756 research outputs found

    In-situ early age hydration of cement-based materials by synchrotron X-ray powder diffraction

    Get PDF
    Cement based binders are building materials of worldwide importance. Since these samples are very complex, the knowledge/control of their mineralogical composition are essential to design and predict materials with specific/improved performance. Rietveld quantitative phase analysis (RQPA) allows the quantification of crystalline phases and, when combined with specific methodologies, as the addition of an internal standard or the external standard approach (G-factor), amorphous and non-crystalline phases can also be quantified. However, to carry out a proper RQPA in hydrated cementitious-materials, a good powder diffraction pattern is necessary. In this work, synchrotron X-ray powder diffraction (SXRPD) has been used, allowing in-situ measurements during the early-age hydration process. This work deals with the early hydration study of cement-based materials. The studied samples were: a laboratory-prepared belite calcium sulphoaluminate (BCSAF) clinker (non-active) mixed with 10wt% gypsum, labelled G10B0; two active laboratory-prepared BCSAF clinkers (activated with 2wt% borax), one mixed with 10wt% gypsum and the other one with 10wt% monoclinic-bassanite, hereafter named G10B2 and B10B2, respectively; and an environmentally-friendly cement sample from Henkel, composed of bassanite mixed with 15wt% Portland cement and 10wt% Metakaolin, labelled H1. Anhydrous G10B0 contains beta-belite and orthorhombic-ye'elimite as main phases, while alpha'H-belite and pseudo-cubic-ye'elimite are stabilized in G10B2 and B10B2, with the corresponding sulphate source. Anhydrous H1 contains monoclinic and hexagonal bassanite and alite as main phases. Ye'elimite, in the non-active BCSAF cement pastes, dissolves at a higher pace than in the active one (degree of reaction is α~25% and α~10% at 1 h, respectively) (both prepared with gypsum), with the corresponding differences in ettringite crystallisation (degree of precipitation is α~30% and α~5%, respectively). Moreover, the type of sulphate source has important consequences on the hydration of the active BCSAF cement pastes. Bassanite is quickly dissolved and it precipitates as gypsum within the first hour of hydration (in B10B2). At that time, ettringite starts to crystallize, and after 12 hours is almost fully crystallized, similar to G10B2. In H1, bassanite transforms into gypsum within the first hour, being the principal hydration product; ettringite starts to be formed just after few hydration minutes. These results are crucial in the understanding and development of improved cement materials.Universidad de Málaga. Campus de Excelencia Internacional Andalucía Tech

    A comparison between the chemical behaviour of lead-gold and lead-bismuth eutectics towards 316L stainless steel

    Get PDF
    Lead-gold eutectic (LGE) has been recently proposed as an alternative target material for high power spallation sources. In order to compare the corrosive properties of LGE to the better-studied eutectic of lead-bismuth (LBE), an isothermal twin-loop made of SS 316L was built and operated at the Institute of Physics of the University of Latvia. We have measured the concentration of steel alloying elements dissolved in both alloys at the end of two test campaigns via ICP-OES. In case of LGE, a pronounced concentration increase of Fe, Ni, Mn and Cr is found in the liquid metal, which is significantly higher compared to LBE. Similar results were obtained during complementary investigations on material samples exposed to both alloys in this twin-loop at 400 ◦C and 450 ◦C. These findings indicate that in contact with LGE, SS 316L steel suffers from substantial chemical attack. Detailed investigations using structure materials other than SS 316L have to be undertaken before qualifying LGE as a serious alternative to LB

    Separated cross sections in \pi^0 electroproduction at threshold at Q^2 = 0.05 GeV^2/c^2

    Full text link
    The differential cross sections \sigma_0=\sigma_T+\epsilon \sigma_L, \sigma_{LT}, and \sigma_{TT} of \pi^0 electroproduction from the proton were measured from threshold up to an additional center of mass energy of 40 MeV, at a value of the photon four-momentum transfer of Q^2= 0.05 GeV^2/c^2 and a center of mass angle of \theta=90^\circ. By an additional out-of-plane measurement with polarized electrons \sigma_{LT'} was determined. This showed for the first time the cusp effect above the \pi^+ threshold in the imaginary part of the s-wave. The predictions of Heavy Baryon Chiral Perturbation Theory are in disagreement with these data. On the other hand, the data are somewhat better predicted by the MAID phenomenological model and are in good agreement with the dynamical model DMT.Comment: 6 pages, 4 figure

    The f_LT Response Function of D(e,e'p)n at Q^2=0.33(GeV/c)^2

    Full text link
    The interference response function f_LT (R_LT) of the D(e,e'p)n reaction has been determined at squared four-momentum transfer Q^2 = 0.33 (GeV/c)^2 and for missing momenta up to p_miss= 0.29 (GeV/c). The results have been compared to calculations that reproduce f_LT quite well but overestimate the cross sections by 10 - 20% for missing momenta between 0.1 (GeV/c) and 0.2 (GeV/c) .Comment: 12 Pages, 10 figure

    New detectors for the kaon and hypernuclear experiments with KaoS at MAMI and with PANDA at GSI

    Get PDF
    The KaoS spectrometer at the Mainz Microtron MAMI, Germany, is perceived as the ideal candidate for a dedicated spectrometer in kaon and hypernuclei electroproduction. KaoS will be equipped with new read-out electronics, a completely new focal plane detector package consisting of scintillating fibres, and a new trigger system. First prototypes of the fibre detectors and the associated new front-end electronics are shown in this contribution. The Mainz hypernuclei research program will complement the hypernuclear experiments at the planned FAIR facility at GSI, Germany. At the proposed antiproton storage ring the spectroscopy of double Lambda hypernuclei is one of the four main topics which will be addressed by the PANDA Collaboration. The experiments require the operation of high purity germanium (HPGe) detectors in high magnetic fields (B= 1T) in the presence of a large hadronic background. The performance of high resolution Ge detectors in such an environment has been investigated.Comment: Presentation at International Symposium on the Development of Detectors for Particle, Astroparticle and Synchrotron Radiation Experiments, Stanford, Ca (SNIC06), 6 pages, LaTeX, 11 eps figure

    Founder populations and their uses for breast cancer genetics

    Get PDF
    Numerous founder mutations have been reported in BRCA1 and BRCA2. For genetic screening of a population with a founder mutation, testing can be targeted to the mutation, allowing for a more rapid and less expensive test. In addition, more precise estimates of the prior probability of carrying a mutation and of the likelihood of a mutation carrier developing cancer should be possible. For a given founder mutation a large number of carriers are available, so that focused scientific studies of penetrance, expression, and genetic and environmental modifiers of risk can be performed. Finally, founder populations may be a powerful resource to localize additional breast cancer susceptibility loci, because of the reduction in locus heterogeneity

    A measurement of the axial form factor of the nucleon by the p(e,e'pi+)n reaction at W=1125 MeV

    Full text link
    The reaction p(e,e'pi+)n was measured at the Mainz Microtron MAMI at an invariant mass of W=1125 MeV and four-momentum transfers of Q^2=0.117, 0.195 and 0.273 (GeV/c)^2. For each value of Q^2, a Rosenbluth separation of the transverse and longitudinal cross sections was performed. An effective Lagrangian model was used to extract the `axial mass' from experimental data. We find a value of M_A=(1.077+-0.039) GeV which is (0.051+-0.044) GeV larger than the axial mass known from neutrino scattering experiments. This is consistent with recent calculations in chiral perturbation theory.Comment: 14 pages, 5 figures, uses elsart.cl

    High-precision Studies of the 3^{\bf{3}}He(e,e^{\bf{\prime}}p) Reaction at the Quasielastic Peak

    Full text link
    Precision studies of the reaction 3^{3}He(e,e^\primep) using the three-spectrometer facility at the Mainz microtron MAMI are presented. All data are for quasielastic kinematics at q=685|\vec{q} | =685 MeV/c. Absolute cross sections were measured at three electron kinematics. For the measured missing momenta range from 10 to 165 MeV/c, no strength is observed for missing energies higher than 20 MeV. Distorted momentum distributions were extracted for the two-body breakup and the continuum. The longitudinal and transverse behavior was studied by measuring the cross section for three photon polarizations. The longitudinal and transverse nature of the cross sections is well described by a currently accepted and widely used prescription of the off-shell electron-nucleon cross-section. The results are compared to modern three-body calculations and to previous data.Comment: 4 pages, 3 figures. Submitted for publication in Phys. Rev. Let

    Coherent \pi^0 threshold production from the deuteron at Q^2 = 0.1 GeV^2/c^2

    Full text link
    First data on coherent threshold \pi^0 electroproduction from the deuteron taken by the A1 Collaboration at the Mainz Microtron MAMI are presented. At a four-momentum transfer of q^2=-0.1 GeV^2/c^2 the full solid angle was covered up to a center-of-mass energy of 4 MeV above threshold. By means of a Rosenbluth separation the longitudinal threshold s wave multipole and an upper limit for the transverse threshold s wave multipole could be extracted and compared to predictions of Heavy Baryon Chiral Perturbation Theory.Comment: 7 pages, 7 figures, latex2
    corecore