35 research outputs found

    Metal-support interaction and charge distribution in ceria-supported Au particles exposed to CO

    Full text link
    Understanding how reaction conditions affect metal-support interactions in catalytic materials is one of the most challenging tasks in heterogeneous catalysis research. Metal nanoparticles and their supports often undergo changes in structure and oxidation state when exposed to reactants, hindering a straightforward understanding of the structure-activity relations using only ex situ or ultrahigh vacuum techniques. Overcoming these limitations, we explored the metal-support interaction between gold nanoparticles and ceria supports in ultrahigh vacuum and after exposure to CO. A combination of in situ methods (on powder and model Au/CeO2 samples) and theoretical calculations was applied to investigate the gold/ceria interface and its reactivity toward CO exposure. X-ray photoelectron spectroscopy measurements rationalized by first-principles calculations reveal a distinctly inhomogeneous charge distribution, with Au+ atoms in contact with the ceria substrate and neutral Au0 atoms at the surface of the Au nanoparticles. Exposure to CO partially reduces the ceria substrate, leading to electron transfer to the supported Au nanoparticles. Transferred electrons can delocalize among the neutral Au atoms of the particle or contribute to forming inert Auδ− atoms near oxygen vacancies at the ceria surface. This charge redistribution is consistent with the evolution of the vibrational frequencies of CO adsorbed on Au particles obtained using diffuse reflectance infrared Fourier transform spectroscopy

    Mathematical based control method and performance analysis of a novel hydromechatronics driving system Micro-Independent Metering

    Get PDF
    This paper aims to investigate the performance of a hydraulic actuator controlled by the novel system micro-independent metering (MIM). This analysis has been performed by comparing the models of two systems which are the traditional independent metering, that depends on poppet valve, and the new hydro-mechatronics system micro-independent metering, that relies on a stepped rotary flow control valve. In general, independent metering is a hydraulic control system which guarantees a separation between the meter-in and the meter-out of the hydraulic actuator. A Valvistor valve, a special type of Poppet valves, was developed to be embedded into the independent metering (IM) system. This valve has controllability and stability shortcomings which prevent the system from spreading in the industrial applications. The Valvistor valve performance is highly affected by the fluid disturbances because the fluid is considered as a part of its control elements. A stepped rotary flow control valve has been developed to control hydraulic flow rate. The valve composed of a rotary orifice attached to a stepper motor. Using this valve instead of the traditional poppet type has led to a new configuration, that is termed by micro-independent metering. This form improves the hydraulic cylinder velocity performance by rejecting the fluid disturbances effect on the control circuit

    Kapitel 9: Polen

    No full text

    Bisectional 5th harmonic filter for reactive power compensation of pipe rolling mill drives

    No full text
    The article deals with a designed and practically applied bisectional passive filter that works as a reactive power compensator as well as suppresses the 5th harmonic of the supply voltage. There are presented calculations concerning harmonic currents in the supply power and in the switched sections of the 5th harmonic filter. The calculations are illustrated by diagrams of current transfer functions versus the harmonic order. In the second part of the article there are presented time variations of parameters of the electric Power consumed by a high power dc converter drive applied to a pipe rolling mill. These quantities include: Power factor tg?, the mean phase current in the supply circuit and the percentage content of the chase voltage 5th harmonic for different configurations of the filter compensator. The presented measurements and analysis allow to formulate conclusions and design recommendations

    Diagnostics of a ladle furnace transformer after damage repair

    No full text
    The paper presents results of diagnostic tests of a ladle furnace transformer conducted after damage repair, before putting the ladle to operation. In the tests, the waveforms of voltages and currents were recorded digitally on the primary and secondary side of the transformer in no-load as well as in under-load state. Additional temperature measurements of the transformer casing during its operation, conducted with an infrared camera, are also presented. The recorded data were numerically processed. The results made it possible to assess condition of the transformer components (core, windings and casing), indicate hazards and formulate operation recommendations

    Analysis of load and losses in converter transformers of electric drives

    No full text
    Electric converter drives are nonlinear loads that produce higher harmonics of current. To reduce their influence on quality of electric energy in a power network, medium and high power drives are fed from separate converter transformers. The secondary current of these transformers are non-sinusoidal due to properties of converters and, sometimes, the supply voltage is also distorted. A non-sinusoidal current and voltage with significant content of higher harmonics result in additional power losses and heating of a transformer. As a result, due to thermal effects, the transformed power has to be reduced in comparison to nominal power specified for a linear load. The article deals with analysis of load and losses of transformers feeding frequency converters and controlled rectifiers of steelworks drives. Necessary reductions of transformers nominal power due to non-sinusoidal load current are determined on the basis of harmonic spectra of recorded waveforms of voltages and currents

    Variable frequency drives of overhead crane with gripper

    No full text
    The paper describes the structure and properties of the overhead crane drives. They allow the movement of the transported item in three axes: x (driving the bridge), y (driving the trolley) and z (lifting - lowering). Drive systems are equipped with squirrel cage induction motors powered by frequency converters. Control of the crane is supported with PLC. The temporal waveforms of the basic quantities of electro-mechanical drives for lifting and lowering the weight and during its horizontal transport along the x and y axis are presented. DriveWindow software tool was used to record the signals. This software is dedicated to the parameterization and monitoring of the ABB drive systems.W artykule opisano struktury i właściwości napędów mechanizmów suwnicy chwytakowej. Umożliwiają one przemieszczenie transportowanego elementu w trzech osiach: x (jazda mostem), y (jazda wózkiem) oraz z (podnoszenie - opuszczanie). Układy napędowe wyposażone są w silniki asynchroniczne klatkowe zasilane z przemienników częstotliwości. Sterowanie pracą suwnicy wspomagane jest sterownikiem PLC. Zamieszczono przebiegi czasowe podstawowych wielkości elektromechanicznych dla napędów suwnicy przy podnoszeniu i opuszczaniu ciężaru oraz podczas jego transportu poziomego wzdłuż osi x i y. Do rejestracji przebiegów wykorzystano oprogramowanie narzędziowe DriveWindow dedykowane do parametryzacji oraz monitorowania pracy przekształtnikowych układów napędowych firmy ABB

    Selected problems of reactive power compensation and higher harmonics filtering in modernized converter drives

    No full text
    The paper deals with requirements that have to be met in design and modernization of electric converter drives. Technical issues connected with compensation of the reactive power and filtering of higher harmonice of the current, occurring during implementation and operation of the drives, are described using selected examples. One of the problems is increase of the voltage distortion at buses of a medium voltage switching station due to mismatch between the LC filter parameters and the current harmonic spectrum after replacing controlled DC drives of the bar rolling mill with squirrel cage motors with frequency converters. Negative effect of the idle run current compensation circuit of a new dry transformer on valve switching in the controlled rectifier after replacing old oil transformers is also described. Diagrams of supply circuits, waveforms of currents and voltages as well as harmonic spectra illustrating discussed problems are presented and conclusions and recommendations are formulated

    Experimental measurements of parameters and characteristics of the arc furnace electrodes hydraulic drive

    No full text
    W artykule przedstawiono wyniki pomiarów parametrów i charakterystyk regulacyjnych hydraulicznego napędu elektrod pieca łukowego AC dużej mocy. Opisano układ sterowania i regulacji położenia elektrod z siłownikami hydraulicznymi. Do bezpośredniego pomiaru położenia elektrod pieca użyto laserowych czujników odległości, podłączonych do komputera pomiarowego. Wyznaczono charakterystyki położenia i prędkości elektrod dla różnych stanów pracy oraz pokazano dynamiczne przebiegi czasowe ruchu elektrod w różnych fazach wytopu. Sformułowano wnioski dotyczące nastaw w układzie sterowania elektrod pieca.The article presents the results of measurements of the parameters and characteristics of the hydraulic control of electrodes of high power AC arc furnace. The control and positioning system of the electrodes with hydraulic actuators has been described. Laser distance sensors connected to the measuring computer were used for the direct measurement of the position of AC furnace electrodes. The control signals for the electromagnetic valves were also measured. DasyLab and Matlab software were used for the data acquisition and analysis. The position and speed characteristics of the electrodes for various operating states have been determined. Dynamic characteristics of the electrodes movement in the various melting phases are shown. Conclusions on settings in the furnace electrodes control system were formulated

    Asymmetry of the linear speed of multi-motor controlled DC drive

    No full text
    The paper presents the structure and properties of the unit comprising several groups of multi-motors DC drives. The unit drives the transport line of molded steel band. Each drive group is controlled by the SCR rectifier in armature circuits. Excitation circuits of the group of motors are powered from a single semicontrolled rectifier with additional resistors to set the individual excitation currents. The result of technological conditions associated with hydraulic clamp, geometrical deviations of drive rollers, thermal conditions and elasticity of the band is the occurrence of asymmetric linear velocity that determine specific defects of the slabs. Linear speeds of transport rollers were calculated using encoders to measure the speed of motors and programs DasyLab and MATLAB. Asymmetry of the linear speeds of rollers was determined. The summary and conclusions are presented at the end of the paper.Artykuł przedstawia strukturę i właściwości zespołu wielosilnikowych napędów grupowych DC transportującego formowane pasmo metalu. Każda z grup napędowych jest sterowana przekształtnikiem tyrystorowym od strony obwodu tworników. Obwody wzbudzenia silników grupy są zasilane z jednego prostownika półsterowanego z dodatkowymi rezystorami do indywidualnego ustawiania prądów wzbudzenia. Rezultatem uwarunkowań technologicznych związanych z dociskiem hydraulicznym, niedoskonałością geometryczną rolek napędowych, warunkami termicznymi i plastycznością pasma jest występowanie asymetrii prędkości liniowych, które determinują określone wady półproduktu. Wykorzystując enkodery do pomiaru prędkości obrotowej silników i rolek transportowych oraz programy DasyLab i MATLAB obliczono wartości prędkości liniowych, na podstawie których określono stopień asymetrii prędkości liniowych rolek. W końcowej części artykułu przedstawiono podsumowanie i wnioski
    corecore