151 research outputs found
STAR Barrel Electromagnetic Calorimeter Absolute Calibration Using "Minimum Ionizing Particles" from Collisions at RHIC
The procedure for the STAR Barrel Electromagnetic Calorimeter (BEMC) absolute
calibrations, using penetrating charged particle hits (MIP-hits) from physics
events at RHIC, is presented. Its systematic and statistical errors are
evaluated. It is shown that, using this technique, the equalization and
transfer of the absolute scale from the test beam can be done to a percent
level accuracy in a reasonable amount of time for the entire STAR BEMC.
MIP-hits would also be an effective tool for continuously monitoring the
variations of the BEMC tower's gains, virtually without interference to STAR's
main physics program. The method does not rely on simulations for anything
other than geometric and some other small corrections, and also for estimations
of the systematic errors. It directly transfers measured test beam responses to
operations at RHIC.Comment: 19 pages, 7 figures, Accepted to NIM-
Development of a Momentum Determined Electron Beam in the 1 -45 GeV Range
A beam line for electrons with energies in the range of 1 to 45 GeV, low
contamination of hadrons and muons and high intensity up to 10^6 per
accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A
beam tagging system based on drift chambers with 160 micron resolution was able
to measure relative electron beam momentum precisely. The resolution sigma_p p
was 0.13% at 45 GeV where multiple scattering is negligible. This test beam
setup provided the possibility to study properties of lead tungstate crystals
(PbWO_4) for the BTeV experiment at Fermilab.Comment: 12 pages, 8 figures; work done by the BTeV Electromagnetic
Calorimeter grou
Comparison of Radiation Damage in Lead Tungstate Crystals under Pion and Gamma Irradiation
Studies of the radiation hardness of lead tungstate crystals produced by the
Bogoroditsk Techno-Chemical Plant in Russia and the Shanghai Institute of
Ceramics in China have been carried out at IHEP, Protvino. The crystals were
irradiated by a 40-GeV pion beam. After full recovery, the same crystals were
irradiated using a -ray source. The dose rate profiles along
the crystal length were observed to be quite similar. We compare the effects of
the two types of radiation on the crystals light output.Comment: 10 pages, 8 figures, Latex 2e, 28.04.04 - minor grammatical change
Correlation of Beam Electron and LED Signal Losses under Irradiation and Long-term Recovery of Lead Tungstate Crystals
Radiation damage in lead tungstate crystals reduces their transparency. The
calibration that relates the amount of light detected in such crystals to
incident energy of photons or electrons is of paramount importance to
maintaining the energy resolution the detection system. We report on tests of
lead tungstate crystals, read out by photomultiplier tubes, exposed to
irradiation by monoenergetic electron or pion beams. The beam electrons
themselves were used to measure the scintillation light output, and a blue
light emitting diode (LED) was used to track variations of crystals
transparency. We report on the correlation of the LED measurement with
radiation damage by the beams and also show that it can accurately monitor the
crystals recovery from such damage.Comment: 9 pages, 6 figures, LaTeX2
LED Monitoring System for the BTeV Lead Tungstate Crystal Calorimeter Prototype
We report on the performance of a monitoring system for a prototype
calorimeter for the BTeV experiment that uses Lead Tungstate crystals coupled
with photomultiplier tubes. The tests were carried out at the 70 GeV
accelerator complex at Protvino, Russia.Comment: 12 pages, 8 figures, LaTeX2e, revised versio
Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter
A highly stable monitoring system based on blue and red light emitting diodes
coupled to a distribution network comprised of optical fibers has been
developed for an electromagnetic calorimeter that uses lead tungstate crystals
readout with photomultiplier tubes. We report of the system prototype design
and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has
been achieved during one week of prototype operation.Comment: 10 pages, 6 figures, LaTeX2
Study of Radiation Damage in Lead Tungstate Crystals Using Intense High Energy Beams
We report on the effects of radiation on the light output of lead tungstate
crystals. The crystals were irradiated by pure, intense high energy electron
and hadron beams as well as by a mixture of hadrons, neutrons and gammas. The
crystals were manufactured in Bogoroditsk, Apatity (both Russia), and Shanghai
(China). These studies were carried out at the 70-GeV proton accelerator in
Protvino
Demonstration of the temporal matter-wave Talbot effect for trapped matter waves
We demonstrate the temporal Talbot effect for trapped matter waves using
ultracold atoms in an optical lattice. We investigate the phase evolution of an
array of essentially non-interacting matter waves and observe matter-wave
collapse and revival in the form of a Talbot interference pattern. By using
long expansion times, we image momentum space with sub-recoil resolution,
allowing us to observe fractional Talbot fringes up to 10th order.Comment: 17 pages, 7 figure
Kaon Production and Kaon to Pion Ratio in Au+Au Collisions at \snn=130 GeV
Mid-rapidity transverse mass spectra and multiplicity densities of charged
and neutral kaons are reported for Au+Au collisions at \snn=130 GeV at RHIC.
The spectra are exponential in transverse mass, with an inverse slope of about
280 MeV in central collisions. The multiplicity densities for these particles
scale with the negative hadron pseudo-rapidity density. The charged kaon to
pion ratios are and
for the most central collisions. The ratio is lower than the same
ratio observed at the SPS while the is higher than the SPS result.
Both ratios are enhanced by about 50% relative to p+p and +p
collision data at similar energies.Comment: 6 pages, 3 figures, 1 tabl
Azimuthal anisotropy and correlations in p+p, d+Au and Au+Au collisions at 200 GeV
We present the first measurement of directed flow () at RHIC. is
found to be consistent with zero at pseudorapidities from -1.2 to 1.2,
then rises to the level of a couple of percent over the range . The latter observation is similar to data from NA49 if the SPS rapidities
are shifted by the difference in beam rapidity between RHIC and SPS.
Back-to-back jets emitted out-of-plane are found to be suppressed more if
compared to those emitted in-plane, which is consistent with {\it jet
quenching}. Using the scalar product method, we systematically compared
azimuthal correlations from p+p, d+Au and Au+Au collisions. Flow and non-flow
from these three different collision systems are discussed.Comment: Quark Matter 2004 proceeding, 4 pages, 3 figure
- …