38 research outputs found

    Comparative analysis of inflamed and non-inflamed colon biopsies reveals strong proteomic inflammation profile in patients with ulcerative colitis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Accurate diagnostic and monitoring tools for ulcerative colitis (UC) are missing. Our aim was to describe the proteomic profile of UC and search for markers associated with disease exacerbation. Therefore, we aimed to characterize specific proteins associated with inflamed colon mucosa from patients with acute UC using mass spectrometry-based proteomic analysis.</p> <p>Methods</p> <p>Biopsies were sampled from rectum, sigmoid colon and left colonic flexure from twenty patients with active proctosigmoiditis and from four healthy controls for proteomics and histology. Proteomic profiles of whole colonic biopsies were characterized using 2D-gel electrophoresis, and peptide mass fingerprinting using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was applied for identification of differently expressed protein spots.</p> <p>Results</p> <p>A total of 597 spots were annotated by image analysis and 222 of these had a statistically different protein level between inflamed and non-inflamed tissue in the patient group. Principal component analysis clearly grouped non-inflamed samples separately from the inflamed samples indicating that the proteomic signature of colon mucosa with acute UC is strong. Totally, 43 individual protein spots were identified, including proteins involved in energy metabolism (triosephosphate isomerase, glycerol-3-phosphate-dehydrogenase, alpha enolase and L-lactate dehydrogenase B-chain) and in oxidative stress (superoxide dismutase, thioredoxins and selenium binding protein).</p> <p>Conclusions</p> <p>A distinct proteomic profile of inflamed tissue in UC patients was found. Specific proteins involved in energy metabolism and oxidative stress were identified as potential candidate markers for UC.</p

    Dendrimer-Based Fluorescent Indicators: In Vitro and In Vivo Applications

    Get PDF
    BACKGROUND: The development of fluorescent proteins and synthetic molecules whose fluorescence properties are controlled by the environment makes it possible to monitor physiological and pathological events in living systems with minimal perturbation. A large number of small organic dyes are available and routinely used to measure biologically relevant parameters. Unfortunately their application is hindered by a number of limitations stemming from the use of these small molecules in the biological environment. PRINCIPAL FINDINGS: We present a novel dendrimer-based architecture leading to multifunctional sensing elements that can overcome many of these problems. Applications in vitro, in living cells and in vivo are reported. In particular, we image for the first time extracellular pH in the brain in a mouse epilepsy model. CONCLUSION: We believe that the proposed architecture can represent a useful and novel tool in fluorescence imaging that can be widely applied in conjunction with a broad range of sensing dyes and experimental setups

    Gut mucosal DAMPs in IBD: From mechanisms to therapeutic implications

    Get PDF
    Endogenous damage-associated molecular patterns (DAMPs) are released during tissue damage and have increasingly recognized roles in the etiology of many human diseases. The inflammatory bowel diseases (IBD), ulcerative colitis (UC) and Crohnā€™s disease (CD), are immune-mediated conditions where high levels of DAMPs are observed. DAMPs such as calprotectin (S100A8/9) have an established clinical role as a biomarker in IBD. In this review, we use IBD as an archetypal common chronic inflammatory disease to focus on the conceptual and evidential importance of DAMPs in pathogenesis and why DAMPs represent an entirely new class of targets for clinical translation. </p

    The Current State of Proteomics in GI Oncology

    Get PDF
    Proteomics refers to the study of the entire set of proteins in a given cell or tissue. With the extensive development of protein separation, mass spectrometry, and bioinformatics technologies, clinical proteomics has shown its potential as a powerful approach for biomarker discovery, particularly in the area of oncology. More than 130 exploratory studies have defined candidate markers in serum, gastrointestinal (GI) fluids, or cancer tissue. In this article, we introduce the commonly adopted proteomic technologies and describe results of a comprehensive review of studies that have applied these technologies to GI oncology, with a particular emphasis on developments in the last 3Ā years. We discuss reasons why the more than 130 studies to date have had little discernible clinical impact, and we outline steps that may allow proteomics to realize its promise for early detection of disease, monitoring of disease recurrence, and identification of targets for individualized therapy

    Biomarkers in search of Precision Medicine in IBD

    Get PDF
    The completion of the human genome project in 2003 represented a major scientific landmark, ushering in a new era with hopes and expectations of fresh insights into disease mechanisms and treatments. In inflammatory bowel disease (IBD), many important discoveries soon followed, notably the identification of >200 genetic susceptibility loci and characterization of the gut microbiome. As ā€œbig dataā€, driven by advances in technology, becomes increasingly available and affordable, individuals with IBD and clinicians alike yearn for tangible outcomes from the promise of ā€œprecision medicineā€ā€”precise diagnosis, monitoring, and treatment. Here, we provide a commentary on the prospects and challenges of precision medicine and biomarkers in IBD. We focus on the three key areas where precision IBD will have the most impact: (1) disease susceptibility, activity, and behavior; (2) prediction of drug response and adverse effects; and (3) identification of subphenotypic mechanisms to facilitate drug discovery and selection of new treatments in IBD

    TOPICAL REVIEW: Microfluidics for flow cytometric analysis of cells and particles

    Full text link
    This review describes recent developments in microfabricated flow cytometers and related microfluidic devices that can detect, analyze, and sort cells or particles. The high-speed analytical capabilities of flow cytometry depend on the cooperative use of microfluidics, optics and electronics. Along with the improvement of other components, replacement of conventional glass capillary-based fluidics with microfluidic sample handling systems operating in microfabricated structures enables volume- and power-efficient, inexpensive and flexible analysis of particulate samples. In this review, we present various efforts that take advantage of novel microscale flow phenomena and microfabrication techniques to build microfluidic cell analysis systems.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/49182/2/pm5_3_r02.pd

    Photophysics of the fluorescent K+ indicator PBFI.

    Get PDF
    The fluorescent indicator PBFI is widely used for the determination of intracellular concentrations of K+. To investigate the binding reaction of K+ to PBFI in the ground and excited states, steady-state and time-resolved measurements were performed. The fluorescence decay surface was analyzed with global compartmental analysis yielding the following values for the rate constants at room temperature in aqueous solution at pH 7.2: k01 = 1.1 x 10(9) s-1, k21 = 2.7 x 10(8) M-1s-1, k02 = 1.8 x 10(9) s-1, and k12 = 1.4 x 10(9) s-1. k01 and k02 denote the respective deactivation rate constants of the K+ free and bound forms of PBFI in the excited state. k21 represents the second-order rate constant of binding of K+ to the indicator in the excited state whereas k12 is the first-order rate constant of dissociation of the excited K(+)-PBFI complex. From the estimated values of k12 and k21, the dissociation constant Kd* in the excited state was calculated. It was found that pKd* (-0.7) is smaller than pKd (2.2). The effect of the excited-state reaction can be neglected in the determination of Kd and/or the K+ concentration. Therefore, intracellular K+ concentrations can be accurately determined from fluorimetric measurements by using PBFI as K+ indicator
    corecore