar analytes from the same sample. To our knowledge, two publications resulting from this research [A. Kabir et al. J. Chromatogr. A 1034 (2004) 1-11; A Kabir et al. J. Chromatogr. A 1047 (2004) 1-13] represent the first reports on the development and use of sol-gel dendrimer and sol-gel poly-THF coatings in analytical microextraction
    • 