148 research outputs found

    ESC 2019 guidelines on chronic coronary syndromes: could calcium scoring improve detection of coronary artery disease in patients with low risk score. Findings from a retrospective cohort of patients in a district general hospital.

    Get PDF
    Background: The European Society of Cardiology (ESC) published an updated stable chest pain guideline in 2019, recommending the use of an updated pre-test probability (PTP) risk score (RS) to assess the likelihood of coronary artery disease (CAD). We sought to compare the 2019 and 2013 PTPRS in a contemporary cohort of patients. Methods: 612 patients who were investigated with computed tomography coronary angiography (CTCA) for stable chest pain were included in a retrospective analysis. Results: There were 255 patients with 2019 PTPRS 15-50% with a 9% yield of severe CAD on CTCA, compared with 402 patients and a 4% yield using the 2013 PTPRS (p = 0.01). 355 patients had a 2019 PTPRS of <15%, with 3% found to have severe CAD, compared with 67 patients and none with severe CAD using the 2013 PTPRS (p = 0.14). 336 of patients with 2019 PTPRS of <15% had a calcium score as part of the CTCA. 223 of these had a zero calcium score and only one had severe CAD. In comparison, 113 patients had a positive calcium score, and 10 (9%) had severe CAD (p < 0.001). Discussion: The ESC 2019 PTPRS classifies more patients as at lower risk of CAD and hence reduces the risk overestimation associated with the 2013 PTPRS. However, in patients with a 2019 PTPRS of <15%, who would not be investigated, the use of the calcium score detected the majority of patients with significant CAD, who may benefit from secondary prevention and an associated mortality benefit as per the SCOT-Heart trial

    Normal right- and left ventricular volumes and myocardial mass in children measured by steady state free precession cardiovascular magnetic resonance

    Get PDF
    BACKGROUND: Quantification of ventricular volume by steady state free precession (SSFP) cardiovascular magnetic resonance is accurate and reproducible. Normal values exist for adults, but are lacking for children.We sought to establish normal values for left and right ventricular volumes, mass and function in healthy children by using SSFP. METHODS AND RESULTS: Fifty children (27 females, 23 males) without cardiovascular disease were evaluated. Median age was 11 years (range 7 months - 18 years), weight 35 kg (range 7-77 kg), height 146 cm (range 66-181 cm). Thirty-six examinations were performed with breath holding, 14 in freely breathing sedated children.Ventricular volumes and mass were measured in the end systolic and end diastolic phase on SSFP cine images acquired in a short axis plane as a stack of 12 contiguous slices covering full length of both ventricles. Regression analysis showed an exponential relationship between body surface area (BSA) and ventricular volumes and mass (normal value = a*BSAb). Normative curves for males and females are presented in relation to BSA for the end-diastolic volume, end-systolic volume and mass of both ventricles. Intra- and interobserver variability of the measurements was within the limits of 2% and 7% respectively, except for right ventricular mass (10%). CONCLUSION: The exponential equation for calculation of normal values for each ventricular parameter and graphical display of normative curves for data acquired in healthy children by SSFP cardiovascular magnetic resonance are provided

    Intra-observer and interobserver variability of biventricular function, volumes and mass in patients with congenital heart disease measured by CMR imaging

    Get PDF
    Cardiovascular magnetic resonance (CMR) imaging provides highly accurate measurements of biventricular volumes and mass and is frequently used in the follow-up of patients with acquired and congenital heart disease (CHD). Data on reproducibility are limited in patients with CHD, while measurements should be reproducible, since CMR imaging has a main contribution to decision making and timing of (re)interventions. The aim of this study was to assess intra-observer and interobserver variability of biventricular function, volumes and mass in a heterogeneous group of patients with CHD using CMR imaging. Thirty-five patients with CHD (7–62 years) were included in this study. A short axis set was acquired using a steady-state free precession pulse sequence. Intra-observer and interobserver variability was assessed for left ventricular (LV) and right ventricular (RV) volumes, function and mass by calculating the coefficient of variability. Intra-observer variability was between 2.9 and 6.8% and interobserver variability was between 3.9 and 10.2%. Overall, variations were smallest for biventricular end-diastolic volume and highest for biventricular end-systolic volume. Intra-observer and interobserver variability of biventricular parameters assessed by CMR imaging is good for a heterogeneous group of patients with CHD. CMR imaging is an accurate and reproducible method and should allow adequate assessment of changes in ventricular size and global ventricular function

    The costs, resource use, and cost-effectiveness of Clinical Nurse Specialist (CNSs) led interventions for patients with palliative care needs: a systematic review of international evidence

    Get PDF
    Background: Patients with palliative care (PC) needs do not access specialist palliative care services according to their necessities. Clinical Nurse Specialists (CNS) working across a variety of fields are playing an increasingly important role in the care of such patients, but there is limited knowledge of the extent to which their interventions are cost-effective. Objectives: To present results from a systematic review of the international evidence on the costs, resource use and cost effectiveness of CNS led interventions for patients palliative care needs, defined as seriously ill patients and those with advanced disease or frailty who are unlikely to be cured, recover, or stabilize. Design: Systematic review following PRISMA methodology. Data sources: Medline, Embase, Cinahl and Cochrane library up to 2015. Studies focusing on the outcomes of CNS interventions for patients with PC needs, and including at least one economic outcome, were considered. The quality of studies was assessed using tools from the Joanna-Briggs-Institute. Results: A total of 79 papers were included: 37 RCTs, 22 quasi-experimental studies, 7 service evaluations and other studies, and 13 economic analyses. The studies included a wide variety of interventions including clinical, support and education, as well as care coordination activities. The quality of the studies varied greatly. Conclusions: CNSs interventions may be effective in reducing specific resource use such as hospitalizations /re-hospitalizations/admissions, length of stay, and health care costs. There is mixed evidence regarding their cost-effectiveness. Future studies should ensure that clinical nurse specialists’ roles and activities are clearly described and evaluated

    Electrocardiographic diagnosis of left ventricular hypertrophy in aortic valve disease: evaluation of ECG criteria by cardiovascular magnetic resonance

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Left ventricular hypertrophy (LVH) is a hallmark of chronic pressure or volume overload of the left ventricle and is associated with risk of cardiovascular morbidity and mortality. The purpose was to evaluate different electrocardiographic criteria for LVH as determined by cardiovascular magnetic resonance (CMR). Additionally, the effects of concentric and eccentric LVH on depolarization and repolarization were assessed.</p> <p>Methods</p> <p>120 patients with aortic valve disease and 30 healthy volunteers were analysed. As ECG criteria for LVH, we assessed the Sokolow-Lyon voltage/product, Gubner-Ungerleider voltage, Cornell voltage/product, Perugia-score and Romhilt-Estes score.</p> <p>Results</p> <p>All ECG criteria demonstrated a significant correlation with LV mass and chamber size. The highest predictive values were achieved by the Romhilt-Estes score 4 points with a sensitivity of 86% and specificity of 81%. There was no difference in all ECG criteria between concentric and eccentric LVH. However, the intrinsicoid deflection (V6 37 ± 1.0 ms vs. 43 ± 1.6 ms, p < 0.05) was shorter in concentric LVH than in eccentric LVH and amplitudes of ST-segment (V5 -0.06 ± 0.01 vs. -0.02 ± 0.01) and T-wave (V5 -0.03 ± 0.04 vs. 0.18 ± 0.05) in the anterolateral leads (p < 0.05) were deeper.</p> <p>Conclusion</p> <p>By calibration with CMR, a wide range of predictive values was found for the various ECG criteria for LVH with the most favourable results for the Romhilt-Estes score. As electrocardiographic correlate for concentric LVH as compared with eccentric LVH, a shorter intrinsicoid deflection and a significant ST-segment and T-wave depression in the anterolateral leads was noted.</p

    3D Echo systematically underestimates right ventricular volumes compared to cardiovascular magnetic resonance in adult congenital heart disease patients with moderate or severe RV dilatation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Three dimensional echo is a relatively new technique which may offer a rapid alternative for the examination of the right heart. However its role in patients with non-standard ventricular size or anatomy is unclear. This study compared volumetric measurements of the right ventricle in 25 patients with adult congenital heart disease using both cardiovascular magnetic resonance (CMR) and three dimensional echocardiography.</p> <p>Methods</p> <p>Patients were grouped by diagnosis into those expected to have normal or near-normal RV size (patients with repaired coarctation of the aorta) and patients expected to have moderate or worse RV enlargement (patients with repaired tetralogy of Fallot or transposition of the great arteries). Right ventricular end diastolic volume, end systolic volume and ejection fraction were compared using both methods with CMR regarded as the reference standard</p> <p>Results</p> <p>Bland-Altman analysis of the 25 patients demonstrated that for both RV EDV and RV ESV, there was a significant and systematic under-estimation of volume by 3D echo compared to CMR. This bias led to a mean underestimation of RV EDV by -34% (95%CI: -91% to + 23%). The degree of underestimation was more marked for RV ESV with a bias of -42% (95%CI: -117% to + 32%). There was also a tendency to overestimate RV EF by 3D echo with a bias of approximately 13% (95% CI -52% to +27%).</p> <p>Conclusions</p> <p>Statistically significant and clinically meaningful differences in volumetric measurements were observed between the two techniques. Three dimensional echocardiography does not appear ready for routine clinical use in RV assessment in congenital heart disease patients with more than mild RV dilatation at the current time.</p

    Age and gender specific normal values of left ventricular mass, volume and function for gradient echo magnetic resonance imaging: a cross sectional study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Knowledge about age-specific normal values for left ventricular mass (LVM), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) by cardiac magnetic resonance imaging (CMR) is of importance to differentiate between health and disease and to assess the severity of disease. The aims of the study were to determine age and gender specific normal reference values and to explore the normal physiological variation of these parameters from adolescence to late adulthood, in a cross sectional study.</p> <p>Methods</p> <p>Gradient echo CMR was performed at 1.5 T in 96 healthy volunteers (11–81 years, 50 male). Gender-specific analysis of parameters was undertaken in both absolute values and adjusted for body surface area (BSA).</p> <p>Results</p> <p>Age and gender specific normal ranges for LV volumes, mass and function are presented from the second through the eighth decade of life. LVM, ESV and EDV rose during adolescence and declined in adulthood. SV and EF decreased with age. Compared to adult females, adult males had higher BSA-adjusted values of EDV (p = 0.006) and ESV (p < 0.001), similar SV (p = 0.51) and lower EF (p = 0.014). No gender differences were seen in the youngest, 11–15 year, age range.</p> <p>Conclusion</p> <p>LV volumes, mass and function vary over a broad age range in healthy individuals. LV volumes and mass both rise in adolescence and decline with age. EF showed a rapid decline in adolescence compared to changes throughout adulthood. These findings demonstrate the need for age and gender specific normal ranges for clinical use.</p
    corecore