257 research outputs found

    Fighting Oxidative Stress with Sulfur:Hydrogen Sulfide in the Renal and Cardiovascular Systems

    Get PDF
    Hydrogen sulfide (H2S) is an essential gaseous signaling molecule. Research on its role in physiological and pathophysiological processes has greatly expanded. Endogenous enzymatic production through the transsulfuration and cysteine catabolism pathways can occur in the kidneys and blood vessels. Furthermore, non-enzymatic pathways are present throughout the body. In the renal and cardiovascular system, H2S plays an important role in maintaining the redox status at safe levels by promoting scavenging of reactive oxygen species (ROS). H2S also modifies cysteine residues on key signaling molecules such as keap1/Nrf2, NF kappa B, and HIF-1 alpha, thereby promoting anti-oxidant mechanisms. Depletion of H2S is implicated in many age-related and cardiorenal diseases, all having oxidative stress as a major contributor. Current research suggests potential for H2S-based therapies, however, therapeutic interventions have been limited to studies in animal models. Beyond H2S use as direct treatment, it could improve procedures such as transplantation, stem cell therapy, and the safety and efficacy of drugs including NSAIDs and ACE inhibitors. All in all, H2S is a prime subject for further research with potential for clinical use

    Discrepancies between transcutaneous and estimated glomerular filtration rates in rats with chronic kidney disease

    Get PDF
    Accurate assessment of the glomerular filtration rate (GFR) is crucial for researching kidney disease in rats. Although validation of methods that assess GFR is crucial, large-scale comparisons between different methods are lacking. Both transcutaneous GFR (tGFR) and a newly developed estimated GFR (eGFR) equation by our group provide a low-invasive approach enabling repeated measurements. The tGFR is a single bolus method using FITC-labeled sinistrin to measure GFR based on half-life of the transcutaneous signal, whilst the eGFR is based on urinary sinistrin clearance. Here, we retrospectively compared tGFR, using both 1- and 3- compartment models (tGFR_1c and tGFR_3c, respectively) to the eGFR in a historic cohort of 43 healthy male rats and 84 male rats with various models of chronic kidney disease. The eGFR was on average considerably lower than tGFR-1c and tGFR-3c (mean differences 855 and 216 μL/min, respectively) and only 20 and 47% of measurements were within 30% of each other, respectively. The relative difference between eGFR and tGFR was highest in rats with the lowest GFR. Possible explanations for the divergence are problems inherent to tGFR, such as technical issues with signal measurement, description of the signal kinetics, and translation of half-life to tGFR, which depends on distribution volume. The unknown impact of isoflurane anesthesia used in determining mGFR remains a limiting factor. Thus, our study shows that there is a severe disagreement between GFR measured by tGFR and eGFR, stressing the need for more rigorous validation of the tGFR and possible adjustments to the underlying technique.</p

    Discrepancies between transcutaneous and estimated glomerular filtration rates in rats with chronic kidney disease

    Get PDF
    Accurate assessment of the glomerular filtration rate (GFR) is crucial for researching kidney disease in rats. Although validation of methods that assess GFR is crucial, large-scale comparisons between different methods are lacking. Both transcutaneous GFR (tGFR) and a newly developed estimated GFR (eGFR) equation by our group provide a low-invasive approach enabling repeated measurements. The tGFR is a single bolus method using FITC-labeled sinistrin to measure GFR based on half-life of the transcutaneous signal, whilst the eGFR is based on urinary sinistrin clearance. Here, we retrospectively compared tGFR, using both 1- and 3- compartment models (tGFR_1c and tGFR_3c, respectively) to the eGFR in a historic cohort of 43 healthy male rats and 84 male rats with various models of chronic kidney disease. The eGFR was on average considerably lower than tGFR-1c and tGFR-3c (mean differences 855 and 216 μL/min, respectively) and only 20 and 47% of measurements were within 30% of each other, respectively. The relative difference between eGFR and tGFR was highest in rats with the lowest GFR. Possible explanations for the divergence are problems inherent to tGFR, such as technical issues with signal measurement, description of the signal kinetics, and translation of half-life to tGFR, which depends on distribution volume. The unknown impact of isoflurane anesthesia used in determining mGFR remains a limiting factor. Thus, our study shows that there is a severe disagreement between GFR measured by tGFR and eGFR, stressing the need for more rigorous validation of the tGFR and possible adjustments to the underlying technique.</p

    Exenatide twice-daily does not affect renal function or albuminuria compared to titrated insulin glargine in patients with type 2 diabetes mellitus : A post-hoc analysis of a 52-week randomised trial

    Get PDF
    Aims: To compare the effects of long-term treatment with the GLP-1RA exenatide twicedaily versus titrated insulin glargine (iGlar) on renal function and albuminuria in type 2 diabetes (T2DM) patients. Methods: We post-hoc evaluated renal outcome-data of 54 overweight T2DM patients (mean +/- SD age 60 +/- 8 years, HbA1c 7.5 +/- 0.9%, eGFR 86 +/- 16 mL/min/1.73m(2), median [IQR] urinary albumin-to-creatinine-ratio (UACR) 0.75 [0.44-1.29] mg/mmol) randomised to exenatide 10 mg twice-daily or titrated iGlar on-top-of metformin for 52-weeks. Renal efficacy endpoints were change in creatinine clearance (CrCl) and albuminuria (urinary albuminexcretion [UAE] and UACR) based on 24-h urines, collected at baseline and Week-52. eGFR and exploratory endpoints were collected throughout the intervention-period, and after a 4-week wash-out. Results: HbA1c-reductions were similar with exenatide (mean +/- SEM -0.80 +/- 0.10%) and iGlar (-0.79 +/- 0.14%; treatment-difference 0.02%; 95% CI - 0.31 to 0.42%). Change from baseline to Week-52 in CrCl, UAE or UACR did not statistically differ; only iGlar reduced albuminuria (P <0.05; within-group). eGFR decreased from baseline to Week-4 with exenatide (-3.9 +/- 2.1 mL/min/1.73 m(2); P = 0.069) and iGlar (-2.7 +/- 1.2 mL/min/1.73 m(2); P = 0.034), without treatment-differences in ensuing trajectory. Exenatide versus iGlar reduced bodyweight (-5.4 kg; 2.9-7.9; P <0.001), but did not affect blood pressure, lipids or plasma uric acid. Conclusions: Among T2DM patients without overt nephropathy, one-year treatment with exenatide twice-daily does not affect renal function-decline or onset/progression of albuminuria compared to titrated iGlar. (C) 2019 Elsevier B.V. All rights reserved.Peer reviewe

    Reduced nitric oxide bioavailability impairs myocardial oxygen balance during exercise in swine with multiple risk factors

    Get PDF
    In the present study, we tested the hypothesis that multiple risk factors, including diabetes mellitus (DM), dyslipidaemia and chronic kidney disease (CKD) result in a loss of nitric oxide (NO) signalling, thereby contributing to coronary microvascular dysfunction. Risk factors were induced in 12 female swine by intravenous streptozotocin injections (DM), a high fat diet (HFD) and renal artery embolization (CKD). Female healthy swine (n = 13) on normal diet served as controls (Normal). After 5 months, swine were chronically instrumented and studied at rest and during exercise. DM + HFD + CKD swine demonstrated significant hyperglycaemia, dyslipidaemia and impaired kidney function compared to Normal swine. These risk factors were accompanied by coronary microvascular endothelial dysfunction both in vivo and in isolated small arteries, due to a reduced NO bioavailability, associated with perturbations in myocardial oxygen balance at rest and during exercise. NO synthase inhibition caused coronary microvascular constriction in exercising Normal swine, but had no effect in DM + HFD + CKD animals, while inhibition of phosphodiesterase 5 produced similar vasodilator responses in both groups, indicating that loss of NO bioavailability was principally responsible for the observed coronary microvascular dysfunction. This was associated with an increase in myocardial 8-isoprostane levels and a decrease in antioxidant capacity, while antioxidants restored the vasodilation to bradykinin in isolated coronary small arteries, suggesting that oxidative stress was principally responsible for the reduced NO bioavailability. In conclusion, five months of combined exposure to DM + HFD + CKD produces coronary endothelial dysfunction due to impaired NO bioavailability, resulting in impaired myocardial perfusion at rest and during exercise.</p

    Whole-body insulin clearance in people with type 2 diabetes and normal kidney function:Relationship with glomerular filtration rate, renal plasma flow, and insulin sensitivity

    Get PDF
    OBJECTIVE: Kidney insulin clearance, proposed to be the main route of extra-hepatic insulin clearance, occurs in tubular cells following glomerular filtration and peritubular uptake, a process that may be impaired in people with type 2 diabetes (T2D) and/or impaired kidney function. Human studies that investigated kidney insulin clearance are limited by the invasive nature of the measurement. Instead, we evaluated relationships between whole-body insulin clearance, and gold-standard measured kidney function and insulin sensitivity in adults with T2D and normal kidney function. RESEARCH DESIGN AND METHODS: We determined insulin, inulin/iohexol and para-aminohippuric acid (PAH) clearances during a hyperinsulinemic-euglycemic clamp to measure whole-body insulin clearance and kidney function. Insulin sensitivity was expressed by glucose infusion rate (M value). Associations between whole-body insulin clearance, kidney function and insulin sensitivity were examined using univariable and multivariable linear regressions models. RESULTS: We investigated 44 predominantly male (77%) T2D adults aged 63 ± 7, with fat mass 34.5 ± 9 kg, lean body mass 63.0 ± 11.8 kg, and HbA1c 7.4 ± 0.6%. Average whole-body insulin clearance was 1188 ± 358 mL/min. Mean GFR was 110 ± 22 mL/min, mean ERPF 565 ± 141 mL/min, and M value averaged 3.9 ± 2.3 mg/min. Whole-body insulin clearance was positively correlated with lean body mass, ERPF and insulin sensitivity, but not with GFR. ERPF explained 6% of the variance when entered in a nested multivariable linear regression model op top of lean body mass (25%) and insulin sensitivity (15%). CONCLUSIONS: In adults with T2D and normal kidney function, whole-body insulin clearance was predicted best by lean body mass and insulin sensitivity, and to a lesser extent by ERPF. GFR was not associated with whole-body insulin clearance. In contrast to prior understanding, this suggests that in this population kidney insulin clearance may not play such a dominant role in whole-body insulin clearance

    In vitro efficacy and safety of a system for sorbent-assisted peritoneal dialysis

    Get PDF
    In vitro efficacy and safety of a system for sorbent-assisted peritoneal dialysis. Am J Physiol Renal Physiol 319: F162-F170, 2020. First published June 1, 2020; doi:10.1152/ajprenal. 00079.2020.-A system for sorbent-assisted peritoneal dialysis (SAPD) was designed to continuously recirculate dialysate via a tidal mode using a single lumen peritoneal catheter with regeneration of spent dialysate by means of sorbent technology. We hypothesize that SAPD treatment will maintain a high plasma-to-dialysate concentration gradient and increase the mass transfer area coefficient of solutes. Thereby, the SAPD system may enhance clearance while reducing the number of exchanges. Application is envisaged at night as a bedside device (12 kg, nighttime system). A wearable system (2.0 kg, daytime system) may further enhance clearance during the day. Urea, creatinine, and phosphate removal were studied with the daytime and nighttime system (n = 3 per system) by recirculating 2 liters of spent peritoneal dialysate via a tidal mode (mean flow rate: 50 and 100 mL/min, respectively) for 8 h in vitro. Time-averaged plasma clearance over 24 h was modeled assuming one 2 liter exchange/day, an increase in mass transfer area coefficient, and 0.9 liters ultrafiltration/day. Urea, creatinine, and phosphate removal was 33.2 ± 4.1, 5.3 ± 0.5, and 6.2 ± 1.8 mmol, respectively, with the daytime system and 204 ± 28, 10.3 ± 2.4, and 11.4 ± 2.1 mmol, respectively, with the nighttime system. Time-averaged plasma clearances of urea, creatinine and phosphate were 9.6 ± 1.1, 9.6 ± 1.7, and 7.0 ± 0.9 mL/min, respectively, with the nighttime system and 10.8 ± 1.1, 13.4 ± 1.8, and 9.7 ± 1.6 mL/min, respectively, with the daytime and nighttime system. SAPD treatment may improve removal of uremic toxins compared with conventional peritoneal dialysis, provided that peritoneal mass transport will increase
    corecore