2,106 research outputs found
An integrated eddy current detection and imaging system on a silicon chip
Eddy current probes have been used for many years for numerous sensing applications including crack detection in metals. However, these applications have traditionally used the eddy current effect in the form of a physically wound single or different probe pairs which of necessity must be made quite large compared to microelectronics dimensions. Also, the traditional wound probe can only take a point reading, although that point might include tens of individual cracks or crack arrays; thus, conventional eddy current probes are beset by two major problems: (1) no detailed information can be obtained about the crack or crack array; and (2) for applications such as quality assurance, a vast amount of time must be taken to scan a complete surface. Laboratory efforts have been made to fabricate linear arrays of single turn probes in a thick film format on a ceramic substrate as well as in a flexible cable format; however, such efforts inherently suffer from relatively large size requirements as well as sensitivity issues. Preliminary efforts to fully extend eddy current probing from a point or single dimensional level to a two dimensional micro-eddy current format on a silicon chip, which might overcome all of the above problems, are presented
Recommended from our members
Live blogs, sources, and objectivity: The contradictions of real-time online reporting
Live blogs, also known as live pages or streams, allow journalists to report on events, including breaking news stories, as they happen. Their prevalence and popularity make them an important format, through which many of the developments in contemporary journalism can be observed and analysed. Using the Egyptian revolution of 2011 as a case study, we carried out a large-scale content analysis across six national UK news publishers, to analyse the differences and similarities between live blogs (n=75), traditional online news articles (n=842), and print articles (n=148). The findings reveal significant differences, for example the extent to which live blogs quote their sources directly and, also, rely on previously-published media reports as a source. The findings demonstrate how, with the expansion of real-time online reporting, journalism may be becoming more transparent yet also more reflexive; prompting, perhaps, reassessments and even redefinitions of media plurality and journalistic objectivity
Recommended from our members
Multi-line Adaptive Perimetry (MAP): A New Procedure for Quantifying Visual Field Integrity for Rapid Assessment of Macular Diseases.
PurposeIn order to monitor visual defects associated with macular degeneration (MD), we present a new psychophysical assessment called multiline adaptive perimetry (MAP) that measures visual field integrity by simultaneously estimating regions associated with perceptual distortions (metamorphopsia) and visual sensitivity loss (scotoma).MethodsWe first ran simulations of MAP with a computerized model of a human observer to determine optimal test design characteristics. In experiment 1, predictions of the model were assessed by simulating metamorphopsia with an eye-tracking device with 20 healthy vision participants. In experiment 2, eight patients (16 eyes) with macular disease completed two MAP assessments separated by about 12 weeks, while a subset (10 eyes) also completed repeated Macular Integrity Assessment (MAIA) microperimetry and Amsler grid exams.ResultsResults revealed strong repeatability of MAP and high accuracy, sensitivity, and specificity (0.89, 0.81, and 0.90, respectively) in classifying patient eyes with severe visual impairment. We also found a significant relationship in terms of the spatial patterns of performance across visual field loci derived from MAP and MAIA microperimetry. However, there was a lack of correspondence between MAP and subjective Amsler grid reports in isolating perceptually distorted regions.ConclusionsThese results highlight the validity and efficacy of MAP in producing quantitative maps of visual field disturbances, including simultaneous mapping of metamorphopsia and sensitivity impairment.Translational relevanceFuture work will be needed to assess applicability of this examination for potential early detection of MD symptoms and/or portable assessment on a home device or computer
Age, Growth, Mortality, and Reproduction of Roughtongue Bass, Pronotogrammus martinicensis (Serranidae), in the Northeastern Gulf of Mexico
The inaccessibility of outer continental shelf reefs has made it difficult to investigate the biology of Pronotogrammus martinicensis, a small sea bass known to be numerous and widely distributed in such habitat. This study takes advantage of a series of cruises in the northeastern Gulf of Mexico that collected 1,485 individuals. Fish were collected over or in the vicinity of reef habitats with hook and line, otter trawl, and rotenone. We present a preliminary validation of an otolith ageing method and report that P. martinicensis reached a maximum size of 143 mm standard length (SL), grew to about 50% of this size within their first year, and lived to a maximum age of 15 yr. Size at age data (n = 490) fitted to the von Bertalanffy growth model yielded the predictive equation: SLt = 106.3(1 - e[-0.641{t-0.646}]), where t = age in years. Gonad histology (n = 333) was examined to confirm that P. martinicensis is a protogynous, monandric hermaphrodite. We found no evidence of simultaneous hermaphroditism, which had been tentatively proposed in a previous study. Most P. martinicensis matured as females in their second year (age 1), primary oocytes developed asynchronously into secondary oocytes, and females were batch spawners. Males were postmaturational. Seminiferous tissue formed as early as age 1, but, although the rate of sex change is unknown, most fish did not function as a male until age 3 or age 4. These data provide age-based benchmarks of a common reef fish species living on the outer continental shelf of the tropical western North Atlantic Ocean
Beam instrumentation for the Tevatron Collider
The Tevatron in Collider Run II (2001-present) is operating with six times
more bunches and many times higher beam intensities and luminosities than in
Run I (1992-1995). Beam diagnostics were crucial for the machine start-up and
the never-ending luminosity upgrade campaign. We present the overall picture of
the Tevatron diagnostics development for Run II, outline machine needs for new
instrumentation, present several notable examples that led to Tevatron
performance improvements, and discuss the lessons for future colliders
Chronicles of Oklahoma
Notes and Documents section for Volume 57, Number 4, Winter 1979-80. It includes a document about the preservation ordinances enacted by Guthrie, Oklahoma City, and Hammon, an announcement about the reprint of "The Historic Preservation Movement in Oklahoma," and an introduction to Oklahoma's early military forts and posts
- …