15 research outputs found
Compact Frontend-Electronics and Bidirectional 3.3 Gbps Optical Datalink for Fast Proportional Chamber Readout
The 9600 channels of the multi-wire proportional chamber of the H1 experiment
at HERA have to be read out within 96 ns and made available to the trigger
system. The tight spatial conditions at the rear end flange require a compact
bidirectional readout electronics with minimal power consumption and dead
material.
A solution using 40 identical optical link modules, each transferring the
trigger information with a physical rate of 4 x 832 Mbps via optical fibers,
has been developed and commisioned. The analog pulses from the chamber can be
monitored and the synchronization to the global HERA clock signal is ensured.Comment: 13 pages, 10 figure
Lactobacillus plantarum 2142 prevents intestinal oxidative stress in optimized in vitro systems
Recently, there has been a growing interest to replace antibiotics’ administration with the application of probiotics. The aim of our investigations was to reveal the influence of spent culture supernatant of Lactobacillus plantarum 2142 on the response of enterocytes to oxidative stress, and the spent culture supernatant’s ability to protect them from oxidative injury. The experiments were performed on non-carcinogenic porcine epithelial cell line, IPEC-J2 isolated from a neonatal piglet and on human colon adenocarcinoma cell line, Caco-2. The cells cultured on membrane inserts were treated with millimolar hydrogen peroxide solution to provoke oxidative stress. The peroxide-triggered cell response profile was evaluated via determination of change in transepithelial electrical resistance, quantification of extent of cell death by 4’,6-diamidino-2 phenylindole (DAPI) staining and via estimation of proinflammatory cytokine, IL-8 production using ELISA technique. Non-starter lactobacilli supernatant-mediated inhibition of peroxide-triggered upregulation of IL-8 production confirmed the antiinflammatory properties of active metabolites produced by Lactobacillus plantarum 2142 in acute oxidative stress
The H1 silicon vertex detector
The design, construction and performance of the H1 silicon vertex detector is
described. It consists of two cylindrical layers of double sided, double metal
silicon sensors read out by a custom designed analog pipeline chip. The analog
signals are transmitted by optical fibers to a custom designed ADC board and
are reduced on PowerPC processors. Details of the design and construction are
given and performance figures from the first data taking periods are presented.Comment: 26 pages, 18 Figure