1,695 research outputs found

    Causes of Death Following PCI Versus CABG in Complex CAD 5-Year Follow-Up of SYNTAX

    Get PDF
    AbstractBackgroundThere are no data available on specific causes of death from randomized trials that have compared coronary artery bypass grafting (CABG) with percutaneous coronary intervention (PCI).ObjectivesThe purpose of this study was to investigate specific causes of death, and its predictors, after revascularization for complex coronary disease in patients.MethodsAn independent Clinical Events Committee consisting of expert physicians who were blinded to the study treatment subclassified causes of death as cardiovascular (cardiac and vascular), noncardiovascular, or undetermined according to the trial protocol. Cardiac deaths were classified as sudden cardiac, related to myocardial infarction (MI), and other cardiac deaths.ResultsIn the randomized cohort, there were 97 deaths after CABG and 123 deaths after PCI during a 5-year follow-up. After CABG, 49.4% of deaths were cardiovascular, with the greatest cause being heart failure, arrhythmia, or other causes (24.6%), whereas after PCI, the majority of deaths were cardiovascular (67.5%) and as a result of MI (29.3%). The cumulative incidence rates of all-cause death were not significantly different between CABG and PCI (11.4% vs. 13.9%, respectively; p = 0.10), whereas there were significant differences in terms of cardiovascular (5.8% vs. 9.6%, respectively; p = 0.008) and cardiac death (5.3% vs. 9.0%, respectively; p = 0.003), which were caused primarily by a reduction in MI-related death with CABG compared with PCI (0.4% vs. 4.1%, respectively; p <0.0001). Treatment with PCI versus CABG was an independent predictor of cardiac death (hazard ratio: 1.55; 95% confidence interval: 1.09 to 2.33; p = 0.045). The difference in MI-related death was seen largely in patients with diabetes, 3-vessel disease, or high SYNTAX (TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries) trial scores.ConclusionsDuring a 5-year follow-up, CABG in comparison with PCI was associated with a significantly reduced rate of MI-related death, which was the leading cause of death after PCI. Treatments following PCI should target reducing post-revascularization spontaneous MI. Furthermore, secondary preventive medication remains essential in reducing events post-revascularization. (TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries [SYNTAX]; NCT00114972

    Effect of dual-tasking on walking and cognitive demands in adults with Alzheimer’s dementia experienced in using a 4-wheeled walker

    Get PDF
    Background Learning to walk with a 4-wheeled walker increases cognitive demands in people with Alzheimer’s dementia (AD). However, it is expected that experience will offset the increased cognitive demand. Current research has not yet evaluated gait in people with AD experienced in using a 4-wheeled walker under complex gait situations. Research question What is the effect of dual-task testing on the spatial-temporal gait parameters and cognitive performance of people with AD experienced with a 4-wheeled walker? Methods Twenty-three adults with mild to moderate AD (87.4 ± 6.2 years, 48 % female) and at least 6 months of walker use experience participated. Three walking configurations: 1) straight path (SP), 2) Groningen Meander Walking Test (GMWT), and 3) Figure of 8 path (F8) were tested under two walking conditions: 1) single-task (walking with aid) and 2) dual-task (walking with aid and completing a cognitive task). Tri-axial accelerometers collected velocity, cadence and stride time variability (STV). Gait and cognitive task cost were the percentage difference between single-task and dual-task conditions. Two-way repeated measures ANOVAs were used to answer the study question. Results A significant interaction between walking configuration and condition was found for velocity (p = 0.002, ω2 = 0.36), cadence (p = 0.04, ω2 = 0.15) and STV (p < 0.001, ω2 = 0.53). Velocity and cadence decreased and STV increased with increasing walking configuration complexity and upon dual-tasking. Dual-task gait and cognitive task cost deteriorated in all walking configurations, but gait was prioritized in the GMWT and F8 configurations. Despite familiarity, experienced walker users with AD exhibit impaired gait when walking in complex situations which increases falls risk. Upon dual-task, individuals with AD self-prioritized a posture-first strategy in complex configurations. Significance Dual-task testing in experienced users results in slower walking, fewer steps and increased STV, which increases falls risk in people with mild to moderate AD and becomes most pronounced in complex environments

    The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat

    Full text link
    We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid helium tank and a smaller superfluid tank, allowing the latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank. Each telescope houses a closed cycle helium-3 adsorption refrigerator that further cools the focal planes down to 300 mK. Liquid helium vapor from the main tank is routed through heat exchangers that cool radiation shields, providing negative thermal feedback. The system performed successfully during a 17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold time of 16.8 days, with 15.9 days occurring during flight.Comment: 15 pgs, 17 fig

    Parity-Violating Electron Scattering from 4He and the Strange Electric Form Factor of the Nucleon

    Full text link
    We have measured the parity-violating electroweak asymmetry in the elastic scattering of polarized electrons from ^4He at an average scattering angle = 5.7 degrees and a four-momentum transfer Q^2 = 0.091 GeV^2. From these data, for the first time, the strange electric form factor of the nucleon G^s_E can be isolated. The measured asymmetry of A_PV = (6.72 +/- 0.84 (stat) +/- 0.21 (syst) parts per million yields a value of G^s_E = -0.038 +/- 0.042 (stat) +/- 0.010 (syst), consistent with zero

    Growing old with the immune system: a study of immunosenescence in the zebra finch (Taeniopygia guttata)

    Get PDF
    Immunosenescence has not received much attention in birds and the few existing studies indicate that the occurrence of immunosenescence and/or its extent may differ between species. In addition, not much information is available on the immunosenescence patterns of different immune parameters assessed simultaneously in both sexes within a single species. The present study reports the results on immunosenescence in innate immunity and both cellular and humoral acquired immunity of both sexes in a captive population of zebra finch (Taeniopygia guttata) using three age groups (approximately 0.2, 2.5 and 5.1 years). Both male and female finches showed an inverse U-shaped pattern in cellular immune function with age, quantified by a PHA response. Males showed stronger responses than females at all ages. In contrast, an increase with age in humoral immunity, quantified through total plasma immunoglobulin Y levels, was found in both sexes. However, our measurements of innate immunity measured through the bacteria-killing ability against Escherichia coli gave inconclusive results. Still, we conclude that both cellular and humoral acquired immunity are susceptible to immunosenescence, and that the sexes differ in cellular immunity

    When we should worry more: Using cognitive bias modification to drive adaptive health behaviour

    Get PDF
    A lack of behavioural engagement in health promotion or disease prevention is a problem across many health domains. In these cases where people face a genuine danger, a reduced focus on threat and low levels of anxiety or worry are maladaptive in terms of promoting protection or prevention behaviour. Therefore, it is possible that increasing the processing of threat will increase worry and thereby enhance engagement in adaptive behaviour. Laboratory studies have shown that cognitive bias modification (CBM) can increase or decrease anxiety and worry when increased versus decreased processing of threat is encouraged. In the current study, CBM for interpretation (CBM-I) is used to target engagement in sun protection behaviour. The goal was to investigate whether inducing a negative rather than a positive interpretation bias for physical threat information can enhance worry elicited when viewing a health campaign video (warning against melanoma skin cancer), and consequently lead to more adaptive behaviour (sun protection). Participants were successfully trained to either adopt a positive or negative interpretation bias using physical threat scenarios. However, contrary to expectations results showed that participants in the positive training condition reported higher levels of worry elicited by the melanoma video than participants in the negative training condition. Video elicited worry was, however, positively correlated with a measure of engagement in sun protection behaviour, suggesting that higher levels of worry do promote adaptive behaviour. These findings imply that more research is needed to determine under which conditions increased versus decreased processing of threat can drive adaptive worry. Various potential explanations for the current findings and suggestions for future research are discussed

    Search for a Technicolor omega_T Particle in Events with a Photon and a b-quark Jet at CDF

    Full text link
    If the Technicolor omega_T particle exists, a likely decay mode is omega_T -> gamma pi_T, followed by pi_T -> bb-bar, yielding the signature gamma bb-bar. We have searched 85 pb^-1 of data collected by the CDF experiment at the Fermilab Tevatron for events with a photon and two jets, where one of the jets must contain a secondary vertex implying the presence of a b quark. We find no excess of events above standard model expectations. We express the result of an exclusion region in the M_omega_T - M_pi_T mass plane.Comment: 14 pages, 2 figures. Available from the CDF server (PS with figs): http://www-cdf.fnal.gov/physics/pub98/cdf4674_omega_t_prl_4.ps FERMILAB-PUB-98/321-

    Measurement of the B0 anti-B0 oscillation frequency using l- D*+ pairs and lepton flavor tags

    Full text link
    The oscillation frequency Delta-md of B0 anti-B0 mixing is measured using the partially reconstructed semileptonic decay anti-B0 -> l- nubar D*+ X. The data sample was collected with the CDF detector at the Fermilab Tevatron collider during 1992 - 1995 by triggering on the existence of two lepton candidates in an event, and corresponds to about 110 pb-1 of pbar p collisions at sqrt(s) = 1.8 TeV. We estimate the proper decay time of the anti-B0 meson from the measured decay length and reconstructed momentum of the l- D*+ system. The charge of the lepton in the final state identifies the flavor of the anti-B0 meson at its decay. The second lepton in the event is used to infer the flavor of the anti-B0 meson at production. We measure the oscillation frequency to be Delta-md = 0.516 +/- 0.099 +0.029 -0.035 ps-1, where the first uncertainty is statistical and the second is systematic.Comment: 30 pages, 7 figures. Submitted to Physical Review

    Search for New Particles Decaying to top-antitop in proton-antiproton collisions at squareroot(s)=1.8 TeV

    Get PDF
    We use 106 \ipb of data collected with the Collider Detector at Fermilab to search for narrow-width, vector particles decaying to a top and an anti-top quark. Model independent upper limits on the cross section for narrow, vector resonances decaying to \ttbar are presented. At the 95% confidence level, we exclude the existence of a leptophobic \zpr boson in a model of topcolor-assisted technicolor with mass M_{\zpr} << 480 \gev for natural width Γ\Gamma = 0.012 M_{\zpr}, and M_{\zpr} << 780 \gev for Γ\Gamma = 0.04 M_{\zpr}.Comment: The CDF Collaboration, submitted to PRL 25-Feb-200
    corecore