28 research outputs found

    Estudo metabólico com flúor-18-fluorodeoxiglicose no estadiamento e avaliação de massa residual ou recidiva no linfoma de Hodgkin

    Get PDF
    OBJECTIVE: The metabolic test using 18F-fluorodeoxyglucose is a useful tool for the management of patients with Hodgkin lymphoma, either for staging purposes or for the evaluation of suspicious masses that can frequently occur after treatment. The aim of the present study was to investigate the value of the 18F-fluorodeoxyglucose test performed with a dual-head coincident gamma camera (CGC-PET with fluorodeoxyglucose) for the staging and the detection of residual tumor of patients with Hodgkin lymphoma. METHODS: Thirty-eight consecutive patients were included in this retrospective study; the metabolic test comprising CGC-PET with FDG was done in 18 patients for staging work-up (Group 1), and the results were compared to conventional clinical staging procedures that included computed tomography scans and bone marrow biopsy. The remaining 20 patients were evaluated with CGC-PET with fluorodeoxyglucose due to the presence of residual masses or a new lesion (Group 2). RESULTS: The 18F-Fluorodeoxyglucose metabolic test, CGC-PET with fluorodeoxyglucose, upstaged 5 (27%) of the Group 1 patients and detected more lesions (45) than conventional methods of staging (33). Of the 20 patients in Group 2, 11 had positive18F-fluorodeoxyglucosetests, and a viable tumor was confirmed in 9 patients. Regarding the 9 patients with negative fluorodeoxyglucose metabolic tests, the 1-year probability of recurrence was 11.8%. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the CGC-PET with fluorodeoxyglucose test were 90%, 80%, 82%, 89%, and 85% respectively. CONCLUSIONS: The metabolic test comprising CGC-PET with fluorodeoxyglucose had a higher diagnostic accuracy than conventional methods in the staging of Hodgkin lymphoma and thus is a valuable noninvasive tool for the diagnosis of suspicious lesions.OBJETIVO: O estudo metabólico com 18F-fluorodeoxiglicose é uma ferramenta útil para o manejo de portadores de linfoma de Hodgkin, tanto como método auxiliar no estadiamento da doença, quanto na avaliação de massas suspeitas encontradas após tratamento. O objetivo deste estudo foi investigar o valor do estudo com 18F-fluorodeoxiglicose em gama câmara híbrida no estadiamento e na detecção de tumor residual em pacientes com linfoma de Hodgkin. MÉTODOS: Trinta e oito pacientes foram incluídos neste estudo retrospectivo, 18 foram avaliados com o estudo metabólico durante o estadiamento (Grupo 1), sendo os resultados do estudo comparados com os obtidos com o estadiamento convencional, que incluiu tomografia e biópsia de medula óssea. Os 20 pacientes restantes realizaram o estudo metabólico devido à presença de massa residual ou de nova lesão suspeita (Grupo 2). RESULTADOS: O estudo metabólico aumentou o estádio de cinco (27%) dos pacientes do Grupo 1 e pôde detectar mais lesões que os métodos convencionais de estadiamento (45 lesões detectadas com 18F-fluorodeoxiglicose versus 33 lesões métodos convencionais). Nos 20 pacientes do Grupo 2, 11 foram 18F-fluorodeoxiglicose positivos e tumor viável foi confirmado em 9 pacientes. Nos 9 pacientes com estudo metabólico negativo, a probabilidade de recidiva em um ano foi de 11.8%. A sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e a acurácia do estudo metabólico foram de 90%, 80%, 82%, 89% e 85% respectivamente. CONCLUSÕES: O estudo com 18F-fluorodeoxiglicose apresentou melhor acurácia que os métodos convencionais de estadiamento do Linfoma de Hodgkin e foi útil para o diagnóstico não-invasivo de lesões suspeitas

    Preoperative evaluation of cytologically indeterminate thyroid nodules with 18F-FDG PET

    Get PDF
    Esse artigo tem o objetivo de discutir o papel da tomografia por emissão de pósitrons (PET) com 18F-FDG na avaliação pré-operatória de pacientes com nódulos de tireóide com citologia indeterminada. Para o cálculo da sensibilidade, foram selecionados todos os estudos com pacientes com carcinoma de tireóide. Para o cálculo da especificidade, foram selecionados apenas estudos desenhados para avaliação dos pacientes com nódulos com citologia indeterminada. O achado de captação focal na PET-18F-FDG relacionou-se com a presença de carcinoma de tireóide na maioria dos estudos. A sensibilidade do exame foi bastante alta na detecção de malignidade tireoidiana, porém sua especificidade variou de 0% a 66%, sendo de 39% em estudo brasileiro. Concluindo, os estudos indicam que a PET-18F-FDG pode reduzir o número de tireoidectomias desnecessárias em pacientes com nódulos de tireóide com citologia indeterminada. Entretanto, o percentual relativamente elevado de resultados falso-positivos, o alto custo, a baixa disponibilidade do exame em países em desenvolvimento e a pouca experiência clínica ainda limitam o uso da PET-18F-FDG com essa finalidade.The aim of this article is to discuss the role of 18F-FDG Positron Emission Tomography (PET) in the preoperative evaluation of patients with cytologically indeterminate thyroid nodules. All studies with patients with thyroid cancer were selected to the calculation of sensitivity. Only studies aiming to evaluate patients with thyroid nodules whose cytological result was indeterminate were selected to establish the specificity. The finding of focal 18F-FDG uptake at PET was associated with the presence of thyroid malignancy in most of the studies. The sensitivity of the exam to the detection of thyroid malignancy was extremely high, but the specificity varied from 0 to 66%. In our experience, the specificity was 39%. In conclusion, the studies suggest that 18F-FDG PET can reduce the number of unnecessary thyroidectomies performed in patients with cytologically indeterminate thyroid nodules. However, the relatively high percentage of false positive results, the high costs, the low availability of this exam in developing countries and the low clinical experience still restrict the use of 18F-FDG PET when recommended with this aim

    Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world

    Get PDF
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection

    Apresentação

    No full text

    Metabolic test with fluorine-18-fluorodeoxyglucose in staging and detection of residual tumor or recurrence in Hodgkin lymphoma

    No full text
    OBJECTIVE: The metabolic test using 18F-fluorodeoxyglucose is a useful tool for the management of patients with Hodgkin lymphoma, either for staging purposes or for the evaluation of suspicious masses that can frequently occur after treatment. The aim of the present study was to investigate the value of the 18F-fluorodeoxyglucose test performed with a dual-head coincident gamma camera (CGC-PET with fluorodeoxyglucose) for the staging and the detection of residual tumor of patients with Hodgkin lymphoma. METHODS: Thirty-eight consecutive patients were included in this retrospective study; the metabolic test comprising CGC-PET with FDG was done in 18 patients for staging work-up (Group 1), and the results were compared to conventional clinical staging procedures that included computed tomography scans and bone marrow biopsy. The remaining 20 patients were evaluated with CGC-PET with fluorodeoxyglucose due to the presence of residual masses or a new lesion (Group 2). RESULTS: The 18F-Fluorodeoxyglucose metabolic test, CGC-PET with fluorodeoxyglucose, upstaged 5 (27%) of the Group 1 patients and detected more lesions (45) than conventional methods of staging (33). Of the 20 patients in Group 2, 11 had positive18F-fluorodeoxyglucosetests, and a viable tumor was confirmed in 9 patients. Regarding the 9 patients with negative fluorodeoxyglucose metabolic tests, the 1-year probability of recurrence was 11.8%. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the CGC-PET with fluorodeoxyglucose test were 90%, 80%, 82%, 89%, and 85% respectively. CONCLUSIONS: The metabolic test comprising CGC-PET with fluorodeoxyglucose had a higher diagnostic accuracy than conventional methods in the staging of Hodgkin lymphoma and thus is a valuable noninvasive tool for the diagnosis of suspicious lesions.OBJETIVO: O estudo metabólico com 18F-fluorodeoxiglicose é uma ferramenta útil para o manejo de portadores de linfoma de Hodgkin, tanto como método auxiliar no estadiamento da doença, quanto na avaliação de massas suspeitas encontradas após tratamento. O objetivo deste estudo foi investigar o valor do estudo com 18F-fluorodeoxiglicose em gama câmara híbrida no estadiamento e na detecção de tumor residual em pacientes com linfoma de Hodgkin. MÉTODOS: Trinta e oito pacientes foram incluídos neste estudo retrospectivo, 18 foram avaliados com o estudo metabólico durante o estadiamento (Grupo 1), sendo os resultados do estudo comparados com os obtidos com o estadiamento convencional, que incluiu tomografia e biópsia de medula óssea. Os 20 pacientes restantes realizaram o estudo metabólico devido à presença de massa residual ou de nova lesão suspeita (Grupo 2). RESULTADOS: O estudo metabólico aumentou o estádio de cinco (27%) dos pacientes do Grupo 1 e pôde detectar mais lesões que os métodos convencionais de estadiamento (45 lesões detectadas com 18F-fluorodeoxiglicose versus 33 lesões métodos convencionais). Nos 20 pacientes do Grupo 2, 11 foram 18F-fluorodeoxiglicose positivos e tumor viável foi confirmado em 9 pacientes. Nos 9 pacientes com estudo metabólico negativo, a probabilidade de recidiva em um ano foi de 11.8%. A sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e a acurácia do estudo metabólico foram de 90%, 80%, 82%, 89% e 85% respectivamente. CONCLUSÕES: O estudo com 18F-fluorodeoxiglicose apresentou melhor acurácia que os métodos convencionais de estadiamento do Linfoma de Hodgkin e foi útil para o diagnóstico não-invasivo de lesões suspeitas

    Terapia de ressincronização melhora a captação do MIBI-99mTc e a função cardíaca Cardiac resynchronization therapy improves the uptake of MIBI-99mTc and cardiac function

    No full text
    Este caso mostra a melhora proporcionada pela terapia de ressincronização cardíaca (TRC) sobre a perfusão miocárdica e o desempenho do ventrículo esquerdo (VE) avaliados pela cintilografia de perfusão miocárdica com MIBI-99mTc sincronizada ao eletrocardiograma. Paciente portadora de miocardiopatia dilatada idiopática, bloqueio de ramo esquerdo e insuficiência cardíaca refratária ao tratamento medicamentoso otimizado. Após TRC, foi observada melhora clínica, redução da duração do QRS e melhora na perfusão das paredes anterior e ântero-septal que se encontravam previamente hipoperfundidas. Houve também redução dos volumes diastólico e sistólico finais e aumento da fração de ejeção do VE.<br>This case shows the improvement promoted by cardiac resynchronization therapy (CRT) on myocardial perfusion and left ventricular (LV) performance assessed by gated myocardial perfusion scintigraphy. The patient had idiopathic dilated cardiomyopathy, left bundle branch block and severe heart failure despite optimized medical treatment. After CRT, clinical improvement, QRS reduction and improvement of previously hypoperfused anterior and septal walls were observed. There was also decrease in LV end-diastolic and systolic volumes and increase in LV ejection fraction

    2-&#091;18F&#093;-fluoro-2-deoxy-D-glucose positron-emission tomography is cost-effective in the initial staging of non-small cell lung cancer patients in Brazil

    No full text
    OBJETIVO: Comparar a acurácia e a custo-efetividade do estadiamento metabólico (EM) com o FDG-PET em relação ao estadiamento convencional (EC) no estadiamento inicial de pacientes com câncer de pulmão não pequenas células (CPNPC). MATERIAIS E MÉTODOS: Noventa e cinco pacientes com diagnóstico inicial de CPNPC foram estadiados antes do início do tratamento. Os resultados do EC e EM foram comparados quanto a definição do tratamento e incidência de toracotomia fútil em cada estratégia. RESULTADOS: O EM com FDG-PET classificou 48,4% dos pacientes como estádio mais avançado e 5,3% como menos avançado. O resultado do EM modificaria o tratamento em 41% dos pacientes. A toracotomia foi considerada fútil em 47% dos pacientes com EC e em 19% dos casos com EM. O custo das toracotomias fúteis em oito pacientes no EM foi de R79.720,enquantoem31pacientesnoECseriadeR 79.720, enquanto em 31 pacientes no EC seria de R 308.915. Apenas esta economia seria mais que suficiente para cobrir os custos de todos os exames de FDG-PET nos 95 pacientes (R126.350)oudeFDGPET/CT(R 126.350) ou de FDG-PET/CT (R 193.515). CONCLUSÃO: O EM com FDG-PET tem maior acurácia que o EC em pacientes com CPNPC. A FDG-PET e FDG-PET/CT são custo-efetivas e sua utilização se justifica economicamente na saúde pública no Brasil
    corecore