342 research outputs found

    Miniature proportional control valve with top-mounted piezo bimorph actuator with millisecond response time

    Get PDF
    In this paper we demonstrate the realization of a micro control valve with a top-mounted piezoelectric bimorph actuator, to obtain a high-bandwidth proportional control valve for gases in the range of several grams per hour. Dynamic fluidic and mechanical characterization shows that the valve is suitable for high-speed flow control with response times on the order of milliseconds. The microvalve contains an integrated capacitive displacement sensor for position-based control, which can be used to improve the control precision. The microvalve is realized in a straight-forward fabrication process based on a single SOI wafer. A high level of integration of the piezo actuator is achieved using a flexible silicone rubber support between the bimorph and the silicon. This leads to a small volume, high speed device

    A micro control valve with integrated capacitive sensing for ambulant blood pressure waveform monitoring

    Get PDF
    We have designed and fabricated the first single-wafer proportional micro control valve with built-in capacitive dis-placement sensing. The displacement sensor can facilitate high-speed active proportional control of gas flow through the valve. This is an essential requirement for non-invasive blood pressure waveform monitoring based on following the arte-rial pressure with a counter pressure. We demonstrate a near-linear relation between valve plate displacement and inverse capacitance. The valve shows monotonously increasing flow with decreasing capacitance and increasing pressure

    Car Driving Performance in Hemianopia:An On-Road Driving Study

    Get PDF
    PURPOSE. To study driving performance in people with homonymous hemianopia (HH) assessed in the official on-road test of practical fitness to drive by the Dutch driver's licensing authority (CBR).METHODS. Data were collected from a cohort (January 2010-July 2012) of all people with HH following the official relicensure trajectory at Royal Dutch Visio and the CBR in the Netherlands. Driving performance during the official on-road tests of practical fitness to drive was scored by professional experts on practical fitness to drive, using the visual impairments protocol and a standardized scoring of visual, tactical and operational aspects. Age ranged from 27 to 72 years (mean = 52, SD = 11.7) and time since onset of the visual field defect ranged from 6 to 41 months (mean = 15, SD = 7.5).RESULTS. Fourteen (54%) participants were judged as fit to drive. Besides poor visual scanning during driving, specific tactical, and operational weaknesses were observed in people with HH that were evaluated as unfit to drive. Results suggest that judgement on practical fitness to drive cannot be based on solely the visual field size. Visual scanning and operational handling of the car were found to be more impaired with longer time not driven, while such an effect was not found for tactical choices during driving.CONCLUSIONS. Training programs aimed at improving practical fitness to drive in people with HH should focus on improving both visual scanning, as well as driving aspects such as steering stability, speed adaptation, and anticipating environmental changes.</p

    Reliability of brain atrophy measurements in multiple sclerosis using MRI: an assessment of six freely available software packages for cross-sectional analyses

    Get PDF
    PURPOSE: Volume measurement using MRI is important to assess brain atrophy in multiple sclerosis (MS). However, differences between scanners, acquisition protocols, and analysis software introduce unwanted variability of volumes. To quantify theses effects, we compared within-scanner repeatability and between-scanner reproducibility of three different MR scanners for six brain segmentation methods. METHODS: Twenty-one people with MS underwent scanning and rescanning on three 3 T MR scanners (GE MR750, Philips Ingenuity, Toshiba Vantage Titan) to obtain 3D T1-weighted images. FreeSurfer, FSL, SAMSEG, FastSurfer, CAT-12, and SynthSeg were used to quantify brain, white matter and (deep) gray matter volumes both from lesion-filled and non-lesion-filled 3D T1-weighted images. We used intra-class correlation coefficient (ICC) to quantify agreement; repeated-measures ANOVA to analyze systematic differences; and variance component analysis to quantify the standard error of measurement (SEM) and smallest detectable change (SDC). RESULTS: For all six software, both between-scanner agreement (ICCs ranging 0.4–1) and within-scanner agreement (ICC range: 0.6–1) were typically good, and good to excellent (ICC > 0.7) for large structures. No clear differences were found between filled and non-filled images. However, gray and white matter volumes did differ systematically between scanners for all software (p < 0.05). Variance component analysis yielded within-scanner SDC ranging from 1.02% (SAMSEG, whole-brain) to 14.55% (FreeSurfer, CSF); and between-scanner SDC ranging from 4.83% (SynthSeg, thalamus) to 29.25% (CAT12, thalamus). CONCLUSION: Volume measurements of brain, GM and WM showed high repeatability, and high reproducibility despite substantial differences between scanners. Smallest detectable change was high, especially between different scanners, which hampers the clinical implementation of atrophy measurements

    Folate reference interval estimation in the Dutch general population

    Get PDF
    Background: Folate functions as an enzyme co-factor within the one-carbon metabolic pathway, providing key metabolites required for DNA synthesis and methylation. Hence, insufficient intake of folate can negatively affect health. As correct interpretation of folate status is dependent on a well-established reference interval, we set out to perform a new estimation following the restandardization of the Roche folate assay against the international folate standard. Materials and methods: The folate reference interval was estimated using samples obtained from the Dutch population-based Lifelines cohort. The reference interval was estimated using two methods: a nonparametric estimation combined with bootstrap resampling and by fitting the data to a gamma distribution. The lower reference limit was verified in a patient cohort by combined measurement of folate and homocysteine. Results: Dependent on the method used for estimation and in- or exclusion of individuals younger than 21 years of age, the lower reference limit ranged from 6.8 to 7.3 nmol/L and the upper reference limit ranged from 26 to 38.5 nmol/L. Applying a lower reference limit of 7.3 nmol/L resulted in the following percentage of folate deficiencies over a period of 12 months: general practitioner 15.5% (IQR 4.0%), general hospital 12.8% (IQR 5.3%), academic hospital 9.6% (IQR 4.3%). Conclusions: We estimated the folate reference interval in the Dutch general population which is not affected by a folic acid fortification program and verified the obtained lower reference limit by homocysteine measurements. Based on our results, we propose a folate reference interval independent of age of 7.3-38.5 nmol/

    Involvement of MicroRNAs in the Aging-Related Decline of CD28 Expression by Human T Cells

    Get PDF
    Loss of CD28 is a characteristic feature of T cell aging, but the underlying mechanisms of this loss are elusive. As differential expression of microRNAs (miRNAs) has been described between CD28+ and CD28- T cells, we hypothesized that altered miRNA expression contributes to the age-associated downregulation of CD28. To avoid the confounding effects of age-associated changes in the proportions of T cells at various differentiation stages in vivo, an experimental model system was used to study changes over time in the expression of miRNA associated with the loss of CD28 expression in monoclonal T cell populations at a lower or higher number of population doublings (PDs). This approach allows identification of age-associated miRNA expression changes in a longitudinal model. Results were validated in ex vivo samples. The cumulative number of PDs but not the age of the donor of the T cell clone was correlated with decreased expression of CD28. Principal component analysis of 252 expressed miRNAs showed clustering based on low and high PDs, irrespective of the age of the clone donor. Increased expression of miR-9-5p and miR-34a-5p was seen in clones at higher PDs, and miR-9-5p expression inversely correlated with CD28 expression in ex vivo sorted T-cells from healthy subjects. We then examined the involvement of miR-9-5p, miR-34a-5p, and the members of the miR-23a similar to 24-2 cluster, in which all are predicted to bind to the 3'UTR of CD28, in the IL-15-induced loss of CD28 in T cells. Culture of fresh naive CD28+ T cells in the presence of IL-15 resulted in a gradual loss of CD28 expression, while the expression of miR-9-5p, miR-34a-5p, and members of the miR-23a-24-2 cluster increased. Binding of miR-9-5p, miR-34a-5p, miR-24-3p, and miR-27- 3p to the 3'UTR of CD28 was studied using luciferase reporter constructs. Functional binding to the 3'UTR was shown for miR-24-3p and miR-27a-3p. Our results indicate involvement of defined miRNAs in T cells in relation to specific characteristics of T cell aging, i.e., PD and CD28 expression

    Vision-related fitness to drive mobility scooters:A practical driving test

    Get PDF
    Objective: To investigate practical fitness to drive mobility scooters, comparing visually impaired participants with healthy controls. Design: Between-subjects design. Subjects: Forty-six visually impaired (13 with very low visual acuity, 10 with low visual acuity, 11 with peripheral field defects, 12 with multiple visual impairment) and 35 normal-sighted controls. Methods: Participants completed a practical mobility scooter test-drive, which was recorded on video. Two independent occupational therapists specialized in orientation and mobility evaluated the videos systematically. Results: Approximately 90% of the visually impaired participants passed the driving test. On average, participants with visual impairments performed worse than normal-sighted controls, but were judged sufficiently safe. In particular, difficulties were observed in participants with peripheral visual field defects and those with a combination of low visual acuity and visual field defects. Conclusion: People with visual impairment are, in practice, fit to drive mobility scooters; thus visual impairment on its own should not be viewed as a determinant of safety to drive mobility scooters. However, special attention should be paid to individuals with visual field defects with or without a combined low visual acuity. The use of an individual practical fitness-to-drive test is advised

    Psychometric evaluation of the Mental Health Quality of Life (MHQoL) instrument in seven European countries

    Get PDF
    Introduction: To make efficient use of available resources, decision-makers in healthcare may assess the costs and (health) benefits of health interventions. For interventions aimed at improving mental health capturing the full health benefits is an important challenge. The Mental Health Quality of Life (MHQoL) instrument was recently developed to meet this challenge. Evaluating the pyschometric properties of this instrument in different contexts remains important. Methods: A psychometric evaluation of the MHQoL was performed using existing international, cross-sectional data with 7155 respondents from seven European countries (Denmark, France, Germany, Italy, Portugal, The Netherlands, Portugal and the United Kingdom). Reliability was examined by calculating Cronbach’s alpha, a measure of internal consistency of the seven MHQoL dimensions, and by examining the association of the MHQoL sum scores with the MHQoL-VAS scores. Construct validity was examined by calculating Spearman’s rank correlation coefficients between the MHQoL sum scores and EQ-5D index scores, EQ-VAS scores, EQ-5D anxiety/depression dimension scores, ICECAP-A index scores and PHQ-4 sum scores. Results: The MHQoL was found to have good internal consistency for all seven countries. The MHQoL sum score and the MHQoL-VAS had a high correlation. Spearman’s rank correlation coefficients were moderate to very high for all outcomes. Conclusion: Our results, based on data gathered in seven European countries, suggest that the MHQoL shows favourable psychometrical characteristics. While further validation remains important, the MHQoL may be a useful instrument in measuring mental health-related quality of life in the Western European context

    MycoBank gearing up for new horizons.

    Get PDF
    MycoBank, a registration system for fungi established in 2004 to capture all taxonomic novelties, acts as a coordination hub between repositories such as Index Fungorum and Fungal Names. Since January 2013, registration of fungal names is a mandatory requirement for valid publication under the International Code of Nomenclature for algae, fungi and plants (ICN). This review explains the database innovations that have been implemented over the past few years, and discusses new features such as advanced queries, registration of typification events (MBT numbers for lecto, epi- and neotypes), the multi-lingual database interface, the nomenclature discussion forum, annotation system, and web services with links to third parties. MycoBank has also introduced novel identification services, linking DNA sequence data to numerous related databases to enable intelligent search queries. Although MycoBank fills an important void for taxon registration, challenges for the future remain to improve links between taxonomic names and DNA data, and to also introduce a formal system for naming fungi known from DNA sequence data only. To further improve the quality of MycoBank data, remote access will now allow registered mycologists to act as MycoBank curators, using Citrix software
    • …
    corecore