214 research outputs found

    Chiral Perturbation Theory in the Framework of Non-Commutative Geometry

    Full text link
    We consider the non-commutative generalization of the chiral perturbation theory. The resultant coupling constants are severely restricted by the model and in good agreement with the data. When applied to the Skyrme model, our scheme reproduces the non-Skyrme term with the right coefficient. We comment on a similar treatment of the linear σ\sigma -model.Comment: In this revised manuscript, we alter one of the conclusion

    Non-Commutative Geometry and Chiral Perturbation Lagrangian

    Get PDF
    Chiral perturbation lagrangian in the framework of non-commutative geometry is considered in full detail. It is found that the explicit symmetry breaking terms appear and some relations between the coupling constants of the theory come out naturally. The WZW term also turns up on the same footing as the other terms of the chiral lagrangian.Comment: Latex, 9 page

    Smoking among male medical sciences students in Semnan, Islamic Republic of Iran

    Get PDF
    publishedVersio

    Machine Learning for Determining Interactions between Air Pollutants and Environmental Parameters in Three Cities of Iran

    Get PDF
    Air pollution, as one of the most significant environmental challenges, has adversely affected the global economy, human health, and ecosystems. Consequently, comprehensive research is being conducted to provide solutions to air quality management. Recently, it has been demonstrated that environmental parameters, including temperature, relative humidity, wind speed, air pressure, and vegetation, interact with air pollutants, such as particulate matter (PM), NO2, SO2, O3, and CO, contributing to frameworks for forecasting air quality. The objective of the present study is to explore these interactions in three Iranian metropolises of Tehran, Tabriz, and Shiraz from 2015 to 2019 and develop a machine learning-based model to predict daily air pollution. Three distinct assessment criteria were used to assess the proposed XGBoost model, including R squared (R2), Root Mean Squared Error (RMSE), and Mean Absolute Error (MAE). Preliminary results showed that although air pollutants were significantly associated with meteorological factors and vegetation, the formulated model had low accuracy in predicting (R2PM2.5 = 0.36, R2PM10 = 0.27, R2NO2 = 0.46, R2SO2 = 0.41, R2O3 = 0.52, and R2CO = 0.38). Accordingly, future studies should consider more variables, including emission data from manufactories and traffic, as well as sunlight and wind direction. It is also suggested that strategies be applied to minimize the lack of observational data by considering second-and third-order interactions between parameters, increasing the number of simultaneous air pollution and meteorological monitoring stations, as well as hybrid machine learning models based on proximal and satellite data

    Loop expansion in Yang-Mills thermodynamics

    Get PDF
    We argue that a selfconsistent spatial coarse-graining, which involves interacting (anti)calorons of unit topological charge modulus, implies that real-time loop expansions of thermodynamical quantities in the deconfining phase of SU(2) and SU(3) Yang-Mills thermodynamics are, modulo 1PI resummations, determined by a finite number of connected bubble diagrams.Comment: 15 pages, 2 figures, v5: discussion of much more severely constrained nonplanar situation included in Sec.

    A Fibreoptic Endoscopic Study of Upper Gastrointestinal Bleeding at Bugando Medical Centre in Northwestern Tanzania: a Retrospective Review of 240 Cases.

    Get PDF
    Upper gastrointestinal (GI) bleeding is recognized as a common and potentially life-threatening abdominal emergency that needs a prompt assessment and aggressive emergency treatment. A retrospective study was undertaken at Bugando Medical Centre in northwestern Tanzania between March 2010 and September 2011 to describe our own experiences with fibreoptic upper GI endoscopy in the management of patients with upper gastrointestinal bleeding in our setting and compare our results with those from other centers in the world. A total of 240 patients representing 18.7% of all patients (i.e. 1292) who had fibreoptic upper GI endoscopy during the study period were studied. Males outnumbered female by a ratio of 2.1:1. Their median age was 37 years and most of patients (60.0%) were aged 40 years and below. The vast majority of the patients (80.4%) presented with haematemesis alone followed by malaena alone in 9.2% of cases. The use of non-steroidal anti-inflammatory drugs, alcohol and smoking prior to the onset of bleeding was recorded in 7.9%, 51.7% and 38.3% of cases respectively. Previous history of peptic ulcer disease was reported in 22(9.2%) patients. Nine (3.8%) patients were HIV positive. The source of bleeding was accurately identified in 97.7% of patients. Diagnostic accuracy was greater within the first 24 h of the bleeding onset, and in the presence of haematemesis. Oesophageal varices were the most frequent cause of upper GI bleeding (51.3%) followed by peptic ulcers in 25.0% of cases. The majority of patients (60.8%) were treated conservatively. Endoscopic and surgical treatments were performed in 30.8% and 5.8% of cases respectively. 140 (58.3%) patients received blood transfusion. The median length of hospitalization was 8 days and it was significantly longer in patients who underwent surgical treatment and those with higher Rockall scores (P < 0.001). Rebleeding was reported in 3.3% of the patients. The overall mortality rate of 11.7% was significantly higher in patients with variceal bleeding, shock, hepatic decompensation, HIV infection, comorbidities, malignancy, age > 60 years and in patients with higher Rockall scores and those who underwent surgery (P < 0.001). Oesophageal varices are the commonest cause of upper gastrointestinal bleeding in our environment and it is associated with high morbidity and mortality. The diagnostic accuracy of fibreoptic endoscopy was related to the time interval between the onset of bleeding and endoscopy. Therefore, it is recommended that early endoscopy should be performed within 24 h of the onset of bleeding
    corecore