4,581 research outputs found

    Narrow Technihadron Production at the First Muon Collider

    Get PDF
    In modern technicolor models, there exist very narrow spin-zero and spin-one neutral technihadrons---piT0pi^0_T, rhoT0rho^0_T and omegaTomega_T---with masses of a few 100 GeV. The large coupling of πT0\pi^0_T to μ+μ\mu^+\mu^-, the direct coupling of rhoT0rho^0_T and omegaTomega_T to the photon and Z0Z^0, and the superb energy resolution of the First Muon Collider may make it possible to resolve these technihadrons and produce them at extraordinarily large rates.Comment: 11 pages, latex, including 2 postscript figure

    Balance Functions, Correlations, Charge Fluctuations and Interferometry

    Get PDF
    Connections between charge balance functions, charge fluctuations and correlations are presented. It is shown that charge fluctuations can be directly expressed in terms of a balance functions under certain assumptions. The distortion of charge balance functions due to experimental acceptance is discussed and the effects of identical boson interference is illustrated with a simple model.Comment: 1 eps figure included. 5 pages in revtex

    A practice-related risk score (PRS): a DOPPS-derived aggregate quality index for haemodialysis facilities

    Get PDF
    Background. The Dialysis Outcomes and Practice Patterns Study (DOPPS) database was used to develop and validate a practice-related risk score (PRS) based on modifiable practices to help facilities assess potential areas for improving patient care. Methods. Relative risks (RRs) from a multivariable Cox mortality model, based on observational haemodialysis (HD) patient data from DOPPS I (1996-2001, seven countries), were used. The four practices were the percent of patients with Kt/V >= 1.2, haemoglobin >= 11 g/dl (110 g/l), albumin >= 4.0 g/dl (40g/l) and catheter use, and were significantly related to mortality when modelled together. DOPPS II data (2002-2004, 12 countries) were used to evaluate the relationship between PRS and mortality risk using Cox regression. Results. For facilities in DOPPS I and II, changes in PRS over time were significantly correlated with changes in the standardized mortality ratio (SMR). The PRS ranged from 1.0 to 2.1. Overall, the adjusted RR of death was 1.05 per 0.1 points higher PRS (P < 0.0001). For facilities in both DOPPS I and II (N = 119), a 0.2 decrease in PRS was associated with a 0.19 decrease in SMR (P = 0.005). On average, facilities that improved PRS practices showed significantly reduced mortality over the same time frame. Conclusions. The PRS assesses modifiable HD practices that are linked to improved patient survival. Further refinements might lead to improvements in the PRS and will address regional variations in the PRS/mortality relationship

    Vacuum Alignment in Technicolor Theories-I. The Technifermion Sector

    Get PDF
    We have carried out numerical studies of vacuum alignment in technicolor models of electroweak and flavor symmetry breaking. The goal is to understand alignment's implications for strong and weak CP nonconservation in quark interactions. In this first part, we restrict our attention to the technifermion sector of simple models. We find several interesting phenomena, including (1) the possibility that all observable phases in the technifermions' unitary vacuum-alignment matrix are integer multiples of \pi/N' where N' \le N, the number of technifermion doublets, and (2) the possibility of exceptionally light pseudoGoldstone technipions.Comment: 19 pages, Latex with one postscript figur

    Lubiprostone Stimulates Duodenal Bicarbonate Secretion in Rats

    Get PDF
    Lubiprostone, a bicyclic fatty acid, is used for the treatment of chronic constipation. No published study has addressed the effect of lubiprostone on intestinal ion secretion in vivo. The aim of this study was to test the hypothesis that lubiprostone augments duodenal HCO3 − secretion (DBS). Rat proximal duodenal loops were perfused with pH 7.0 Krebs, control vehicle (medium-chain triglycerides), or lubiprostone (0.1–10 μM). We measured DBS with flow-through pH and CO2 electrodes, perfusate [Cl−] with a Cl− electrode, and water flux using a non-absorbable ferrocyanide marker. Some rats were pretreated with a potent, selective CFTR antagonist, CFTRinh-172 (1 mg/kg, ip), 1 h before experiments. Perfusion of lubiprostone concentration dependently increased DBS, whereas net Cl− output and net water output were only increased at 0.1 μM, compared with vehicle. CFTRinh-172 reduced lubiprostone (10 μM)-induced DBS increase, whereas net Cl− output was also unchanged. Nevertheless, CFTRinh-172 reduced basal net water output, which was reversed by lubiprostone. Furthermore, lubiprostone-induced DBS was inhibited by EP4 receptor antagonist, not by an EP1/2 receptor antagonist or by indomethacin pretreatment. In this first study of the effect of lubiprostone on intestinal ion secretion in vivo, lubiprostone stimulated CFTR-dependent DBS without changing net Cl− secretion. This effect supports the hypothesis that Cl− secreted by CFTR is recycled across the apical membrane by anion exchangers. Recovery of water output during CFTR inhibition suggests that lubiprostone may improve the intestinal phenotype in CF patients. Furthermore, increased DBS suggests that lubiprostone may protect the duodenum from acid-induced injury via EP4 receptor activation

    On Axially Symmetric Solutions in the Electroweak Theory

    Full text link
    We present the general ansatz, the energy density and the Chern-Simons charge for static axially symmetric configurations in the bosonic sector of the electroweak theory. Containing the sphaleron, the multisphalerons and the sphaleron-antisphaleron pair at finite mixing angle, the ansatz further allows the construction of the sphaleron and multisphaleron barriers and of the bisphalerons at finite mixing angle. We conjecture that further solutions exist.Comment: 17 pages, latex, THU-94/0

    Status and overview of development of the Silicon Pixel Detector for the PHENIX experiment at the BNL RHIC

    Get PDF
    We have developed a silicon pixel detector to enhance the physics capabilities of the PHENIX experiment. This detector, consisting of two layers of sensors, will be installed around the beam pipe at the collision point and covers a pseudo-rapidity of | \eta | < 1.2 and an azimuth angle of | \phi | ~ 2{\pi}. The detector uses 200 um thick silicon sensors and readout chips developed for the ALICE experiment. In order to meet the PHENIX DAQ readout requirements, it is necessary to read out 4 readout chips in parallel. The physics goals of PHENIX require that radiation thickness of the detector be minimized. To meet these criteria, the detector has been designed and developed. In this paper, we report the current status of the development, especially the development of the low-mass readout bus and the front-end readout electronics.Comment: 9 pages, 8 figures and 1 table in DOCX (Word 2007); PIXEL 2008 workshop proceedings, will be published in the Proceedings Section of JINST(Journal of Instrumentation

    Characterisation of Medipix3 Silicon Detectors in a Charged-Particle Beam

    Get PDF
    While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and shown to be in agreement with simulation, demonstrating the suitability of the Medipix3 ASIC as a tool for characterising pixel sensors.Comment: 16 pages, 13 figure

    Exact Baryon, Strangeness and Charge Conservation in Hadronic Gas Models

    Get PDF
    Relativistic heavy ion collisions are studied assuming that particles can be described by a hadron gas in thermal and chemical equilibrium. The exact conservation of baryon number, strangeness and charge are explicitly taken into account. For heavy ions the effect arising from the neutron surplus becomes important and leads to a substantial increase in e.g. the π/π+\pi^-/\pi^+ ratio. A method is developed which is very well suited for the study of small systems.Comment: 5 pages, 5 Postscript figure

    Resonant and Non-Resonant Effects in Photon-Technipion Production at Lepton Colliders

    Get PDF
    Lepton collider experiments can search for light technipions in final states made striking by the presence of an energetic photon: e+e- \to \photon\technipion. To date, searches have focused on either production through anomalous coupling of the technipions to electroweak gauge bosons or on production through a technivector meson (\technirho, \techniomega) resonance. This paper creates a combined framework in which both contributions are included. This will allow stronger and more accurate limits on technipion production to be set using existing data from LEP or future data from a higher-energy linear collider. We provide explicit formulas and sample calculations (analytic and Pythia) in the framework of the Technicolor Straw Man Model, a model that includes light technihadrons.Comment: 11 pages, including title page, 3 figures; version 2: references adde
    corecore