381 research outputs found
Conservation and divergence of myelin proteome and oligodendrocyte transcriptome profiles between humans and mice
Human myelin disorders are commonly studied in mouse models. Since both clades evolutionarily diverged approximately 85 million years ago, it is critical to know to what extent the myelin protein composition has remained similar. Here, we use quantitative proteomics to analyze myelin purified from human white matter and find that the relative abundance of the structural myelin proteins PLP, MBP, CNP, and SEPTIN8 correlates well with that in C57Bl/6N mice. Conversely, multiple other proteins were identified exclusively or predominantly in human or mouse myelin. This is exemplified by peripheral myelin protein 2 (PMP2), which was specific to human central nervous system myelin, while tetraspanin-2 (TSPAN2) and connexin-29 (CX29/GJC3) were confined to mouse myelin. Assessing published scRNA-seq-datasets, human and mouse oligodendrocytes display well-correlating transcriptome profiles but divergent expression of distinct genes, including Pmp2, Tspan2, and Gjc3. A searchable web interface is accessible via www.mpinat.mpg.de/myelin. Species-dependent diversity of oligodendroglial mRNA expression and myelin protein composition can be informative when translating from mouse models to humans
Disappearing Paradigms in Shareholder Protection: Leximetric Evidence for 30 Countries, 1990-2013
Tourist Shoppers’ Evaluation of Retail Service: A Study of Cross-Border versus International Outshoppers
This article extends the concept of customer perceived value (CPV) to the tourist outshopping context and explores the differences in antecedents and outcomes of CPV between cross-border and international outshoppers. A large-scale field survey in Hong Kong with cross-border outshoppers from mainland China and international shoppers from four Western countries (Australia, Canada, the United Kingdom, and the United States) shows that perceived product quality, risk, and value for money have a stronger effect on CPV for cross-border outshoppers, and employee service quality and lifestyle congruence for international outshoppers. CPV also has a stronger positive effect on satisfaction, word of mouth, and repeat purchase intentions for cross-border outshoppers, whereas satisfaction has a stronger positive impact on word of mouth and repeat purchase intentions for international outshoppers. We discuss the conceptual contribution and managerial implications of our findings for international retailers, researchers, and tourism organizations
Simultaneous X-Ray and TeV Gamma-Ray Observations of the TeV Blazar Markarian 421 during February and May 2000
In this paper we present the results of simultaneous observations of the TeV
blazar Markarian 421 (Mrk 421) at X-ray and TeV Gamma-ray energies with the
Rossi X-Ray Timing Explorer (RXTE) and the stereoscopic Cherenkov Telescope
system of the HEGRA (High Energy Gamma Ray Astronomy) experiment, respectively.
The source was monitored from February 2nd to February 16th and from May 3rd to
May 8th, 2000. We discuss in detail the temporal and spectral properties of the
source. Remarkably, the TeV observations of February 7th/8th showed
statistically significant evidence for substantial TeV flux variability on 30
min time scale. We show the results of modeling the data with a time dependent
homogeneous Synchrotron Self-Compton (SSC) model. The X-ray and TeV gamma-ray
emission strengths and energy spectra together with the rapid flux variability
strongly suggest that the emission volume is approaching the observer with a
Doppler factor of 50 or higher. The different flux variability time scales
observed at X-rays and TeV Gamma-rays indicate that a more detailed analysis
will require inhomogeneous models with several emission zones.Comment: Accepted for Publication in ApJ, 21 Pages, 5 Figure
Rejection of the hypothesis that Markarian 501 TeV photons are pure Bose-Einstein condensates
The energy spectrum of the Blazar type galaxy Markarian 501 (Mrk 501) as
measured by the High-Energy-Gamma-Ray Astronomy (HEGRA) air Cerenkov telescopes
extends beyond 16 TeV and constitutes the most energetic photons observed from
an extragalactic object. A fraction of the emitted spectrum is possibly
absorbed in interactions with low energy photons of the diffuse extragalactic
infrared radiation, which in turn offers the unique possibility to measure the
diffuse infrared radiation density by TeV spectroscopy. The upper limit on the
density of the extragalactic infrared radiation derived from the TeV
observations imposes constraints on models of galaxy formation and stellar
evolution. One of the recently published ideas to overcome severe absorption of
TeV photons is based upon the assumption that sources like Mrk 501 could
produce Bose-Einstein condensates of coherent photons. The condensates would
have a higher survival probability during the transport in the diffuse
radiation field and could mimic TeV air shower events. The powerful
stereoscopic technique of the HEGRA air Cerenkov telescopes allows to test this
hypothesis by reconstructing the penetration depths of TeV air shower events:
Air showers initiated by Bose-Einstein condensates are expected to reach the
maximum of the shower development in the atmosphere earlier than single photon
events. By comparing the energy-dependent penetration depths of TeV photons
from Mrk 501 with those from the TeV standard-candle Crab Nebula and simulated
air shower events, we can reject the hypothesis that TeV photons from Mrk 501
are pure Bose-Einstein condensates.Comment: 9 pages, 2 figures, published by ApJ Letters, revised version
(simulation results added
Transition Rates between Mixed Symmetry States: First Measurement in 94Mo
The nucleus 94Mo was investigated using a powerful combination of
gamma-singles photon scattering experiments and gamma-gamma-coincidence studies
following the beta-decay of 94mTc. The data survey short-lived J^pi=1+,2+
states and include branching ratios, E2/M1 mixing ratios, lifetimes, and
transition strengths. The mixed-symmetry (MS) 1+ scissors mode and the 2+ MS
state are identified from M1 strengths. A gamma transition between MS states
was observed and its rate was measured. Nine M1 and E2 strengths involving MS
states agree with the O(6) limit of the interacting boson model-2 using the
proton boson E2 charge as the only free parameter.Comment: 9 pages, 3 PostScript figures included, ReVTeX, accepted for
publication in Physical Review Letters, tentatively scheduled for August 9,
199
The unidentified TeV source (TeVJ2032+4130) and surrounding field: Final HEGRA IACT-System results
The unidentified TeV source in Cygnus is now confirmed by follow-up
observations from 2002 with the HEGRA stereoscopic system of Cherenkov
Telescopes. Using all data (1999 to 2002) we confirm this new source as steady
in flux over the four years of data taking, extended with radius 6.2 arcmin
(+-1.2 arcmin (stat) +-0.9 arcmin (sys)) and exhibiting a hard spectrum with
photon index -1.9. It is located in the direction of the dense OB stellar
association, Cygnus OB2. Its integral flux above energies E>1 TeV amounts to
\~5% of the Crab assuming a Gaussian profile for the intrinsic source
morphology. There is no obvious counterpart at radio, optical nor X-ray
energies, leaving TeVJ2032+4130 presently unidentified. Observational
parameters of this source are updated here and some astrophysical discussion is
provided. Also included are upper limits for a number of other interesting
sources in the FoV, including the famous microquasar Cygnus X-3.Comment: 7 pages, 3 figures. Accepted for publication in Astronomy &
Astrophysic
The TeV Energy Spectrum of Mkn 501 Measured with the Stereoscopic Telescope System of HEGRA during 1998 and 1999
During 1997, the BL Lac object Mkn 501 went into an extraordinary state of
high X-ray and TeV gamma-ray activity, lasting more than 6 months. In this
paper we report on the TeV emission characteristics of the source in the
subsequent years of 1998 and 1999 as measured with the Stereoscopic Cherenkov
Telescope System of HEGRA (La Palma, Canary Islands). Our observations reveal a
1998-1999 mean emission level at 1 TeV of 1/3 of the flux of the Crab Nebula, a
factor of 10 lower than during the year of 1997. A dataset of 122 observations
hours with the HEGRA telescope system makes it possible to assess for the first
time the Mkn 501 TeV energy spectrum for a mean flux level substantially below
that of the Crab Nebula with reasonable statistical accuracy. Excluding the
data of a strong flare, we find evidence that the 1998--1999 low-flux spectrum
is substantially softer (by 0.44+-0.1(stat) in spectral index) than the 1997
time averaged spectrum. The 500 GeV to 10 TeV energy spectrum can well be
described by a power law model with exponential cutoff: dN/dE ~ E^(-alpha)
exp(-E/E0) with alpha=2.31+-0.22(stat), and E0=5.1 (-2.3+7.8)(stat) TeV. Within
statistical accuracy, also a pure power law model gives an acceptable fit to
the data: dN/dE ~ E^(-Gamma) with Gamma=2.76+-0.08(stat). After presenting the
1998-1999 TeV characteristics of the source we discuss the implications of the
results.Comment: Accepted for publication in The Astrophysical Journal, Part 1, on
August 4th, 200
Evidence for TeV gamma ray emission from Cassiopeia A
232 hours of data were accumulated from 1997 to 1999, using the HEGRA
Stereoscopic Cherenkov Telescope System to observe the supernova remnant
Cassiopeia A. TeV gamma ray emission was detected at the 5 sigma level, and a
flux of (5.8 +- 1.2(stat) +- 1.2(syst)) 10^(-9) ph m^(-2) s^(-1) above 1 TeV
was derived. The spectral distribution is consistent with a power law with a
differential spectral index of -2.5 +- 0.4(stat) +- 0.1(syst) between 1 and 10
TeV. As this is the first report of the detection of a TeV gamma ray source on
the "centi-Crab" scale, we present the analysis in some detail. Implications
for the acceleration of cosmic rays depend on the details of the source
modeling. We discuss some important aspects in this paper.Comment: 9 pages, 6 figures, accepted for publication in Astronomy &
Astrophysic
Is the giant radio galaxy M 87 a TeV gamma-ray emitter?
For the first time an excess of photons above an energy threshold of 730 GeV from the giant radio galaxy M 87 has been measured at a significance level above 4 σ. The data have been taken during the years 1998 and 1999 with the HEGRA stereoscopic system of 5 imaging atmospheric Cherenkov telescopes. The excess of 107.4 ± 26.8 events above 730 GeV corresponds to an integral flux of 3.3% of the Crab flux or Nγ (E > 730 GeV) = (0.96 ± 0.23) × 10-12 phot cm-2 s-1. M 87 is located at the center of the Virgo cluster of galaxies at a relatively small redshift of z = 0.00436 and is a promising candidate among the class of giant radio galaxies for the emission of TeV γ-radiation. The detection of TeV γ-rays from M 87 - if confirmed - would establish a new class of extragalactic source in this energy regime since all other AGN detected to date at TeV energies are BL Lac type objects.F. A. Aharonian ...G. P. Rowell...et al
- …