21 research outputs found

    Steps toward accurate large-area analyses of Genesis solar wind samples: evaluation of surface cleaning methods using total reflection X-ray fluorescence spectrometry

    Get PDF
    Total reflection X-ray fluorescence spectrometry (TXRF) was used to analyze residual surface contamination on Genesis solar wind samples and to evaluate different cleaning methods. To gauge the suitability of a cleaning method, two samples were analyzed following cleaning by lab-based TXRF. The analysis comprised an overview and a crude manual mapping of the samples by orienting them with respect to the incident X-ray beam in such a way that different regions were covered. The results show that cleaning with concentrated hydrochloric acid and a combination of hydrochloric acid and hydrofluoric acid decreased persistent inorganic contaminants substantially on one sample. The application of CO2 snow for surface cleaning tested on the other sample appears to be effective in removing one persistent Genesis contaminant, namely germanium. Unfortunately, the TXRF analysis results of the second sample were impacted by relatively high background contamination. This was mostly due to the relatively small sample size and that the solar wind collector was already mounted with silver glue for resonance ion mass spectrometry (RIMS) on an aluminium stub. Further studies are planned to eliminate this problem. In an effort to identify the location of very persistent contaminants, selected samples were also subjected to environmental scanning electron microscopy. The results showed excellent agreement with TXRF analysis

    The isotopic composition and fluence of solar-wind nitrogen in a genesis B/C array collector

    Get PDF
    We have measured the isotopic composition and fluence of solar-wind nitrogen in a diamond-like-carbon collector from the Genesis B/C array. The B and C collector arrays on the Genesis spacecraft passively collected bulk solar wind for the entire collection period, and there is no need to correct data for instrumental fractionation during collection, unlike data from the Genesis “Concentrator.” This work validates isotopic measurements from the concentrator by Marty et al. (2010, 2011); nitrogen in the solar wind is depleted in ^(15)N relative to nitrogen in the Earth’s atmosphere. Specifically, our array data yield values for ^(15)N/^(14)N of (2.17 ± 0.37) × 10^(−3) and (2.12 ± 0.34) × 10^(−3), depending on data-reduction technique. This result contradicts preliminary results reported for previous measurements on B/C array materials by Pepin et al. (2009), so the discrepancy between Marty et al. (2010, 2011) and Pepin et al. (2009) was not due to fractionation of solar wind by the concentrator. Our measured value of ^(15)N/^(14)N in the solar wind shows that the Sun, and by extension the solar nebula, lie at the low-^(15)N/^(14)N end of the range of nitrogen isotopic compositions observed in the solar system. A global process (or combination of processes) must have operated in interstellar space and/or during the earliest stages of solar system formation to increase the ^(15)N/^(14)N ratio of the solar system solids. We also report a preliminary Genesis solar-wind nitrogen fluence of (2.57 ± 0.42) × 10^(12) cm^(−2). This value is higher than that derived by backside profiling of a Genesis silicon collector (Heber et al. 2011a)

    Partial melting of ordinary chondrites: Lost City (H) and St. Severin (LL)

    Get PDF
    Eucrites and diogenites are examples of asteroidal basalts and orthopyroxenites, respectively. As they are found intermingled in howardites, which are inferred to be regolith breccias, eucrites and diogenites are thought to be genetically related. But the details of this relationship and of their individual origins remain controversial. Work by Jurewicz et al. showed that 1170-1180 C partial melts of the (anhydrous) Murchison (CM) chondrite have major element compositions extremely similar to primitive eucrites, such as Sioux County. However, the MnO contents of these melts were about half that of Sioux County, a problem for the simple partial melting model. In addition, partial melting of Murchison could not produce diogenites, because residual pyroxenes in the Murchison experiments were too Fe- and Ca-rich and were minor phases at all but the lowest temperatures. A parent magma for diogenites needs an expanded low-calcium pyroxene field. In their partial melting study of an L6 chondrite, Kushiro and Mysen found that ordinary chondrites did have an expanded low-Ca pyroxene field over that of CV chondrites (i.e., Allende), probably because ordinary chondrites have lower Mg/Si ratios. This study expands that of both Kushiro and Mysen and Jurewicz et al. to the Lost City (H) and St. Severin (LL) chondrites at temperatures ranging from 1170 to 1325 C, at an fO2 of one log unit below the iron-wuestite buffer (IW-1)

    Electron Microprobe/SIMS Determinations of Al in Olivine: Applications to Solar Wind, Pallasites and Trace Element Measurements

    Get PDF
    Electron probe microanalyser measurements of trace elements with high accuracy are challenging. Accurate Al measurements in olivine are required to calibrate SIMS implant reference materials for measurement of Al in the solar wind. We adopt a combined EPMA/SIMS approach that is useful for producing SIMS reference materials as well as for EPMA at the ~100 ”g g⁻Âč level. Even for mounts not polished with alumina photoelectron spectroscopy shows high levels of Al surface contamination. In order to minimise electron beam current density, a rastered 50 × 100 ”m electron beam was adequate and minimised sensitivity to small Al‐rich contaminants. Reproducible analyses of eleven SIMS cleaned spots on San Carlos olivine agreed at 69.3 ± 1.0 ”g g⁻Âč. The known Al mass fraction was used to calibrate an Al implant into San Carlos. Accurate measurements of Al were made for olivines in the pallasites: Imilac, Eagle Station and Springwater. Our focus was on Al in olivine; but our technique could be refined to give accurate electron probe measurements for other contamination‐sensitive trace elements. For solar wind it is projected that the Al/Mg abundance ratio can be determined to 6%, a factor of 2 more precise than the solar spectroscopic ratio

    Electron Microprobe/SIMS Determinations of Al in Olivine: Applications to Solar Wind, Pallasites and Trace Element Measurements

    Get PDF
    Electron probe microanalyser measurements of trace elements with high accuracy are challenging. Accurate Al measurements in olivine are required to calibrate SIMS implant reference materials for measurement of Al in the solar wind. We adopt a combined EPMA/SIMS approach that is useful for producing SIMS reference materials as well as for EPMA at the ~100 ”g g⁻Âč level. Even for mounts not polished with alumina photoelectron spectroscopy shows high levels of Al surface contamination. In order to minimise electron beam current density, a rastered 50 × 100 ”m electron beam was adequate and minimised sensitivity to small Al‐rich contaminants. Reproducible analyses of eleven SIMS cleaned spots on San Carlos olivine agreed at 69.3 ± 1.0 ”g g⁻Âč. The known Al mass fraction was used to calibrate an Al implant into San Carlos. Accurate measurements of Al were made for olivines in the pallasites: Imilac, Eagle Station and Springwater. Our focus was on Al in olivine; but our technique could be refined to give accurate electron probe measurements for other contamination‐sensitive trace elements. For solar wind it is projected that the Al/Mg abundance ratio can be determined to 6%, a factor of 2 more precise than the solar spectroscopic ratio

    Solar Wind Neon from Genesis: Implications for the Lunar Noble Gas Record

    Get PDF
    Lunar soils have been thought to contain two solar noble gas components with distinct isotopic composition. One has been identified as implanted solar wind, the other as higher-energy solar particles. The latter was puzzling because its relative amounts were much too large compared with present-day fluxes, suggesting periodic, very high solar activity in the past. Here we show that the depth-dependent isotopic composition of neon in a metallic glass exposed on NASA's Genesis mission agrees with the expected depth profile for solar wind neon with uniform isotopic composition. Our results strongly indicate that no extra high-energy component is required and that the solar neon isotope composition of lunar samples can be explained as implantation-fractionated solar wind

    Depth profiling analysis of solar wind helium collected in diamond-like carbon film from Genesis

    Get PDF
    The distribution of solar-wind ions in Genesis mission collectors, as determined by depth profiling analysis, constrains the physics of ion-solid interactions involving the solar wind. Thus, they provide an experimental basis for revealing ancient solar activities represented by solar-wind implants in natural samples. We measured the first depth profile of ^4He in a Genesis collector; the shallow implantation (peaking at <20 nm) required us to use sputtered neutral mass spectrometry with post-photoionization by a strong field. The solar wind He fluence calculated using depth profiling is ~8.5 × 10^(14) cm^(–2). The shape of the solar wind 4He depth profile is consistent with TRIM simulations using the observed ^4He velocity distribution during the Genesis mission. It is therefore likely that all solar-wind elements heavier than H are completely intact in this Genesis collector and, consequently, the solar particle energy distributions for each element can be calculated from their depth profiles. Ancient solar activities and space weathering of solar system objects could be quantitatively reproduced by solar particle implantation profiles
    corecore