128 research outputs found

    Gadoxetate-enhanced abbreviated MRI is highly accurate for hepatocellular carcinoma screening.

    Get PDF
    The primary objective was to compare the performance of 3 different abbreviated MRI (AMRI) sets extracted from a complete gadoxetate-enhanced MRI obtained for hepatocellular carcinoma (HCC) screening. Secondary objective was to perform a preliminary cost-effectiveness analysis, comparing each AMRI set to published ultrasound performance for HCC screening in the USA. This retrospective study included 237 consecutive patients (M/F, 146/91; mean age, 58 years) with chronic liver disease who underwent a complete gadoxetate-enhanced MRI for HCC screening in 2017 in a single institution. Two radiologists independently reviewed 3 AMRI sets extracted from the complete exam: non-contrast (NC-AMRI: T2-weighted imaging (T2wi)+diffusion-weighted imaging (DWI)), dynamic-AMRI (Dyn-AMRI: T2wi+DWI+dynamic T1wi), and hepatobiliary phase AMRI (HBP-AMRI: T2wi+DWI+T1wi during the HBP). Each patient was classified as HCC-positive/HCC-negative based on the reference standard, which consisted in all available patient data. Diagnostic performance for HCC detection was compared between sets. Estimated set characteristics, including historical ultrasound data, were incorporated into a microsimulation model for cost-effectiveness analysis. The reference standard identified 13/237 patients with HCC (prevalence, 5.5%; mean size, 33.7 ± 30 mm). Pooled sensitivities were 61.5% for NC-AMRI (95% confidence intervals, 34.4-83%), 84.6% for Dyn-AMRI (60.8-95.1%), and 80.8% for HBP-AMRI (53.6-93.9%), without difference between sets (p range, 0.06-0.16). Pooled specificities were 95.5% (92.4-97.4%), 99.8% (98.4-100%), and 94.9% (91.6-96.9%), respectively, with a significant difference between Dyn-AMRI and the other sets (p < 0.01). All AMRI methods were effective compared with ultrasound, with life-year gain of 3-12 months against incremental costs of US$ < 12,000. NC-AMRI has limited sensitivity for HCC detection, while HBP-AMRI and Dyn-AMRI showed excellent sensitivity and specificity, the latter being slightly higher for Dyn-AMRI. Cost-effectiveness estimates showed that AMRI is effective compared with ultrasound. • Comparison of different abbreviated MRI (AMRI) sets reconstructed from a complete gadoxetate MRI demonstrated that non-contrast AMRI has low sensitivity (61.5%) compared with contrast-enhanced AMRI (80.8% for hepatobiliary phase AMRI and 84.6% for dynamic AMRI), with all sets having high specificity. • Non-contrast and hepatobiliary phase AMRI can be performed in less than 14 min (including set-up time), while dynamic AMRI can be performed in less than 17 min. • All AMRI sets were cost-effective for HCC screening in at-risk population in comparison with ultrasound

    Developmental Expression of Kv Potassium Channels at the Axon Initial Segment of Cultured Hippocampal Neurons

    Get PDF
    Axonal outgrowth and the formation of the axon initial segment (AIS) are early events in the acquisition of neuronal polarity. The AIS is characterized by a high concentration of voltage-dependent sodium and potassium channels. However, the specific ion channel subunits present and their precise localization in this axonal subdomain vary both during development and among the types of neurons, probably determining their firing characteristics in response to stimulation. Here, we characterize the developmental expression of different subfamilies of voltage-gated potassium channels in the AISs of cultured mouse hippocampal neurons, including subunits Kv1.2, Kv2.2 and Kv7.2. In contrast to the early appearance of voltage-gated sodium channels and the Kv7.2 subunit at the AIS, Kv1.2 and Kv2.2 subunits were tethered at the AIS only after 10 days in vitro. Interestingly, we observed different patterns of Kv1.2 and Kv2.2 subunit expression, with each confined to distinct neuronal populations. The accumulation of Kv1.2 and Kv2.2 subunits at the AIS was dependent on ankyrin G tethering, it was not affected by disruption of the actin cytoskeleton and it was resistant to detergent extraction, as described previously for other AIS proteins. This distribution of potassium channels in the AIS further emphasizes the heterogeneity of this structure in different neuronal populations, as proposed previously, and suggests corresponding differences in action potential regulation

    Bioinorganic Chemistry of Alzheimer’s Disease

    Get PDF

    The Cycad Genotoxin MAM Modulates Brain Cellular Pathways Involved in Neurodegenerative Disease and Cancer in a DNA Damage-Linked Manner

    Get PDF
    Methylazoxymethanol (MAM), the genotoxic metabolite of the cycad azoxyglucoside cycasin, induces genetic alterations in bacteria, yeast, plants, insects and mammalian cells, but adult nerve cells are thought to be unaffected. We show that the brains of adult C57BL6 wild-type mice treated with a single systemic dose of MAM acetate display DNA damage (O6-methyldeoxyguanosine lesions, O6-mG) that remains constant up to 7 days post-treatment. By contrast, MAM-treated mice lacking a functional gene encoding the DNA repair enzyme O6-mG DNA methyltransferase (MGMT) showed elevated O6-mG DNA damage starting at 48 hours post-treatment. The DNA damage was linked to changes in the expression of genes in cell-signaling pathways associated with cancer, human neurodegenerative disease, and neurodevelopmental disorders. These data are consistent with the established developmental neurotoxic and carcinogenic properties of MAM in rodents. They also support the hypothesis that early-life exposure to MAM-glucoside (cycasin) has an etiological association with a declining, prototypical neurodegenerative disease seen in Guam, Japan, and New Guinea populations that formerly used the neurotoxic cycad plant for food or medicine, or both. These findings suggest environmental genotoxins, specifically MAM, target common pathways involved in neurodegeneration and cancer, the outcome depending on whether the cell can divide (cancer) or not (neurodegeneration). Exposure to MAM-related environmental genotoxins may have relevance to the etiology of related tauopathies, notably, Alzheimer's disease

    New bile alcohols, 5-alpha and 5-beta dermophols from amphibians

    No full text

    Evaluation of event data recorder based on crash tests

    No full text
    Event Data Recorder (EDR) is an additional function installed in airbag control module (ACM) to record vehicle and occupant information for a brief period of time before, during, and after a crash event. EDRs are now being installed in ACMs by several automakers in the USA and in Japan. The aim of this study is to understand the performance of EDRs for the improvement of accident reconstruction with more reliable information. In the first report of the study, data obtained from EDRs of seven vehicle types were evaluated using 2006-2007 J-NCAP (Japanese new car assessment program) full-lap frontal barrier crash tests and offset frontal deformable barrier crash tests data. For more practical standpoint, we conducted thirteen crash tests reconstructing typical real-world accidents such as single vehicle accidents with barriers or poles, car to car accidents and multi rear-end collisions focusing on Japanese typical accident types. Data obtained from EDRs are compared with data obtained from optical speed sensor, instrumented accelerometers and high speed video cameras. The velocities determined from pre-crash data of EDRs and the maximum change in velocity, delta-V, and delta-V time history data obtained from post-crash data of EDRs are analyzed. The results are as follows: - Pre-crash velocities of EDRs were very accurate and reliable. An average difference between the EDR recording values and reference speeds was 4.2% and a root mean square of the differences was 9.2%. Only two cases resulted large differences for the pre-crash velocity. Both of them were cases with braking prior to the collision. However, another test with braking resulted less difference. The braking condition may influence accuracy of pre-crash velocities. - Maximum delta-Vs obtained from the EDRs showed uncertainty of measurement in several cases in comparisons with the reliable delta-V data. The differences in maximum delta-V were more than 10% in five of twenty-five events data and more than 20% in two of twenty-five events data. An average of the all differences was about 4% and root mean square of the differences was about 11%. Especially large deformation at narrow area may influence accuracy of post-crash delta-V. - Multiple rear-end crash tests were reconstructed using EDRs data as case studies. Some EDRs recorded two events and a time gap between two events, so that these reconstruction case studies were very accurate and reliable. - If though only one of three vehicles in multiple rear end crash was equipped EDR, overview and velocities of all cars may be reconstructed using these limited EDR data. In this case study, leading car- EDR data and middle car- EDR data were valuable. However if only following car was equipped EDR, the reconstruction was not accurat
    corecore