199 research outputs found

    Multi-imaging x-ray streak camera for ultrahigh-speed two dimensional x-ray imaging of imploded core plasmas(invited)

    Full text link
    Copyright 2004 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Review of Scientific Instruments, 75(10), 3921-3925, 2004 and may be found at http://dx.doi.org/10.1063/1.178924

    Implosion hydrodynamics of fast ignition targets

    Full text link
    Copyright 2005 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Physics of Plasmas, 12(5), 056312, 2005 and may be found at http://dx.doi.org/10.1063/1.189695

    Transport study of intense-laser-produced fast electrons in solid targets with a preplasma created by a long pulse laser

    Full text link
    Copyright 2010 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Physics of Plasmas, 17(6), 060704, 2010 and may be found at http://dx.doi.org/10.1063/1.344787

    Correlation between laser accelerated MeV proton and electron beams using simple fluid model for target normal sheath acceleration

    Full text link
    Copyright 2010 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Physics of Plasmas, 17(7), 073110, 2010 and may be found at http://dx.doi.org/10.1063/1.345906

    Review of progress in Fast Ignition

    Full text link
    Copyright 2005 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Physics of Plasmas, 12(5), 057305, 2005 and may be found at http://dx.doi.org/10.1063/1.187124

    Extragalactic neutrino background from very young pulsars surrounded by supernova envelopes

    Full text link
    We estimate the extragalactic muon neutrino background which is produced by hadrons injected by very young pulsars at an early phase after supernova explosion. It is assumed that hadrons are accelerated in the pulsar wind zone which is filled with thermal photons captured below the expanding supernova envelope. In collisions with those thermal photons hadrons produce pions which decay into muon neutrinos. At a later time, muon neutrinos are also produced by the hadrons in collisions with matter of the expanding envelope. We show that extragalactic neutrino background predicted by such a model should be detectable by the planned 1 km2^2 neutrino detector if a significant part of pulsars is born with periods shorter than 10\sim 10 ms. Since such population of pulsars is postulated by the recent models of production of extremely high energy cosmic rays, detection of neutrinos with predicted fluxes can be used as their observational test.Comment: 4 pages, 2 figures, A&A style, accepted to A&A Let

    Design, Commissioning and Performance of the PIBETA Detector at PSI

    Full text link
    We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an active segmented plastic target, a pair of low-mass cylindrical wire chambers and a 20-element cylindrical plastic scintillator hodoscope. The whole detector system is housed inside a temperature-controlled lead brick enclosure which in turn is lined with cosmic muon plastic veto counters. Commissioning and calibration data were taken during two three-month beam periods in 1999/2000 with pi+ stopping rates between 1.3*E3 pi+/s and 1.3*E6 pi+/s. We examine the timing, energy and angular detector resolution for photons, positrons and protons in the energy range of 5-150 MeV, as well as the response of the detector to cosmic muons. We illustrate the detector signatures for the assorted rare pion and muon decays and their associated backgrounds.Comment: 117 pages, 48 Postscript figures, 5 tables, Elsevier LaTeX, submitted to Nucl. Instrum. Meth.

    A diagnostic PCR assay for the detection of an Australian epidemic strain of Pseudomonas aeruginosa

    Get PDF
    Background Chronic lung infection with the bacterium Pseudomonas aeruginosa is one of the hallmarks of cystic fibrosis (CF) and is associated with worsening lung function, increased hospitalisation and reduced life expectancy. A virulent clonal strain of P. aeruginosa (Australian epidemic strain I; AES-I) has been found to be widespread in CF patients in eastern Australia. Methods Suppression subtractive hybridization (SSH) was employed to identify genetic sequences that are present in the AES-I strain but absent from the sequenced reference strain PAO1. We used PCR to evaluate the distribution of several of the AES-I loci amongst a collection of 188 P. aeruginosa isolates which was comprised of 35 AES-I isolates (as determined by PFGE), 78 non-AES-I CF isolates including other epidemic CF strains as well as 69 P. aeruginosa isolates from other clinical and environmental sources. Results We have identified a unique AES-I genetic locus that is present in all 35 AES-I isolates tested and not present in any of the other 153 P. aeruginosa strains examined. We have used this unique AES-I locus to develop a diagnostic PCR and a real-time PCR assay to detect the presence of P. aeruginosa and AES-I in patient sputum samples
    corecore