5 research outputs found

    Hierarchical structures of anodised cold gas sprayed titanium coatings

    Get PDF
    Three different surface treatments on a Ti6Al4V alloy have been in vitro tested for possible application in cementless joint prosthesis; all of them involve the novelty of using the Cold Spray technology for their deposition: (i) an as-sprayed highly rough titanium and, followed by the deposition of a thin hydroxyapatite layer with (ii) microcrystalline or (iii) nanocrystalline structure. Primary human osteoblasts extracted from knee were seeded onto surfaces and cell viability using MTS and LIFE/DEAD assays, osteoblasts differentiation by alkaline phosphatase (ALP) quantification as well as cell morphology were tested at 1, 7 and 14 days of cell culture. Different cell morphologies between titanium and hydroxyapatite surfaces were exhibited; at 1 day of cell culture, cells on the titanium coating were spread and flattened, expanding the filopodia actin filaments in all directions, while cells on the hydroxyapatite coatings showed round like-shape morphology due to a slower attachment. Higher cell viability was detected at all times of cell culture on titanium coating due to a better attachment at 1 day. However, from 7 days of cell culture, cells on hydroxyapatite showed good attachment onto surfaces and highly increased their proliferation, mostly on nanocrystalline, achieving similar cell viability levels than titanium coatings. ALP levels were significantly higher in titanium, in part, because of greatest cell number. Overall, the best cell functional results were obtained on titanium coatings whereas microcrystalline hydroxyapatite presented the worst cellular parameters. However, results indicate that nanocrystalline hydroxyapatite coatings may achieve promising results for the faster cell proliferation once cells are attached on the surface

    In-vitro study of hierarchical structures: Anodic oxidation and alkaline treatments onto highly rough titanium cold spray coatings for biomedical applications

    Get PDF
    Hierarchical structures were obtained applying two different nanotexturing surface treatments onto highly rough commercial pure titanium coatings by cold spray: (i) anodic oxidation and (ii) alkaline treatments. An extended surface characterization in terms of topography, composition, and wettability has been performed to understand how those parameters affect to cell response. Primary human osteoblasts extracted from knee were seeded onto the as-sprayed titanium surface before and after the nanotexturing treatments. Cell viability was tested by using MTS and LIVE/DEAD assays, as well as osteoblasts differentiation by alkaline phosphatase (ALP) quantification at 3 and 10 days of cell culture. The combination of micro-/nano-roughness results in a significantly increase of cell proliferation, as well as cell differentiation after 10 days of cell culture in comparison with the non-treated coatings

    Real-time protein and cell binding measurements on hydroxyapatite coatings.

    Get PDF
    Although a lot of in vitro and in vivo assays have been performed during the last few decades years for hydroxyapatite bioactive coatings, there is a lack of exploitation of real-time in vitro interaction measurements. In the present work, real-time interactions for a plasma sprayed hydroxyapatite coating were measured by a Multi-Parametric Surface Plasmon Resonance (MP-SPR), and the results were compared with standard traditional cell viability in vitro assays. MP-SPR is proven to be suitable not only for measurement of molecule-molecule interactions but also molecule-material interaction measurements and cell interaction. Although SPR is extensively utilized in interaction studies, recent research of protein or cell adsorption on hydroxyapatite coatings for prostheses applications was not found. The as-sprayed hydroxyapatite coating resulted in 62.4% of crystalline phase and an average thickness of 24 ± 6 Όm. The MP-SPR was used to measure lysozyme protein and human mesenchymal stem cells interaction to the hydroxyapatite coating. A comparison between the standard gold sensor and Hydroxyapatite (HA)-plasma coated sensor denoted a clearly favourable cell attachment on HA coated sensor as a significantly higher signal of cell binding was detected. Moreover, traditional cell viability and proliferation tests showed increased activity with culture time indicating that cells were proliferating on HA coating. Cells show homogeneous distribution and proliferation along the HA surface between one and seven days with no significant mortality. Cells were flattened and spread on rough surfaces from the first day, with increasing cytoplasmatic extensions during the culture time.The authors wish to thank the Generalitat de Catalunya for the project 2014 SGR 1558 and the University of Barcelona for the award of a scholarship that has allowed the development of this research. The authors thank the Adult Stem Cell Group, BioMediTech (University of Tampere, Tampere, Finland) for collaboration and providing the cells for the MP-SPR measurement. The authors wish to thank Department of Automation Science and Engineering (Tampere University of Technology, Tampere, Finland) and Niko Granqvist from BioNavis for their help related to MP-SPR measurements
    corecore