536 research outputs found

    Recommendations for the use of endoscopic lung volume reduction in South Africa: Role in the treatment of emphysema

    Get PDF
    Emphysema is a very common cause of morbidity and mortality in South Africa (SA). Therapeutic options in severe emphysema are limited. Endoscopic lung volume reduction (ELVR) is increasingly being used internationally for the treatment of advanced emphysema in a subset of patients with advanced disease, aiming to obtain the same functional advantages as surgical lung volume reduction while reducing risks and costs. In addition to endobronchial valves, ELVR using endobronchial coils is now available in SA. The high cost of these interventions underscores the need for careful patient selection to best identify those who may or may not benefit from ELVR-related procedures. The Assembly on Interventional Pulmonology of the South African Thoracic Society appointed a committee comprising both local and international experts to extensively review all relevant evidence and provide advice on the use of ELVR in SA based on published evidence, expert opinion and local access to the various devices

    Influence of airway‐occluding instruments on airway pressure during jet ventilation for rigid bronchoscopy

    Get PDF
    We measured changes in airway pressure (Paw) caused by microsurgical instruments introduced into a rigid bronchoscope during high frequency jet ventilation (HFJV). With approval of the institutional Ethics Committee, 10 adults undergoing elective tracheobronchial endoscopy and endosonography during general anaesthesia were investigated. Inflation of an endosonography probe balloon in the left main stem bronchus caused airway obstruction. Pressure measurements proximal and distal to the obstruction were compared after three degrees of obstruction (0%, 50% and 90%) and with two different driving pressure settings. Airway obstruction increased the mean (sd) peak inspiratory pressure (PIP) from 7.5 (2.6) to 9.5 (3.5) mm Hg for 2 atm (P=0.0008) and from 9.7 (3.7) to 13.0 (5.1) mm Hg for 3 atm (P=0.0001). Airway obstruction did not alter peripheral PIP (7.2 (4.1) to 7.1 (3.7) mm Hg for 2 atm and 8.8 (4.3) to 9.4 (5.2) mm for 3 atm), but resulted in an end‐expiratory pressure (EEP) beyond the narrowing being significantly greater than in the unobstructed airway (2.5 (3.4) to 5.5 (3.7) mm Hg for 2 atm; P=0.0005) and 3.2 (3.6) to 8.0 (4.3) mm for 3 atm; P<0.0001). Severe airway narrowing increases inspiratory pressure proximal and expiratory pressure distal to the obstruction in relation to the applied driving pressure. Since the distal EEP never exceeded PIP, even near‐total airway obstruction should not cause severe lung distension or barotrauma in subjects with normal lungs. Br J Anaesth 2000; 85: 463-

    Living with hope: developing a psychosocial supportive program for rural women caregivers of persons with advanced cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hope is defined by caregivers as the inner strength to achieve future good and to continue care giving. Pilot test findings of a Living with Hope Program (LWHP) suggested it is an acceptable and feasible intervention for use by family caregivers. Although it shows promise in potentially increasing hope and quality of life, further testing and development is needed. Questions remain as to: a) what are the mechanisms through which the LWHP affects outcomes and b) how long it is effective? <it>The overall purpose of this time series mixed method study is the further development and testing of the LWHP by</it>:</p> <p indent="1">a. Determining the mechanisms of the LWHP by testing a LWHP conceptual model in which self-efficacy, and loss/grief are hypothesized intermediary variables for changes in hope, and subsequently quality of life among rural women caring for persons with advanced cancer, and;</p> <p indent="1">b. Exploring the longitudinal effects of the LWHP on hope, quality of life and health services utilization among rural women caring for persons with advanced cancer.</p> <p>Methods/Design</p> <p>Using a time-series embedded mixed method design, data will be collected from 200 rural women caregivers. Following the collection of baseline and outcome variables, the intervention (LWHP) is applied to all subjects. Subjects are followed over time with repeated measures of outcome variables (1 wk, 2 wk, 3, 6 and 12 months). The journals that are completed as part of the LWHP comprise the qualitative data. Health services utilization data will be collected from the Saskatchewan Health Administrative Database for all subjects one year prior and one year after study enrolment.</p> <p>Path analysis will be used to test the model post LWHP, at 1 and 2 weeks. Two-factor ANCOVA will determine patterns over time and Cortazzi's narrative analysis will be used to analyze subjects journals completed as part of the LWHP.</p> <p>Discussion</p> <p>Data Collection began January 2009 and is expected to be completed within 2 years time. Monthly meetings with data collectors and site collaborators have been instrumental in revisions to the original study protocol such as identifying and adding additional study sites.</p> <p>Trial Registration</p> <p>Trial Registration; Clinical Trials.Gov. NCT01081301</p

    Diagnostic Value of EBUS-TBNA for Lung Cancer with Non-Enlarged Lymph Nodes: A Study in a Tuberculosis-Endemic Country

    Get PDF
    BACKGROUND: In tuberculosis (TB)-endemic areas, contrast-enhanced computed tomography (CT) and positron emission tomography (PET) findings of lung cancer patients with non-enlarged lymph nodes are frequently discrepant. Endobronchial ultrasound-guided transbronchial aspiration (EBUS-TBNA) enables real-time nodal sampling, and thereby improves nodal diagnosis accuracy. This study aimed to compare the accuracy of nodal diagnosis by using EBUS-TBNA, and PET. METHODS: We studied 43 lung cancer patients with CT-defined non-enlarged mediastinal and hilar lymph nodes and examined 78 lymph nodes using EBUS-TBNA. RESULTS: The sensitivity, specificity, positive predictive value, and negative predictive value of EBUS-TBNA were 80.6%, 100%, 100%, and 85.7%, respectively. PET had low specificity (18.9%) and a low positive predictive value (44.4%). The diagnostic accuracy of EBUS-TBNA was higher than that of PET (91% vs. 47.4%; p<0.001). Compared to CT-based nodal assessment, PET yielded a positive diagnostic impact in 36.9% nodes, a negative diagnostic impact in 46.2% nodes, and no diagnostic impact in 16.9% nodes. Patients with lymph nodes showing negative PET diagnostic impact had a high incidence of previous pulmonary TB. Multivariate analysis indicated that detection of hilar nodes on PET was an independent predictor of negative diagnostic impact of PET. CONCLUSION: In a TB-endemic area with a condition of CT-defined non-enlarged lymph node, the negative diagnostic impact of PET limits its clinical usefulness for nodal staging; therefore, EBUS-TBNA, which facilitates direct diagnosis, is preferred

    A mixed methods study of hope, transitions, and quality of life in family caregivers of persons with Alzheimer's disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Several research studies have reported the poor quality of life of family caregivers of persons with Alzheimer's disease (AD). However, factors that influence their quality of life have not been clearly defined. The purpose of this study was to examine factors associated with the quality of life of these caregivers such as demographic variables, their transition experience, and hope. A secondary aim was to explore the transition experience of family caregivers of persons with AD.</p> <p>Methods</p> <p>A cross-sectional triangulation data transformation model mixed method design (Quant +Qual) was utilized to address the purpose of the study. Eighty family caregivers of persons with AD completed a survey with quantitative measures [demographic variables, Herth Hope Index (HHI-hope), World Health Organization Quality of Life -BREF (WHOQOL-BREF)] and a qualitative survey about their transitions experience. The qualitative data (transition open ended- survey) was converted to quantitative data using content analysis. Variables significant at the p < 0.10 level in the univariate analysis were entered in the multivariate generalized linear model used to determine significant factors associated with quality of life.</p> <p>Results</p> <p>Subjects with higher hope scores (p < 0.0001) (Factor 1: temporality and future-cognitive-temporary dimension of hope) and who dealt with their transitions by actively seeking out knowledge and assistance (p = 0.02) had higher overall quality of life scores. HHI scores were associated with overall quality of life and for each of the four quality of life domains (physical psychosocial, relationships, and environment).</p> <p>Conclusions</p> <p>Hope played a significant role in the subjects' perceptions of overall quality of life as well as the 4 quality of life domains. This underscores the need to develop ways to foster hope in family caregivers. Moreover, the active engagement of families in seeking information and help, as a way to deal with their transitions, suggests encouraging this engagement is important. The findings of this study also suggest many directions for future research, such as increasing our understanding of the processes of transitions for this population.</p

    The role of Endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) for qualitative diagnosis of mediastinal and hilar lymphadenopathy: a prospective analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Recently EBUS-TBNA, which has a sensitivity of 94.6%, specificity of 100% and diagnostic accuracy rate of 96.3% as previously reported, has been widely used for patients with mediastinal and hilar lymphadenopathy or suspected lung cancer to get accurate diagnosis. The purpose of the current study was to evaluate the usefulness of EBUS-TBNA in obtaining cytological and histological diagnosis of mediastinal and hilar lymph nodes compared to the results obtained with conventional mediastinoscopy as previously reported, and to assess the relationship of diagnostic accuracy and number of passes and size of lymph nodes.</p> <p>Methods</p> <p>101 patients with mediastinal and hilar lymphadenopathy or suspected lung cancer in our institution were included in this prospective study. EBUS-TBNA was performed in all cases. The final diagnosis was confirmed by cytology, surgical results, and/or clinical follow-up for at least 6 months. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated using standard formulas.</p> <p>Results</p> <p>In 101 patients, EBUS-TBNA was successfully performed to obtain samples from 225 lymph nodes, 7 lung masses, 1 mediastinal mass and 2 esophageal masses. 63 malignant tumors and 38 benign diseases were confirmed. Epidermal growth factor receptor mutation was detected in 10 biopsy samples, and epidermal growth factor receptor mutation was detected in 4 cases. With respect to the correct diagnosis of mediastinal and hilar lymphadenopathy, EBUS-TBNA had a sensitivity of 95.08%, specificity of 100%, positive predictive value of 100%, negative predictive value of 93.02%, and overall accuracy of 97.02%. The relationship of diagnostic accuracy and number of lymph node passes or size of lymph nodes was both insignificant (p = 0.27; p = 0.23). The procedure was uneventful without complications.</p> <p>Conclusions</p> <p>EBUS-TBNA is an accurate and safe tool in diagnosis of mediastinal and hilar lymphadenopathy. It cannot completely replace mediastinoscopy, it may indeed reduce the number of mediastinoscopy procedures. In some cases, it can necessarily be the first-line procedure before mediastinoscopy.</p

    The SESAMI evaluation of employment support in the UK: background and baseline data

    Get PDF
    Aims: This study evaluates real world employment support for people with severe mental health problems in the UK. Given a policy context which promotes social inclusion and welfare to work, we wanted to find out about typical employment services and their effects on people with mental health problems. Method: A case study design was adopted, incorporating qualitative and quantitative interviews with staff and users of each service. After screening for severity, 182 individuals met our inclusion criteria for current use of the services. They were interviewed about their current engagement with support services, their employment and job satisfaction if employed. Measures of self esteem, hope/optimism and job satisfaction were taken as outcomes. Results: We report here associations between the outcome measures and: current working status; support from the agency; and demographic features at baseline. People who were working had higher outcome scores than those who were in work preparation or training. People working with support had higher job satisfaction. Conclusions: The study highlights the methodological issues raised by doing real world research. These findings were generated by heterogeneous interventions in non-experimental settings. Despite this, they tend to support previous evidence in favour of early placement and ongoing support in work

    Ultra-Low Threshold cw Lasing in Tensile Strained GeSn Microdisk Cavities

    Get PDF
    GeSn is proven as a good candidate to achieve CMOS-compatible laser sources on silicon. Lasing demonstrations in this alloy were based on directness of the band structure, this directness being increased with increasing the Sn content above 8 at.%. These past few years the research were consequently focused on incorporating the highest Sn content as possible to achieve high directness and high temperature laser operation. This unfortunately results is increased threshold. In this contribution we discuss the advantages in combining tensile strain engineering with lower Sn content alloys. This approach is motivated by the higher material quality in lower Sn content. The case with Sn content as small as 5.4 at.% Sn will be discussed. The alloy is initially compressively strained, and exhibits an indirect band gap that is turned to direct by applying tensile strain. A specific technology based on transfer On Insulator stressor layer on metal was developed to address strain engineering, thermal cooling and defective interface with the Ge-VS. This led to lasing in Ge0.95Sn0.05 microdisk cavities with dramatically reduced thresholds, by two order of magnitude, as compared to the case with high Sn alloys and as consequence enables cw operation
    corecore