9 research outputs found

    Colorectal cancer liver metastases: laparoscopic and open radiofrequency-assisted surgery

    Get PDF
    Introduction: The liver is the most common site of colorectal metastases (colorectal liver metastases – CLM). Surgical treatment in combination with oncological therapy is the only potentially curative method. Unfortunately, only 10–25% of patients are suitable for surgery. Traditionally, open liver resection (OLR) is usually performed. However, laparoscopic liver resection (LLR) has become popular worldwide in the last two decades. Aim: To evaluate the effectiveness and benefits of radiofrequency minor LLR of CLM in comparison with OLR. Material and methods: The indication for surgery was CLM and the possibility to perform minor laparoscopic or OLR not exceeding two hepatic segments according to Couinaud’s classification. Results: Sixty-six minor liver resections for CLM were performed. Twenty-five (37.9%) patients underwent a laparoscopic approach and 41 (62.1%) patients underwent OLR. The mean operative time was 166.4 min for LLR and 166.8 min for OLR. Average blood loss was 132.3 ±218.0 ml during LLR and 149.5 ±277.5 ml during OLR. Length of hospital stay was 8.4 ±2.0 days for LLR and 10.5 ±5.8 days for OLR. All resections were R0. There was no case of mortality. Postoperative complications were recognized in 9 (13.6%) patients: 8 in the group of OLR patients and 1 in the LLR group. The median survival time for LLR was 70.5 months and for OLR 61.9 months. The 5-year overall survival rate was higher for LLR vs. OLR – 82.1% vs. 69.8%. The average length of disease-free interval after LLR was greater (52.2 months) in comparison with OLR (49.4%). The 5-year disease-free interval was 63.2% for LLR and 58% for OLR. Conclusions: Outcomes and oncological radicality of minor laparoscopic liver resections of CLM are comparable to outcomes of OLR.Web of Science10221220

    New semi-spherical radiofrequency energy device for liver resection: an experimental study in pigs

    Get PDF
    The aim of this experimental study was to verify a new semi-spherical surgical tool for bipolar radiofrequency liver ablation, which can solve some of the disadvantages of the commonly used device, such as long duration of ablation. A total of 12 pigs which were randomly divided into two groups were used. Each pig underwent resection of the two liver lobes. In group 1, pigs were treated with the commonly used device; in group 2 the newly developed semispherical device was used. During surgery and the post-surgical period, many categories were observed and later analyzed. The blood count and biochemistry were monitored on days 0, 14 and 30 from the operation. On day 14 since the liver resection, pigs underwent diagnostic laparoscopy to evaluate their condition focusing on the site of the liver lobe resection. On day 30 after operation, all pigs were euthanized and subjected to histopathological examination. Histopathological evaluation of thermal changes at the resection margin showed strong thermal alteration in both groups. Data between both groups were compared using median test for continuous variables and Fisher’s exact test for categorical variables. Statistical analyses were performed with IBM SPSS software version 18.0. Statistical analysis of collected data did not prove any significant (P < 0.05) differences between the commonly used device and the newly designed surgical tool.Web of Science84439

    Therapeutic Potential of Adipose-Derived Therapeutic Factor Concentrate for Treating Critical Limb Ischemia

    Get PDF
    Transplantation of adipose-derived stem cells (ADSCs) is an emerging therapeutic option for addressing intractable diseases such as critical limb ischemia (CLI). Evidence suggests that therapeutic effects of ADSCs are primarily mediated through paracrine mechanisms rather than transdifferentiation. These secreted factors can be captured in conditioned medium (CM) and concentrated to prepare a therapeutic factor concentrate (TFC) composed of a cocktail of beneficial growth factors and cytokines that individually and in combination demonstrate disease-modifying effects. The ability of a TFC to promote reperfusion in a rabbit model of CLI was evaluated. A total of 27 adult female rabbits underwent surgery to induce ischemia in the left hindlimb. An additional five rabbits served as sham controls. One week after surgery, the ischemic limbs received intramuscular injections of either (1) placebo (control medium), (2) a low dose of TFC, or (3) a high dose of TFC. Limb perfusion was serially assessed with a Doppler probe. Blood samples were analyzed for growth factors and cytokines. Tissue was harvested postmortem on day 35 and assessed for capillary density by immunohistochemistry. At 1 month after treatment, tissue perfusion in ischemic limbs treated with a high dose of TFC was almost double (p < 0.05) that of the placebo group [58.8 ± 23 relative perfusion units (RPU) vs. 30.7 ± 13.6 RPU; mean ± SD]. This effect was correlated with greater capillary density in the affected tissues and with transiently higher serum levels of the angiogenic and prosurvival factors vascular endothelial growth factor (VEGF) and hepatocyte growth factor (HGF). The conclusions from this study are that a single bolus administration of TFC demonstrated robust effects for promoting tissue reperfusion in a rabbit model of CLI and that a possible mechanism of revascularization was promotion of angiogenesis by TFC. Results of this study demonstrate that TFC represents a potent therapeutic cocktail for patients with CLI, many of whom are at risk for amputation of the affected limb

    Critical and creative thinking at education and research

    No full text
    Monograph provides an overview of current concepts of critical and creative thinking in the context of education and key competencies of the individual. The authors divided the monograph into two dimensions, theoretical and empirical. Theoretical dimension discusses and defines the personality and the cognitive psychology of individuals, key competencies, critical thinking and creative thinking. These themes are summarized in the conclusion of the theoretical dimension to the schema, which characterizes the relationship between personality, critical and creative thinking. The empirical dimension presents the results of the research, which is engaged in exploration of the critical and creative thinking in tertiary education. The authors clearly define the terms and summarize research data, ideas and suggestions that enable a comprehensive view on the issue.

    Radiofrequency-assisted liver resections: comparison of open and laparoscopic techniques

    No full text
    DOI nefunkčníBackground/Aims: After the first reported laparoscopic liver resection (LLR) twenty years ago, liver surgery still remains one of the last areas of resistance to the offensive of laparoscopy. Radiofrequency assisted laparoscopic liver resection has been recently developed technique for treatment of primary and secondary liver tumors. Methodology: Over a 5-year period, a total of 134 laparoscopic and open radiofrequency assisted operations were performed in a single institution. LLR was done in 47 patients, and open liver resection (OLR) in 87 patients. Results: The study selection criteria were fulfilled by 134 patients. The mean blood loss for LLR was 68.7mL, the difference between the groups was significant with lower median of blood loss using laparoscopy (p=0.046). The mean of length of hospital stay in LLR was 7.5 days versus 8.7 days in OLR (p=0.071). The 5- year survival rate was 67.0% after LLR and 63.8% after OLR. The 5- year disease-free survival rate was 59.4% after LLR, and 62.2% after OLR. The difference between groups was not statistically significant. Conclusions: Laparoscopic liver resection is safe and feasible procedure. The hand-assisted laparoscopic radiofrequency technique can be applied effectively for selected patients. Preliminary oncological results suggest non-inferiority of laparoscopic to open procedures.Web of Science611362366235

    Semi-spherical Radiofrequency Bipolar Device - A New Technique for Liver Resection: Experimental In Vivo Study on the Porcine Model

    No full text
    PubMed ID: 24945372The incidence of colorectal carcinoma is still growing in the Czech Republic and also all around the world. With success of oncological treatment is also growing a number of potential patients with liver metastases, who can profit from surgical therapy. The aim of this study was to confirm on porcine models that this method by using new surgical device is effective and safe for patients who have to undergo liver resection. The primary hypothesis of the study was to evaluate whether this new device is able to consistently produce homogeneous and predictable areas of coagulation necrosis without the Pringle maneuver of vascular inflow occlusion. The secondary hypothesis of the study was to compare the standard linear radiofrequency device and a new semi-spherical bipolar device for liver ablation and resection in a hepatic porcine model. Twelve pigs were randomly divided into two groups. Each pig underwent liver resection from both liver lobes in the marginal, thinner part of liver parenchyma. The pigs in first group were operated with standard using device and in the second group we used new developed semi-spherical device. We followed blood count in 0th, 14th and 30th day from operation. 14th day from resection pigs underwent diagnostic laparoscopy to evaluate of their state, and 30th day after operation were all pigs euthanized and subjected to histopathological examination. Histopathological evaluation of thermal changes at the resection margin showed strong thermal alteration in both groups. Statistical analysis of collected dates did not prove any significant (p < 0.05) differences between standard using device and our new surgical tool. We proved safety of new designed semi-spherical surgical. This device can offer the possibility of shortening the ablation time and operating time, which is benefit for patients undergoing the liver resection.Web of Science14558257
    corecore