253 research outputs found

    Rapid molecular tests for tuberculosis and tuberculosis drug resistance: a qualitative evidence synthesis of recipient and provider views

    Get PDF
    BACKGROUND: Programmes that introduce rapid molecular tests for tuberculosis and tuberculosis drug resistance aim to bring tests closer to the community, and thereby cut delay in diagnosis, ensure early treatment, and improve health outcomes, as well as overcome problems with poor laboratory infrastructure and inadequately trained personnel. Yet, diagnostic technologies only have an impact if they are put to use in a correct and timely manner. Views of the intended beneficiaries are important in uptake of diagnostics, and their effective use also depends on those implementing testing programmes, including providers, laboratory professionals, and staff in health ministries. Otherwise, there is a risk these technologies will not fit their intended use and setting, cannot be made to work and scale up, and are not used by, or not accessible to, those in need. OBJECTIVES: To synthesize end-user and professional user perspectives and experiences with low-complexity nucleic acid amplification tests (NAATs) for detection of tuberculosis and tuberculosis drug resistance; and to identify implications for effective implementation and health equity. SEARCH METHODS: We searched MEDLINE, Embase, CINAHL, PsycInfo and Science Citation Index Expanded databases for eligible studies from 1 January 2007 up to 20 October 2021. We limited all searches to 2007 onward because the development of Xpert MTB/RIF, the first rapid molecular test in this review, was completed in 2009. SELECTION CRITERIA: We included studies that used qualitative methods for data collection and analysis, and were focused on perspectives and experiences of users and potential users of low-complexity NAATs to diagnose tuberculosis and drug-resistant tuberculosis. NAATs included Xpert MTB/RIF, Xpert MTB/RIF Ultra, Xpert MTB/XDR, and the Truenat assays. Users were people with presumptive or confirmed tuberculosis and drug-resistant tuberculosis (including multidrug-resistant (MDR-TB)) and their caregivers, healthcare providers, laboratory technicians and managers, and programme officers and staff; and were from any type of health facility and setting globally. MDR-TB is tuberculosis caused by resistance to at least rifampicin and isoniazid, the two most effective first-line drugs used to treat tuberculosis. DATA COLLECTION AND ANALYSIS: We used a thematic analysis approach for data extraction and synthesis, and assessed confidence in the findings using GRADE CERQual approach. We developed a conceptual framework to illustrate how the findings relate. MAIN RESULTS: We found 32 studies. All studies were conducted in low- and middle-income countries. Twenty-seven studies were conducted in high-tuberculosis burden countries and 21 studies in high-MDR-TB burden countries. Only one study was from an Eastern European country. While the studies covered a diverse use of low-complexity NAATs, in only a minority of studies was it used as the initial diagnostic test for all people with presumptive tuberculosis. We identified 18 review findings and grouped them into three overarching categories. Critical aspects users value People with tuberculosis valued reaching diagnostic closure with an accurate diagnosis, avoiding diagnostic delays, and keeping diagnostic-associated cost low. Similarly, healthcare providers valued aspects of accuracy and the resulting confidence in low-complexity NAAT results, rapid turnaround times, and keeping cost to people seeking a diagnosis low. In addition, providers valued diversity of sample types (for example, gastric aspirate specimens and stool in children) and drug resistance information. Laboratory professionals appreciated the improved ease of use, ergonomics, and biosafety of low-complexity NAATs compared to sputum microscopy, and increased staff satisfaction. Challenges reported to realizing those values People with tuberculosis and healthcare workers were reluctant to test for tuberculosis (including MDR-TB) due to fears, stigma, or cost concerns. Thus, low-complexity NAAT testing is not implemented with sufficient support or discretion to overcome barriers that are common to other approaches to testing for tuberculosis. Delays were reported at many steps of the diagnostic pathway owing to poor sample quality; difficulties with transporting specimens; lack of sufficient resources; maintenance of low-complexity NAATs; increased workload; inefficient work and patient flows; over-reliance on low-complexity NAAT results in lieu of clinical judgement; and lack of data-driven and inclusive implementation processes. These challenges were reported to lead to underutilization.  Concerns for access and equity The reported concerns included sustainable funding and maintenance and equitable use of resources to access low-complexity NAATs, as well as conflicts of interest between donors and people implementing the tests. Also, lengthy diagnostic delays, underutilization of low-complexity NAATs, lack of tuberculosis diagnostic facilities in the community, and too many eligibility restrictions hampered access to prompt and accurate testing and treatment. This was particularly the case for vulnerable groups, such as children, people with MDR-TB, or people with limited ability to pay. We had high confidence in most of our findings. AUTHORS' CONCLUSIONS: Low-complexity diagnostics have been presented as a solution to overcome deficiencies in laboratory infrastructure and lack of skilled professionals. This review indicates this is misleading. The lack of infrastructure and human resources undermine the added value new diagnostics of low complexity have for recipients and providers. We had high confidence in the evidence contributing to these review findings. Implementation of new diagnostic technologies, like those considered in this review, will need to tackle the challenges identified in this review including weak infrastructure and systems, and insufficient data on ground level realities prior and during implementation, as well as problems of conflicts of interest in order to ensure equitable use of resources

    Feasibility of magnetic bead technology for concentration of mycobacteria in sputum prior to fluorescence microscopy

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Direct sputum smear microscopy is the mainstay of TB diagnosis in most low and middle income countries, and is highly specific for <it>Mycobacterium tuberculosis </it>in such settings. However it is limited by low sensitivity, particularly in HIV co-infected patients. Concentration by centrifugation has been reported to be more sensitive than direct smear preparation, but is only suitable for referral laboratories. Simpler concentration methods that could be applied in peripheral laboratories are urgently needed.</p> <p>Methods</p> <p>We evaluated the feasibility of an early prototype ligand-coated magnetic bead technology to concentrate <it>M. tuberculosis </it>prior to detection by LED-based fluorescence microscopy compared with direct Ziehl-Neelsen microscopy and direct and concentrated fluorescence microscopy in a reference laboratory in Kampala, Uganda. Results were compared with MGIT 960 liquid culture and Lowenstein-Jensen culture.</p> <p>Results</p> <p>Compared to culture, concentrated FM had significantly higher sensitivity than direct ZN (74.8% and 51.4%), magnetic bead-FM (65.4%) and direct FM (58.9%). The sensitivity of magnetic bead FM was significantly higher than direct ZN (p < 0.001) but not significantly higher than direct FM (p = 0.210). The specificity of magnetic bead FM and concentrated FM was significantly lower than direct ZN (88.6%, 94.3% and 98.9% respectively) and direct FM (99.4%). There was no significant difference in specificity between magnetic bead FM and concentrated FM. Allowing for blinded resolution of discrepant results, the specificity of magnetic bead FM increased to 93.1%. Direct microscopy was simpler than concentrated FM and Magnetic bead FM which both had a similar number of steps.</p> <p>Conclusion</p> <p>The sensitivity of the early prototype magnetic bead FM was lower than concentrated FM, similar to direct FM, and significantly higher than direct ZN. Both magnetic bead and concentration by centrifugation led to reduced specificity compared with the direct smear methods. Some magnetic bead FM false positive results were not easily explained and should be further investigated. The prototype version of the magnetic bead procedure tested here was of similar complexity to concentration by centrifugation. As such, if the sensitivity of the magnetic bead FM could be improved in future versions of the technology, this may offer a viable alternative to centrifugation.</p

    Challenges of tuberculosis management in high and low prevalence countries in a mobile world

    Get PDF
    This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.In this issue of the PCRJ, Bishara et al. 1 present a case report about the treatment of a pregnant woman with tuberculosis (TB). She had emigrated from a country with a high prevalence of TB to one with a lower prevalence. This presented a challenge to her physicians who were faced with identifying and treating close contacts who were also infected. This Perspective article explores in more depth some of the questions raised by this case report. It discusses the role of primary care physicians in low prevalence countries who can implement evidence-based screening programmes, it discusses effective strategies for the diagnosis and treatment of TB in countries with high TB prevalence, and it presents insights from medical anthropology that can help practitioners overcome the barriers to TB diagnosis, treatment and screening described in the case report

    Validation of the ALS Assay in Adult Patients with Culture Confirmed Pulmonary Tuberculosis

    Get PDF
    BACKGROUND: We have earlier shown that Bacille Calmette-Guérin (BCG) vaccine-specific IgG Antibodies in Lymphocyte Supernatant (ALS) can be used for diagnosis of active tuberculosis (TB) in adults and children. METHODOLOGY/PRINCIPAL FINDINGS: The ALS method was validated in a larger cohort (n = 212) of patients with suspicion of pulmonary TB using multiple antigens (BCG, LAM, TB15.3, TB51A, CFP10-ESAT6-A, CFP, CW) from Mycobacterium tuberculosis. The sensitivity and specificity of the ALS assay was calculated using non-TB patients as controls. The sensitivity and the specificity were highest with BCG vaccine (90% and 88% respectively) followed by LAM (89% and 87% respectively). Simultaneous assessment of multiple antigen-specific antibodies increased sensitivity (91%) and specificity (88%). Using higher lymphocyte count in smaller volume of culture media increased detection and reduced the assay duration to ∼30 hrs. Twenty one patients with clinical findings strongly suggestive of TB finally diagnosed as non-TB patients were positive by the ALS assay, of which 9 (43%) were positive for 7 antigens and 19 (90%) for at least 3 antigens. CONCLUSIONS/SIGNIFICANCE: Our findings show that simultaneous detection of antigens improves the diagnostic potential of the ALS assay; the modified method increases sensitivity and can provide results in <48 hours, and enable detection of some cases of pulmonary TB that are not detectable by standard methods

    British HIV Association guidelines for the management of tuberculosis in adults living with HIV 2019

    Get PDF
    The overall purpose of these guidelines is to help physicians manage adults with tuberculosis (TB)/human immunodeficiency virus (HIV) co‐infection. Recommendations for the treatment of TB in HIV‐positive adults are similar to those in HIV‐negative adults. Of note, the term “HIV” refers to HIV‐1 throughout these guidelines

    Comparison of LED and Conventional Fluorescence Microscopy for Detection of Acid Fast Bacilli in a Low-Incidence Setting

    Get PDF
    INTRODUCTION: Light emitting diode fluorescence microscopes have many practical advantages over conventional mercury vapour fluorescence microscopes, which would make them the preferred choice for laboratories in both low- and high-resource settings, provided performance is equivalent. METHODS: In a nested case-control study, we compared diagnostic accuracy and time required to read slides with the Zeiss PrimoStar iLED, LW Scientific Lumin, and a conventional fluorescence microscope (Leica DMLS). Mycobacterial culture was used as the reference standard, and subgroup analysis by specimen source and organism isolated were performed. RESULTS: There was no difference in sensitivity or specificity between the three microscopes, and agreement was high for all comparisons and subgroups. The Lumin and the conventional fluorescence microscope were equivalent with respect to time required to read smears, but the Zeiss iLED was significantly time saving compared to both. CONCLUSIONS: Light emitting diode microscopy should be considered by all tuberculosis diagnostic laboratories, including those in high income countries, as a replacement for conventional fluorescence microscopes. Our findings provide support to the recent World Health Organization policy recommending that conventional fluorescence microscopy be replaced by light emitting diode microscopy using auramine staining in all settings where fluorescence microscopy is currently used

    Retooling National TB Control Programmes (NTPs) with New Diagnostics: The NTP Perspective

    Get PDF
    Background: A delay is evident between the development of new policies on TB diagnostics and their implementation at country level. The Stop TB Partnership would benefit from information from national TB program (NTP) managers on progress towards implementation of new recommendations as well as the opportunities and challenges encountered in the process. Methods and Findings: To solicit information on the introduction of new TB diagnostics at country level, questionnaires were sent out to NTP managers of high-burden TB countries and a subset of managers was interviewed. The results indicate that about 50 % of high-burden TB countries are using the TB diagnostic tools newly recommended by the World Health Organization (WHO). Most NTP managers reported that new diagnostics would only be implemented when officially endorsed by the WHO. All countries have plans to adopt newly endorsed diagnostics at reference laboratory level, while approaches to optimize smear microscopy at lower levels of the health service are given less attention. NTP managers reported diverse challenges to the implementation of new diagnostics. Conclusions: More information on the obstacles and advantages of introducing new diagnostic tools should be provided to NTP managers to ensure the rational adoption of new diagnostics. A single recommendation covering the introduction of a package of diagnostic tools might be preferable to NTP managers and facilitate implementation in high-burden TB countries

    Direct microscopy versus sputum cytology analysis and bleach sedimentation for diagnosis of tuberculosis: a prospective diagnostic study.

    Get PDF
    ABSTRACT: BACKGROUND: Diagnostic options for pulmonary tuberculosis in resource-poor settings are commonly limited to smear microscopy. We investigated whether bleach concentration by sedimentation and sputum cytology analysis (SCA) increased the positivity rate of smear microscopy for smear-positive tuberculosis. METHODS: We did a prospective diagnostic study in a Medecins Sans Frontieres-supported hospital in Mindouli, Republic of Congo. Three sputum samples were obtained from 280 consecutive pulmonary tuberculosis suspects, and were processed according to WHO guidelines for direct smear microscopy. The remainder of each sputum sample was homogenised with 2.6% bleach, sedimented overnight, smeared, and examined blinded to the direct smear result for acid-fast bacilli (AFB). All direct smears were assessed for quality by SCA. If a patient produced fewer than three good-quality sputum samples, further samples were requested. Sediment smear examination was performed independently of SCA result on the corresponding direct smear. Positivity rates were compared using McNemar's test. RESULTS: Excluding SCA, 43.2% of all patients were diagnosed as positive on direct microscopy of up to three samples. 47.9% were diagnosed on sediment microscopy, with 48.2% being diagnosed on direct microscopy, sediment microscopy, or both. The positivity rate increased from 43.2% to 47.9% with a case definition of one positive smear ([greater than or equal to]1 AFB/100 high power fields) of three, and from 42.1% to 43.9% with two positive smears. SCA resulted in 87.9% of patients producing at least two good-quality sputum samples, with 75.7% producing three or more. Using a case definition of one positive smear, the incremental yield of bleach sedimentation was 14/121, or 11.6% (95% CI 6.5-18.6, p=0.001) and in combination with SCA was 15/121, or 12.4% (95% CI 7.1-19.6, p=0.002). Incremental yields with two positive smears were 5/118, or 4.2% (95% CI 1.4-9.6, p=0.062) and 7/118, or 5.9% (95% CI 2.4-11.8, p=0.016), respectively. CONCLUSIONS: The combination of bleach sedimentation and SCA resulted in significantly increased microscopy positivity rates with a case definition of either one or two positive smears. Implementation of bleach sedimentation led to a significant increase in the diagnosis of smear-positive patients. Implementation of SCA did not result in significantly increased diagnosis of tuberculosis, but did result in improved sample quality. Requesting extra sputum samples based on SCA results, combined with bleach sedimentation, could significantly increase the detection of smear-positive patients if routinely implemented in resource-limited settings where gold standard techniques are not available. We recommend that a pilot phase is undertaken before routine implementation to determine the impact in a particular context
    corecore