6 research outputs found

    1Design of the Primary Prevention Parameters Evaluation (PREPARE) trial of implantablecardioverter defibrillators to reduce patient morbidity [NCT00279279]

    Get PDF
    BACKGROUND: Implantable Cardioverter Defibrillator (ICD) therapy has been proven to be beneficial and efficacious for the treatment of serious ventricular tachyarrhythmias in primary prevention patients. However, primary prevention patients appear to have a lower incidence of ventricular arrhythmias in comparison to secondary prevention patients and consequently likely experience a higher proportion of detections due to supraventricular arrhythmias. Recent trials have demonstrated that strategic and specific programming choices reduce the number of inappropriate shocks and that anti-tachycardia pacing (ATP) is an effective alternative to shock therapy for many sustained ventricular arrhythmias. METHODS: The Primary Prevention Parameters Evaluation (PREPARE) study is a multi-center cohort study, evaluating the efficacy of a pre-specified strategic profile of VT/VF detection and therapy settings in 700 primary prevention patients in an effort to safely reduce the number of shock therapies delivered. The patients, both with and without cardiac resynchronization therapy, are compared to a well-qualified set (n = 691) of historical controls derived from the MIRACLE ICD and EMPIRIC trials. This manuscript describes the design of the PREPARE study. The study results, to be presented separately, will characterize the efficacy of this programming set (PREPARE) compared with physician-tailored programming (MIRACLE ICD and EMPIRIC)

    A trial design for evaluation of empiric programming of implantable cardioverter defibrillators to improve patient management

    Get PDF
    The delivery of implantable cardioverter defibrillator (ICD) therapy is sophisticated and requires the programming of over 100 settings. Physicians tailor these settings with the intention of optimizing ICD therapeutic efficacy, but the usefulness of this approach has not been studied and is unknown. Empiric programming of settings such as anti-tachycardia pacing (ATP) has been demonstrated to be effective, but an empiric approach to programming all VT/VF detection and therapy settings has not been studied. A single standardized empiric programming regimen was developed based on key strategies with the intention of restricting shock delivery to circumstances when it is the only effective and appropriate therapy. The EMPIRIC trial is a worldwide, multi-center, prospective, one-to-one randomized comparison of empiric to physician tailored programming for VT/VF detection and therapy in a broad group of about 900 dual chamber ICD patients. The trial will provide a better understanding of how particular programming strategies impact the quantity of shocks delivered and facilitate optimization of complex ICD programming

    2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing☆☆☆

    Get PDF
    International audienc

    2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing

    No full text
    corecore