162 research outputs found

    Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions: an intravascular ultrasound analysis.

    Get PDF
    BACKGROUND: Incomplete stent apposition (ISA) has been previously documented after sirolimus-eluting stent (SES) implantation. The aim of this study was to investigate the long-term intravascular ultrasound (IVUS) findings of ISA in patients who received SES. METHODS AND RESULTS: A total of 13 patients who received SES and showed ISA at follow-up IVUS (follow-up I) were investigated. IVUS was performed on all of these patients 12 months later (follow-up II). Quantitative ISA area measurement was also performed at follow-up I and II. No vascular remodeling was observed in the vessel segment with ISA; external elastic membrane area was 19.4+/-6.6 versus 19.5+/-6.4 mm2 at follow-up I and II, respectively. There was also no significant change in external elastic membrane area between vessel segment with ISA and without ISA (+1.5% versus -3.0%, respectively; P=0.27) at late follow-up. The ISA area, either including (2.5+/-1.7 versus 3.8+/-6.3 mm2; P=NS) or excluding (2.5+/-1.8 versus 2.4+/-1.7 mm2; P=NS) a single patient with aneurysm formation, was not significantly different between follow-up I and II. One patient manifested a coronary aneurysm in the stented segment at late follow-up that was probably present at the initial follow-up but masked by thrombus. It was successfully treated with a covered stent. All patients were asymptomatic, and no patient experienced late thrombotic occlusion. CONCLUSIONS: Vessel dimensions and area of ISA did not change over time, except for 1 coronary aneurysm that became apparent. ISA after implantation of a SES was not associated with adverse events at late follow-up

    A novel retrospective gating method for intracoronary ultrasound images based on image properties

    Full text link
    Intracoronary ultrasound (ICUS) provides high-resolution tomographic images of selected segments of coronary arteries. Series of cross-sectional images are acquired with motorized pullback imaging catheters and used for quantitative analysis in intracoronary ultrasound studies (ICUS). Due to catheter displacement in the vascular lumen during the cardiac cycle the images that are typically acquired at 0.5 mm/s are anatomically shuffled. This results in a saw-tooth shaped appearance of the coronary segment in longitudinal reconstructed views (L-views) used frequently in quantitative coronary ultrasound (QCU) software. This paper describes a novel image-based gating method called “Intelligate”, which overcomes this problem by automatic retrospective selection of end-diastolic frames from pre-recorded ICUS studies. Our evaluation shows that there are no quantitative differences between analysis results of hardware ECG-gated and intelligated ICUS studies. 1

    Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up

    Get PDF
    BACKGROUND: Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. METHODS AND RESULTS: Fifteen patients with de novo coronary artery disease were treated with 18-mm sirolimus-eluting Bx-Velocity stents (Cordis) loaded with 140 microg sirolimus/cm2 metal surface area in a slow release formulation. Quantitative angiography (QCA) and intravascular ultrasound (IVUS) were performed according to standard protocol. Sirolimus-eluting stent implantation was successful in all 15 patients. During the in-hospital course, 1 patient died of cerebral hemorrhage after periprocedural administration of abciximab, and 1 patient underwent repeat stenting after 2 hours because of edge dissection that led to acute occlusion. Through 6 months and up to 2 years of follow-up, no additional events occurred. QCA analysis revea

    Fibrinogen storage disease without hypofibrinogenemia associated with estrogen therapy

    Get PDF
    BACKGROUND: Cytoplasmic inclusion bodies within hepatocytes may have different etiologies, including the Endoplasmic Reticulum Storage Diseases (ERSDs). ERSD is a pathological condition characterized by abnormal accumulation of proteins destined for secretion in the endoplasmic reticulum of hepatocytes; it may be congenital (primary) or acquired (secondary). Fibrinogen storage disease is a form of ERSD. CASE PRESENTATION: We present a case of fibrinogen storage disease secondary to estrogen replacement therapy. Its causal relationship to the drug is shown by histological, immunohistochemical and ultrastructural studies of paired liver biopsies obtained during and after the drug therapy. CONCLUSION: The liver biopsies of patients with idiopathic liver enzyme abnormalities should be carefully evaluated for cytoplasmic inclusion bodies and, although rare, fibrinogen deposits

    Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon- expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial

    Get PDF
    BACKGROUND: The goal of this intravascular ultrasound investigation was to provide a more detailed morphological analysis of the local biological effects of the implantation of a sirolimus-eluting stent compared with an uncoated stent. METHODS AND RESULTS: In the RAVEL trial, 238 patients with single de novo lesions were randomized to receive either an 18-mm sirolimus-eluting stent (Bx VELOCITY stent, Cordis) or an uncoated stent (Bx VELOCITY stent). In a subset of 95 patients (sirolimus-eluting stent=48, uncoated stent=47), motorized intravascular ultrasound pullback (0.5 mm/s) was performed at a 6-month follow-up. Stent volumes, total vessel volumes, and plaque-behind-stent volumes were comparable. However, the difference in neointimal hyperplasia (2+/-5 versus 37+/-28 mm3) and percent of volume obstruction (1+/-3% versus 29+/-20%) at 6 months between the 2 groups was highly significant (P<0.001), emphasizing the nearly complete abolition of the proliferative process inside the drug-eluting stent. Analysis of the proximal and distal edge volumes showed no significant difference between the 2 groups in external elastic membrane or lumen and plaque volume at the proximal and distal edges. There was also no evidence of intrastent thrombosis or persisting dissection at the stent edges. Although there was a higher incidence of incomplete stent apposition

    Impact of Virologic Breakthrough and HBIG Regimen on Hepatitis B Recurrence After Liver Transplantation

    Full text link
    The availability of hepatitis B immune globulin (HBIG) and several oral antiviral therapies has reduced but not eliminated hepatitis B virus (HBV) recurrence. We aimed to determine the rate of HBV recurrence after orthotopic liver transplantation (OLT) in relation to virologic breakthrough pre-OLT and HBIG regimens post-OLT. Data from the NIH HBV-OLT database were analyzed. A total of 183 patients transplanted between 2001 and 2007 followed for a median of 42 months (range 1–81) post-OLT were studied. At transplant, 29% were hepatitis B e antigen (HBeAg) (+), 38.5% had HBV DNA > 5 log 10 copies/mL, 74% were receiving antiviral therapy. Twenty-five patients experienced virologic breakthrough before OLT. Post-OLT, 26%, 22%, 40% and 12% of patients received intravenous (IV) high-dose, IV low-dose, intramuscular low-dose and a finite duration of HBIG, respectively as maintenance prophylaxis. All but two patients also received antiviral therapy. Cumulative rates of HBV recurrence at 1 and 5 years were 3% and 9%, respectively. Multivariate analysis showed that listing HBeAg status and HBV DNA level at OLT were the only factors associated with HBV recurrence. In conclusion, low rates of HBV recurrence can be accomplished with all the HBIG regimens used when combined with antiviral therapy including patients with breakthrough pre-OLT as long as rescue therapy is administered pre- and post-OLT.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/79358/1/j.1600-6143.2010.03046.x.pd

    Angiographic Findings of the Multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL)

    Get PDF
    BACKGROUND: Restenosis remains the major limitation of coronary catheter-based intervention. In small vessels, the amount of neointimal tissue is disproportionately greater than the vessel caliber, resulting in higher restenosis rates. In the Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) trial, approximately 40% of the vessels were small (<2.5 mm). The present study evaluates the relationship between angiographic outcome and vessel diameter for sirolimus-eluting stents. METHODS AND RESULTS: Patients were randomized to receive either an 18-mm bare metal Bx VELOCITY (BS group, n=118), or a sirolimus-eluting Bx VELOCITY stent (SES group, n=120). Subgroups were stratified into tertiles according to their reference diameter (RD; stratum I, RD 2.84 mm). At 6-month follow-up, the restenosis rate in the SES group was 0% in all strata (versus 35%, 26%, and 20%, respectively, in the BS group). In-stent late loss was 0.01+/-0.25 versus 0.80+/-0.43 mm in stratum I, 0.01+/-0.38 versus 0.88+/-0.57 mm in stratum II, and -0.06+/-0.35 versus 0.74+/-0.57 mm in stratum III (SES versus BS). In SES, the minimal lumen diameter (MLD) remained unchanged (Delta -0.72 to 0.72 mm) in 97% of the lesions and increased (=late gain, DeltaMLD <-0.72 mm) in 3% of the lesions. Multivariate predictors for late loss were treatment allocation (P<0.001) and postprocedural MLD (P= 0.008). CONCLUSIONS: Sirolimus-eluting stents prevent neointimal proliferation and late lumen loss irrespective of the vessel diameter. The classic inverse relationship between vessel diameter and restenosis rate was seen in the bare stent group but not in the sirolimus-eluting stent group

    Effectiveness of the sirolimus-eluting stent in the treatment of patients with a prior history of coronary artery bypass graft surgery

    Get PDF
    Objective: Percutaneous coronary intervention in patients with a history of previous coronary artery bypass grafting (CABG) is associated with an increased rate of subsequent adverse events compared to those without prior CABG. We evaluated the impact of utilizing the sirolimus-eluting stent (SES) in this high-risk population. Methods: Since April 2002, SES implantation was utilized as the default strategy for all percutaneous procedures in our hospital. Consecutive patients with a history of previous CABG and de novo lesions (n=47) treated exclusively with SES, were compared to 66 patients who received bare stents in the 6-month period just before SES introduction. Results: There were no significant differences between the groups (SES and bare stent) with respect to baseline clinical or lesion characteristics. The only difference between the groups related to the nominal diameter of stent utilized, which was smaller in the SES group than the bare stent group. (The maximum diameter of SES available was 3.0 mm). At 1 year, the cumulative incidence of major adverse events (defined as death, myocardial infarction, or target vessel revascularization) was significantly lower in the SES group than the bare stent group [8.5 versus 30.3%, hazard ratio 0.37 (95% confidence interval 0.15-0.91); P=0.03]. Conclusions: The utilization of the sirolimus-eluting stent for percutaneous intervention in a high-risk population with a history of previous CABG surgery is associated with a significant reduction in the rate of major adverse cardiac events at 1 year

    TAXUS III Trial: In-Stent Restenosis Treated With Stent-Based Delivery of Paclitaxel Incorporated in a Slow-Release Polymer Formulation

    Get PDF
    BACKGROUND: The first clinical study of paclitaxel-eluting stent for de novo lesions showed promising results. We performed the TAXUS III trial to evaluate the feasibility and safety of paclitaxel-eluting stent for the treatment of in-stent restenosis (ISR). METHODS AND RESULTS: The TAXUS III trial was a single-arm, 2-center study that enrolled 28 patients with ISR meeting the criteria of lesion length < or =30 mm, 50% to 99% diameter stenosis, and vessel diameter 3.0 to 3.5 mm. They were treated with one or more TAXUS NIRx paclitaxel-eluting stents. Twenty-five patients completed the angiographic follow-up at 6 months, and 17 of these underwent intravascular ultrasound (IVUS) examination. No subacute stent thrombosis occurred up to 12 months, but there was one late chronic total occlusion, and additional 3 patients showed angiographic restenosis. The mean late loss was 0.54 mm, with neointimal hyperplasia volume of 20.3 mm3. The major adverse cardiac event rate was 29% (8 patients; 1 non-Q-wave myocardial infarction, 1 coronary artery bypass grafting, and 6 target lesion revascularization [TLR]). Of the patients with TLR, 1 had restenosis in a bare stent implanted for edge dissection and 2 had restenosi
    corecore