20,887 research outputs found

    Boundary lubrication and thermal stability studies with five liquid lubricants in nitrogen to 400 C

    Get PDF
    Steel friction and wear tests in nitrogen with paraffinic resins, synthetic paraffinic oil, glycol, and ester lubricants including thermal stability at high temperature

    A comparison of measured and theoretical predictions for STS ascent and entry sonic booms

    Get PDF
    Sonic boom measurements have been obtained during the flights of STS-1 through 5. During STS-1, 2, and 4, entry sonic boom measurements were obtained and ascent measurements were made on STS-5. The objectives of this measurement program were (1) to define the sonic boom characteristics of the Space Transportation System (STS), (2) provide a realistic assessment of the validity of xisting theoretical prediction techniques, and (3) establish a level of confidence for predicting future STS configuration sonic boom environments. Detail evaluation and reporting of the results of this program are in progress. This paper will address only the significant results, mainly those data obtained during the entry of STS-1 at Edwards Air Force Base (EAFB), and the ascent of STS-5 from Kennedy Space Center (KSC). The theoretical prediction technique employed in this analysis is the so called Thomas Program. This prediction technique is a semi-empirical method that required definition of the near field signatures, detailed trajectory characteristics, and the prevailing meteorological characteristics as an input. This analytical procedure then extrapolates the near field signatures from the flight altitude to an altitude consistent with each measurement location

    Fabrication and wear test of a continuous fiber/particulate composite total surface hip replacement

    Get PDF
    Continuous fiber woven E-glass composite femoral shells having the ame elastic properties as bone were fabricated. The shells were then encrusted with filled epoxy wear resistant coatings and run dry against ultrahigh molecular weight polyethylene acetabular cups in 42,000 and 250,000 cycle were tests on a total hip simulator. The tribological characteristics of these shells atriculating with the acetabular cups are comparable to a vitallium bal articulating with an ultrahigh molecular weight polyethylene cup

    Study of solution procedures for nonlinear structural equations

    Get PDF
    A method for the redution of the cost of solution of large nonlinear structural equations was developed. Verification was made using the MARC-STRUC structure finite element program with test cases involving single and multiple degrees of freedom for static geometric nonlinearities. The method developed was designed to exist within the envelope of accuracy and convergence characteristic of the particular finite element methodology used

    Tribological characteristics of a composite total-surface hip replacement

    Get PDF
    Continuous fiber, woven E glass composite femoral shells having the same elastic properties as bone were fabricated. The shells were then encrusted with filled epoxy wear resistant coatings and run dry against ultrahigh molecular weight polyethylene acetabular cups in 42,000 and 250,000 cycle wear tests on a total hip simulator. The tribological characteristics of these continuous fiber particulate composite femoral shells articulating with ultrahigh molecular weight polyethylene acetabular cups were comparable to those of a vitallium ball articulating with an ultrahigh molecular weight polyethylene acetabular cup

    Correlation of predicted and measured sonic boom characteristics from the reentry of STS-1 orbiter

    Get PDF
    Characteristics from sonic boom pressure signatures recorded at 11 locations during reentry of the Space Shuttle Orbiter Columbia are correlated with characteristics of wind tunnel signatures extrapolated from flight altitudes for Mach numbers ranging from 1.23 to 5.87. The flight pressure signature were recorded by microphones positioned at two levels near the descent groundtrack along the California corridor. The wind tunnel signatures used in theoretical predictions were measured using a 0.0041-scale model Orbiter. The mean difference between all measured and predicted overpressures is 12 percent from measured levels. With one exception, the flight signatures are very similar to theoretical n-waves

    Effect of sterilization irradiation on friction and wear of ultrahigh-molecular-weight polyethylene

    Get PDF
    The effect of sterilization gamma irradiation on the friction and wear properties of ultrahigh molecular weight polyethylene (UHMWPE) sliding against 316L stainless steel in dry air at 23 C was determined. A pin-on-disk apparatus was used. Experimental conditions included a 1-kilogram load, a 0.061- to 0.27-meter-per-second sliding velocity, and a 32000- to 578000-meter sliding distance. Although sterilization doses of 2.5 and 5.0 megarads greatly altered the average molecular weight and the molecular weight distribution, the friction and wear properties of the polymer were not significantly changed

    Preliminary sonic boom correlation of predicted and measured levels for STS-1 entry

    Get PDF
    A preliminary analysis correlating peaks from sonic boom pressure signatures recorded during the descent trajectory of the Orbiter Columbia, which landed in the dry lake bed at Edwards Air Force Base (EAFB), California, with measured wind tunnel signatures extrapolated from flight altitudes to the ground has been made for Mach numbers ranging from 1.3 to 6. The flight pressure signatures were recorded by microphones positioned at ground level near the groundtrack, whereas the wind tunnel signatures were measured during a test of a 0.0041-scale model Orbiter. The agreement between overpressure estimates based on wind tunnel data using preliminary flight trajectory data and oscillograph traces from ground measurements appears reasonable at this time for the range of Mach numbers considered. More detailed studies using final flight trajectory data and digitized ground measured data will be performed

    Clevis design for compact tension specimens used in plane-strain fracture toughness testing

    Get PDF
    Friction effects in round hole clevis for testing compact tension fracture toughness specimen
    corecore