6 research outputs found

    Effect of mattress deflection on CPR quality assessment for older children and adolescents

    Get PDF
    Appropriate chest compression (CC) depth is associated with improved CPR outcome. CCs provided in hospital are often conducted on a compliant mattress. The objective was to quantify the effect of mattress compression on the assessment of CPR quality in children. Methods: A force and deflection sensor (FDS) was used during CPR in the Pediatric Intensive Care Unit and Emergency Department of a children's hospital. The sensor was interposed between the chest of the patient and hands of the rescuer and measured CC depth. Following CPR event, each event was reconstructed with a manikin and an identical mattress/backboard/patient configuration. CCs were performed using FDS on the sternum and a reference accelerometer attached to the spine of the manikin, providing a means to Calculate the mattress deflection. Results: Twelve CPR events with 14,487 CC (11 patients, median age 14.9 years) were recorded and reconstructed: 9 on ICU beds (9296 CC), 3 on stretchers (5191 CC). Measured mean CC depth during CPR was 47 +/- 8 mm on ICU beds, and 45 +/- 7 mm on stretcher beds with overestimation of 13 +/- 4 mm and 4 +/- 1 mm, respectively, due to mattress compression. After adjusting for this, the proportion of CC that met the CPR guidelines decreased from 88.4 to 31.8% on ICU beds (p < 0.001), and 86.3 to 64.7% on stretcher (p < 0.001 The proportion of appropriate depth CC was significantly smaller on ICU beds (p < 0.001). Conclusion: CC conducted on a non-rigid surface may not be deep enough. FDS may overestimate CC depth by 28% on ICU beds, and 10% on stretcher beds

    Effect of mattress deflection on CPR quality assessment for older children and adolescents

    Get PDF
    Appropriate chest compression (CC) depth is associated with improved CPR outcome. CCs provided in hospital are often conducted on a compliant mattress. The objective was to quantify the effect of mattress compression on the assessment of CPR quality in children. Methods: A force and deflection sensor (FDS) was used during CPR in the Pediatric Intensive Care Unit and Emergency Department of a children's hospital. The sensor was interposed between the chest of the patient and hands of the rescuer and measured CC depth. Following CPR event, each event was reconstructed with a manikin and an identical mattress/backboard/patient configuration. CCs were performed using FDS on the sternum and a reference accelerometer attached to the spine of the manikin, providing a means to Calculate the mattress deflection. Results: Twelve CPR events with 14,487 CC (11 patients, median age 14.9 years) were recorded and reconstructed: 9 on ICU beds (9296 CC), 3 on stretchers (5191 CC). Measured mean CC depth during CPR was 47 +/- 8 mm on ICU beds, and 45 +/- 7 mm on stretcher beds with overestimation of 13 +/- 4 mm and 4 +/- 1 mm, respectively, due to mattress compression. After adjusting for this, the proportion of CC that met the CPR guidelines decreased from 88.4 to 31.8% on ICU beds (p < 0.001), and 86.3 to 64.7% on stretcher (p < 0.001 The proportion of appropriate depth CC was significantly smaller on ICU beds (p < 0.001). Conclusion: CC conducted on a non-rigid surface may not be deep enough. FDS may overestimate CC depth by 28% on ICU beds, and 10% on stretcher beds

    A sternal accelerometer does not impair hemodynamics during piglet CPR

    No full text
    To determine whether the residual weight of a 260 g sternal accelerometer/force feedback device (AFFD) adversely affects hemodynamics during cardiopulmonary resuscitation in a piglet model of ventricular fibrillation cardiac arrest

    Leaning during chest compressions impairs cardiac output and left ventricular myocardial blood flow in piglet cardiac arrest

    No full text
    Complete recoil of the chest wall between chest compressions during cardiopulmonary resuscitation is recommended, because incomplete chest wall recoil from leaning may decrease venous return and thereby decrease blood flow. We evaluated the hemodynamic effect of 10% or 20% lean during piglet cardiopulmonary resuscitation
    corecore