2,666 research outputs found
Relativistic calculations of the charge-transfer probabilities and cross sections for low-energy collisions of H-like ions with bare nuclei
A new method for solving the time-dependent two-center Dirac equation is
developed. The time-dependent Dirac wave function is represented as a sum of
atomic-like Dirac-Sturm orbitals, localized at the ions. The atomic orbitals
are obtained by solving numerically the finite-difference one-center Dirac and
Dirac-Sturm equations with the potential which is the sum of the exact
reference-nucleus potential and a monopole-approximation potential from the
other nucleus. An original procedure to calculate the two-center integrals with
these orbitals is proposed. The approach is tested by calculations of the
charge transfer and ionization cross sections for the H(1s)--proton collisions
at proton energies from 1 keV to 100 keV. The obtained results are compared
with related experimental and other theoretical data. To investigate the role
of the relativistic effects, the charge transfer cross sections for the
Ne^{9+}(1s)--Ne^{10+} (at energies from 0.1 to 10 MeV/u) and
U^{91+}(1s)--U^{92+} (at energies from 6 to 10 MeV/u) collisions are calculated
in both relativistic and nonrelativistic cases.Comment: 39 pages, 6 tables, 7 figure
First Energy and Angle differential Measurements of e^+e^- -pairs emitted by Internal Pair Conversion of excited Heavy Nuclei
We present the first energy and angle resolved measurements of e+e- pairs
emitted from heavy nuclei (Z>=40) at rest by internal pair conversion (IPC) of
transitions with energies of less than 2MeV as well as recent theoretical
results using the DWBA method, which takes full account of relativistic
effects, magnetic substates and finite size of the nucleus. The 1.76MeV E0
transition in Zr90 (Sr source) and the 1.77MeV M1 transition in Pb207 (Bi
source) have been investigated experimentally using the essentially improved
set-up at the double-ORANGE beta-spectrometer of GSI. The measurements prove
the capability of the setup to cleanly identify the IPC pairs in the presence
of five orders of magnitude higher beta- and gamma background from the same
source and to yield essentially background-free sum spectra despite the large
background. Using the ability of the ORANGE setup to directly determine the
opening angle of the e+e- pairs, the angular correlation of the emitted pairs
was measured. In the Zr90 case the correlation could be deduced for a wide
range of energy differences of the pairs. The Zr90 results are in good
agreement with recent theory. The angular correlation deduced for the M1
transition in Pb207 is in strong disagreement with theoretical predictions
derived within the Born approximation and shows almost isotropic character.
This is again in agreement with the new theoretical results.Comment: LaTeX, 28 pages incl. 10 PS figures; Accepted by Z.Phys.
Performance of the PADME calorimeter prototype at the DANE BTF
The PADME experiment at the DANE Beam-Test Facility (BTF) aims at
searching for invisible decays of the dark photon by measuring the final state
missing mass in the process , with undetected. The
measurement requires the determination of the 4-momentum of the recoil photon,
performed using a homogeneous, highly segmented BGO crystals calorimeter. We
report the results of the test of a 55 crystals prototype performed
with an electron beam at the BTF in July 2016
Electron gas polarization effect induced by heavy H-like ions of moderate velocities channeled in a silicon crystal
We report on the observation of a strong perturbation of the electron gas
induced by 20 MeV/u U ions and 13 MeV/u Pb ions channeled in
silicon crystals. This collective response (wake effect) in-duces a shift of
the continuum energy level by more than 100 eV, which is observed by means of
Radiative Electron Capture into the K and L-shells of the projectiles. We also
observe an increase of the REC probability by 20-50% relative to the
probability in a non-perturbed electron gas. The energy shift is in agreement
with calculations using the linear response theory, whereas the local electron
density enhancement is much smaller than predicted by the same model. This
shows that, for the small values of the adiabaticity parameter achieved in our
experiments, the density fluctuations are not strongly localized at the
vicinity of the heavy ions
Positron spectra from internal pair conversion observed in {238}U + {181}Ta collisions
We present new results from measurements and simulations of positron spectra,
originating from 238U + 181Ta collisions at beam energies close to the Coulomb
barrier. The measurements were performed using an improved experimental setup
at the double-Orange spectrometer of GSI. Particular emphasis is put on the
signature of positrons from Internal-Pair-Conversion (IPC) processes in the
measured e+ energy spectra, following the de-excitation of electromagnetic
transitions in the moving Ta-like nucleus. It is shown by Monte Carlo
simulations that, for the chosen current sweeping procedure used in the present
experiments, positron emission from discrete IPC transitions can lead to rather
narrow line structures in the measured energy spectra. The measured positron
spectra do not show evidence for line structures within the statistical
accuracy achieved, although expected from the intensities of the observed
transitions (E keV) and theoretical conversion
coefficients. This is due to the reduced detection efficiency for IPC
positrons, caused by the limited spatial and momentum acceptance of the
spectrometer. A comparison with previous results, in which lines have been
observed, is presented and the implications are discussed.Comment: LaTeX, 20 pages including 5 EPS figures; Accepted by Eur. Phys.Jour.
Characterization and Performance of PADME's Cherenkov-Based Small-Angle Calorimeter
The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in
Italy, will search for invisible decays of the hypothetical dark photon via the
process , where the escapes detection. The
dark photon mass range sensitivity in a first phase will be 1 to 24 MeV. We
report here on measurement and simulation studies of the performance of the
Small-Angle Calorimeter, a component of PADME's detector dedicated to rejecting
2- and 3-gamma backgrounds. The crucial requirement is a timing resolution of
less than 200 ps, which is satisfied by the choice of PbF crystals and the
newly released Hamamatsu R13478UV photomultiplier tubes (PMTs). We find a
timing resolution of 81 ps (with double-peak separation resolution of 1.8 ns)
and a single-crystal energy resolution of 5.7%/ with light yield of
2.07 photo-electrons per MeV, using 100 to 400 MeV electrons at the Beam Test
Facility of LNF. We also propose the investigation of a two-PMT solution
coupled to a single PbF crystal for higher-energy applications, which has
potentially attractive features.Comment: 12 pages, 19 figures. v2: added section on radiation damage studie
- âŠ