16 research outputs found
Surface modification of PVC endotracheal tubes by oxygen glow discharge to reduce bacterial adhesion
A d.c. oxygen glow discharge was used to modify medical-grade poly(vinyl chloride) (PVC) to study how surface chemistry and hydrophilicity influence Pseudomonas aeruginosa adhesion. The effects of plasma exposure time on the resulting surface, including chemical composition, wettability and roughness, were assessed using x-ray photoelectron spectroscopy, contact angle measurements and atomic force microscopy analysis. A significant alteration in the hydrophilicity of the native PVC surface was observed after oxygen glow discharge treatment. The water contact angle decreased from similar to80degrees to 8-20degrees, with a weak dependence of the exposure time used. The change in surface wettability resulted from the incorporation of oxygenated functional groups, including esters, ketones and acids, as indicated by XPS analysis. The amount of oxygen incorporation was shown to be essentially independent of plasma exposure time. However, prolonged plasma exposure resulted in increased surface roughness. Bacterial adhesion efficiency was evaluated for PVC modified by 120 s of plasma exposure, because this exposure time was determined to yield the maximum decrease in contact angle. Oxygen plasma treatment of native PVC was found to yield a 70% reduction in bacterial adhesion for the four strains of Pseudomonas aeruginosa tested. Copyright (C) 2003 John Wiley Sons, Ltd
Inhibition of bacterial adhesion on PVC endotracheal tubes by RF-oxygen glow discharge, sodium hydroxide and silver nitrate treatments
Medical-grade poly(vinyl chloride) (PVC) was chemically modified to study how the incorporation of monovalent silver influences Pseudomonas aeruginosa adhesion and colonization. The modification investigated consisted of a radio frequency-oxygen (RF-O-2) glow discharge pre-functionalization, followed by a two-step wet-treatment in sodium hydroxide and silver nitrate solutions. X-ray photoelectron spectroscopy (XPS) analysis and contact angle measurements were used to investigate the chemical nature and surface wettability of the films following each step of the modification. XPS analysis proved that the RF-O-2 plasma pre-functionalization of native PVC reproducibly increased the amount of functional groups representative of PVC additives, including ether/alcohol, esters and carboxyl groups. More specifically, we demonstrated that the O-C-O groups representative of the phthalic ester and zinc carboxylate additives identified for native PVC increased by two-fold following the RF-O-2 plasma pre-functionalization step. Although RF-O-2 pre-functionalization did not have an effect on the silver content of the NaOH/AgNO3 treated substrates, such a modification was necessary for biomaterial products that did not have reproducible surfaces amongst production lots. XPS analysis also demonstrated that saponification with sodium hydroxide (NaOH) of esters, like those of the phthalic ester additives of PVC is a simple, irreversible method of hydrolysis, which produced sodium carboxylate and sodium phthalate salts. Exposure of native PVC to NaOH resulted in an increased surface hydrophilicity (from ca 90degrees to ca 60degrees) due to dechlorination. XPS analysis following further incubation in silver nitrate demonstrated that silver ions can be trapped when the sodium of sodium carboxylate is replaced by silver after performing a second treatment with a monovalent silver-containing solution. The creation of silver salt on native PVC resulted in an ultra-hydrophobic (> 120degrees) surface. The chemical modifications using NaOH and AgNO3 wet treatments completely inhibited bacterial adhesion of four strains of P. aeruginosa to both native and oxygen-pre-functionalized PVC, and efficiently prevented colonization over longer periods (72 h). Our results suggest that surface modifications that incorporate silver ions would be extremely effective at reducing bacterial colonization to medical devices. (C) 2003 Elsevier Ltd. All rights reserved
Inhibition of bacterial adhesion on PVC endotracheal tubes by RF-oxygen glow discharge, sodium hydroxide and silver nitrate treatments
Medical-grade poly(vinyl chloride) (PVC) was chemically modified to study how the incorporation of monovalent silver influences Pseudomonas aeruginosa adhesion and colonization. The modification investigated consisted of a radio frequency-oxygen (RF-O(2)) glow discharge pre-functionalization, followed by a two-step wet-treatment in sodium hydroxide and silver nitrate solutions. X-ray photoelectron spectroscopy (XPS) analysis and contact angle measurements were used to investigate the chemical nature and surface wettability of the films following each step of the modification. XPS analysis proved that the RF-O(2) plasma pre-functionalization of native PVC reproducibly increased the amount of functional groups representative of PVC additives, including ether/alcohol, esters and carboxyl groups. More specifically, we demonstrated that the O-C=O groups representative of the phthalic ester and zinc carboxylate additives identified for native PVC increased by two-fold following the RF-O(2) plasma pre-functionalization step. Although RF-O(2) pre-functionalization did not have an effect on the silver content of the NaOH/AgNO(3) treated substrates, such a modification was necessary for biomaterial products that did not have reproducible surfaces amongst production lots. XPS analysis also demonstrated that saponification with sodium hydroxide (NaOH) of esters, like those of the phthalic ester additives of PVC is a simple, irreversible method of hydrolysis, which produced sodium carboxylate and sodium phthalate salts. Exposure of native PVC to NaOH resulted in an increased surface hydrophilicity (from ca 90 degrees to ca 60 degrees ) due to dechlorination. XPS analysis following further incubation in silver nitrate demonstrated that silver ions can be trapped when the sodium of sodium carboxylate is replaced by silver after performing a second treatment with a monovalent silver-containing solution. The creation of silver salt on native PVC resulted in an ultra-hydrophobic (>120 degrees ) surface. The chemical modifications using NaOH and AgNO(3) wet treatments completely inhibited bacterial adhesion of four strains of P. aeruginosa to both native and oxygen-pre-functionalized PVC, and efficiently prevented colonization over longer periods (72 h). Our results suggest that surface modifications that incorporate silver ions would be extremely effective at reducing bacterial colonization to medical devices
Genetically programmed autoinducer destruction reduces virulence gene expression and swarming motility in Pseudomonas aeruginosa PAO1.
Virulence in the opportunistic human pathogen Pseudomonas aeruginosa is controlled by cell density via diffusible signalling molecules ('autoinducers') of the N-acylhomoserine lactone (AHL) type. Two Bacillus sp. isolates (A23 and A24) with AHL-degrading activity were identified among a large collection of rhizosphere bacteria. From isolate A24 a gene was cloned which was similar to the aiiA gene, encoding an AHL lactonase in another Bacillus strain. Expression of the aiiA homologue from isolate A24 in P. aeruginosa PAO1 reduced the amount of the quorum sensing signal N-oxododecanoyl-L-homoserine lactone and completely prevented the accumulation of the second AHL signal, N-butyryl-L-homoserine lactone. This strongly reduced AHL content correlated with a markedly decreased expression and production of several virulence factors and cytotoxic compounds such as elastase, rhamnolipids, hydrogen cyanide and pyocyanin, and strongly reduced swarming. However, no effect was observed on flagellar swimming or on twitching motility, and aiiA expression did not affect bacterial adhesion to a polyvinylchloride surface. In conclusion, introduction of an AHL degradation gene into P. aeruginosa could block cell-cell communication and exoproduct formation, but failed to interfere with surface colonization
Adhesion of Pseudomonas aeruginosa strains to untreated and oxygen-plasma treated poly(vinyl chloride) (PVC) from endotracheal intubation devices
Pseudomonas aeruginosa pneumonia is a life threatening complication in mechanically ventilated patients that requires the ability of the bacteria to adhere to, and colonize the endotracheal intubation device. New strategies to prevent or reduce these nosocomial infections are greatly needed. We report here the study of a set of P. aeruginosa clinical isolates, together with specific mutants, regarding their adhesion on native and chemically modified poly(vinyl chloride) (PVC) surfaces from endotracheal intubation devices. The adhesion of the different strains to untreated PVC varied widely, correlating with several physico-chemical characteristics known to influence the attachment of bacteria to inert surfaces. The adhesion patterns were compared to the calculations obtained with the DLVO theory of colloidal stability. These results illustrate the importance of testing different clinical isolates when investigating bacterial adhesion. Oxygen plasma treatment of the PVC pieces yielded a hydrophilic surface and reduced the number of adhering bacteria by as much as 70%. This reduction is however unlikely to be sufficient to prevent P. aeruginosa colonization of endotracheal intubation devices