381 research outputs found

    Conservation and divergence of myelin proteome and oligodendrocyte transcriptome profiles between humans and mice

    Get PDF
    Human myelin disorders are commonly studied in mouse models. Since both clades evolutionarily diverged approximately 85 million years ago, it is critical to know to what extent the myelin protein composition has remained similar. Here, we use quantitative proteomics to analyze myelin purified from human white matter and find that the relative abundance of the structural myelin proteins PLP, MBP, CNP, and SEPTIN8 correlates well with that in C57Bl/6N mice. Conversely, multiple other proteins were identified exclusively or predominantly in human or mouse myelin. This is exemplified by peripheral myelin protein 2 (PMP2), which was specific to human central nervous system myelin, while tetraspanin-2 (TSPAN2) and connexin-29 (CX29/GJC3) were confined to mouse myelin. Assessing published scRNA-seq-datasets, human and mouse oligodendrocytes display well-correlating transcriptome profiles but divergent expression of distinct genes, including Pmp2, Tspan2, and Gjc3. A searchable web interface is accessible via www.mpinat.mpg.de/myelin. Species-dependent diversity of oligodendroglial mRNA expression and myelin protein composition can be informative when translating from mouse models to humans

    Tourist Shoppers’ Evaluation of Retail Service: A Study of Cross-Border versus International Outshoppers

    Get PDF
    This article extends the concept of customer perceived value (CPV) to the tourist outshopping context and explores the differences in antecedents and outcomes of CPV between cross-border and international outshoppers. A large-scale field survey in Hong Kong with cross-border outshoppers from mainland China and international shoppers from four Western countries (Australia, Canada, the United Kingdom, and the United States) shows that perceived product quality, risk, and value for money have a stronger effect on CPV for cross-border outshoppers, and employee service quality and lifestyle congruence for international outshoppers. CPV also has a stronger positive effect on satisfaction, word of mouth, and repeat purchase intentions for cross-border outshoppers, whereas satisfaction has a stronger positive impact on word of mouth and repeat purchase intentions for international outshoppers. We discuss the conceptual contribution and managerial implications of our findings for international retailers, researchers, and tourism organizations

    Simultaneous X-Ray and TeV Gamma-Ray Observations of the TeV Blazar Markarian 421 during February and May 2000

    Full text link
    In this paper we present the results of simultaneous observations of the TeV blazar Markarian 421 (Mrk 421) at X-ray and TeV Gamma-ray energies with the Rossi X-Ray Timing Explorer (RXTE) and the stereoscopic Cherenkov Telescope system of the HEGRA (High Energy Gamma Ray Astronomy) experiment, respectively. The source was monitored from February 2nd to February 16th and from May 3rd to May 8th, 2000. We discuss in detail the temporal and spectral properties of the source. Remarkably, the TeV observations of February 7th/8th showed statistically significant evidence for substantial TeV flux variability on 30 min time scale. We show the results of modeling the data with a time dependent homogeneous Synchrotron Self-Compton (SSC) model. The X-ray and TeV gamma-ray emission strengths and energy spectra together with the rapid flux variability strongly suggest that the emission volume is approaching the observer with a Doppler factor of 50 or higher. The different flux variability time scales observed at X-rays and TeV Gamma-rays indicate that a more detailed analysis will require inhomogeneous models with several emission zones.Comment: Accepted for Publication in ApJ, 21 Pages, 5 Figure

    Rejection of the hypothesis that Markarian 501 TeV photons are pure Bose-Einstein condensates

    Full text link
    The energy spectrum of the Blazar type galaxy Markarian 501 (Mrk 501) as measured by the High-Energy-Gamma-Ray Astronomy (HEGRA) air Cerenkov telescopes extends beyond 16 TeV and constitutes the most energetic photons observed from an extragalactic object. A fraction of the emitted spectrum is possibly absorbed in interactions with low energy photons of the diffuse extragalactic infrared radiation, which in turn offers the unique possibility to measure the diffuse infrared radiation density by TeV spectroscopy. The upper limit on the density of the extragalactic infrared radiation derived from the TeV observations imposes constraints on models of galaxy formation and stellar evolution. One of the recently published ideas to overcome severe absorption of TeV photons is based upon the assumption that sources like Mrk 501 could produce Bose-Einstein condensates of coherent photons. The condensates would have a higher survival probability during the transport in the diffuse radiation field and could mimic TeV air shower events. The powerful stereoscopic technique of the HEGRA air Cerenkov telescopes allows to test this hypothesis by reconstructing the penetration depths of TeV air shower events: Air showers initiated by Bose-Einstein condensates are expected to reach the maximum of the shower development in the atmosphere earlier than single photon events. By comparing the energy-dependent penetration depths of TeV photons from Mrk 501 with those from the TeV standard-candle Crab Nebula and simulated air shower events, we can reject the hypothesis that TeV photons from Mrk 501 are pure Bose-Einstein condensates.Comment: 9 pages, 2 figures, published by ApJ Letters, revised version (simulation results added

    Transition Rates between Mixed Symmetry States: First Measurement in 94Mo

    Full text link
    The nucleus 94Mo was investigated using a powerful combination of gamma-singles photon scattering experiments and gamma-gamma-coincidence studies following the beta-decay of 94mTc. The data survey short-lived J^pi=1+,2+ states and include branching ratios, E2/M1 mixing ratios, lifetimes, and transition strengths. The mixed-symmetry (MS) 1+ scissors mode and the 2+ MS state are identified from M1 strengths. A gamma transition between MS states was observed and its rate was measured. Nine M1 and E2 strengths involving MS states agree with the O(6) limit of the interacting boson model-2 using the proton boson E2 charge as the only free parameter.Comment: 9 pages, 3 PostScript figures included, ReVTeX, accepted for publication in Physical Review Letters, tentatively scheduled for August 9, 199

    The unidentified TeV source (TeVJ2032+4130) and surrounding field: Final HEGRA IACT-System results

    Get PDF
    The unidentified TeV source in Cygnus is now confirmed by follow-up observations from 2002 with the HEGRA stereoscopic system of Cherenkov Telescopes. Using all data (1999 to 2002) we confirm this new source as steady in flux over the four years of data taking, extended with radius 6.2 arcmin (+-1.2 arcmin (stat) +-0.9 arcmin (sys)) and exhibiting a hard spectrum with photon index -1.9. It is located in the direction of the dense OB stellar association, Cygnus OB2. Its integral flux above energies E>1 TeV amounts to \~5% of the Crab assuming a Gaussian profile for the intrinsic source morphology. There is no obvious counterpart at radio, optical nor X-ray energies, leaving TeVJ2032+4130 presently unidentified. Observational parameters of this source are updated here and some astrophysical discussion is provided. Also included are upper limits for a number of other interesting sources in the FoV, including the famous microquasar Cygnus X-3.Comment: 7 pages, 3 figures. Accepted for publication in Astronomy & Astrophysic

    The TeV Energy Spectrum of Mkn 501 Measured with the Stereoscopic Telescope System of HEGRA during 1998 and 1999

    Full text link
    During 1997, the BL Lac object Mkn 501 went into an extraordinary state of high X-ray and TeV gamma-ray activity, lasting more than 6 months. In this paper we report on the TeV emission characteristics of the source in the subsequent years of 1998 and 1999 as measured with the Stereoscopic Cherenkov Telescope System of HEGRA (La Palma, Canary Islands). Our observations reveal a 1998-1999 mean emission level at 1 TeV of 1/3 of the flux of the Crab Nebula, a factor of 10 lower than during the year of 1997. A dataset of 122 observations hours with the HEGRA telescope system makes it possible to assess for the first time the Mkn 501 TeV energy spectrum for a mean flux level substantially below that of the Crab Nebula with reasonable statistical accuracy. Excluding the data of a strong flare, we find evidence that the 1998--1999 low-flux spectrum is substantially softer (by 0.44+-0.1(stat) in spectral index) than the 1997 time averaged spectrum. The 500 GeV to 10 TeV energy spectrum can well be described by a power law model with exponential cutoff: dN/dE ~ E^(-alpha) exp(-E/E0) with alpha=2.31+-0.22(stat), and E0=5.1 (-2.3+7.8)(stat) TeV. Within statistical accuracy, also a pure power law model gives an acceptable fit to the data: dN/dE ~ E^(-Gamma) with Gamma=2.76+-0.08(stat). After presenting the 1998-1999 TeV characteristics of the source we discuss the implications of the results.Comment: Accepted for publication in The Astrophysical Journal, Part 1, on August 4th, 200

    Evidence for TeV gamma ray emission from Cassiopeia A

    Get PDF
    232 hours of data were accumulated from 1997 to 1999, using the HEGRA Stereoscopic Cherenkov Telescope System to observe the supernova remnant Cassiopeia A. TeV gamma ray emission was detected at the 5 sigma level, and a flux of (5.8 +- 1.2(stat) +- 1.2(syst)) 10^(-9) ph m^(-2) s^(-1) above 1 TeV was derived. The spectral distribution is consistent with a power law with a differential spectral index of -2.5 +- 0.4(stat) +- 0.1(syst) between 1 and 10 TeV. As this is the first report of the detection of a TeV gamma ray source on the "centi-Crab" scale, we present the analysis in some detail. Implications for the acceleration of cosmic rays depend on the details of the source modeling. We discuss some important aspects in this paper.Comment: 9 pages, 6 figures, accepted for publication in Astronomy & Astrophysic

    Is the giant radio galaxy M 87 a TeV gamma-ray emitter?

    Get PDF
    For the first time an excess of photons above an energy threshold of 730 GeV from the giant radio galaxy M 87 has been measured at a significance level above 4 σ. The data have been taken during the years 1998 and 1999 with the HEGRA stereoscopic system of 5 imaging atmospheric Cherenkov telescopes. The excess of 107.4 ± 26.8 events above 730 GeV corresponds to an integral flux of 3.3% of the Crab flux or Nγ (E > 730 GeV) = (0.96 ± 0.23) × 10-12 phot cm-2 s-1. M 87 is located at the center of the Virgo cluster of galaxies at a relatively small redshift of z = 0.00436 and is a promising candidate among the class of giant radio galaxies for the emission of TeV γ-radiation. The detection of TeV γ-rays from M 87 - if confirmed - would establish a new class of extragalactic source in this energy regime since all other AGN detected to date at TeV energies are BL Lac type objects.F. A. Aharonian ...G. P. Rowell...et al
    corecore